Water removal in MR spectroscopic imaging with L2 regularization
- 31 May 2019
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 82 (4) , 1278-1287
Abstract
Purpose: An L2‐regularization based postprocessing method is proposed and tested for removal of residual or unsuppressed water signals in proton MR spectroscopic imaging (MRSI) data recorded from the human brain at 3T.Methods: Water signals are removed by implementation of the L2 regularization using a synthesized water‐basis matrix that is orthogonal to metabolite signals of interest in the spectral dimension. Simulated spectra with variable water amplitude and in vivo brain MRSI datasets were used to demonstrate the proposed method. Results were compared with two commonly‐used postprocessing methods for removing water signals.Results: The L2 method yielded metabolite signals that were close to true values for the simulated spectra. Residual/unsuppressed water signals in human brain short‐ and long‐echo time MRSI datasets were efficiently removed by the proposed method allowing good quality metabolite maps to be reconstructed with minimized contamination from water signals. Significant differences of the creatine signal were observed between brain long‐echo time MRSI without and with water saturation, attributable to the previously described magnetization transfer effect.Conclusions: With usage of a synthesized water matrix generated based on reasonable prior knowledge about water and metabolite resonances, the L2 method is shown to be an effective way to remove water signals from MRSI of the human brain.Keywords
Funding Information
- National Natural Science Foundation of China (11761141010)
This publication has 43 references indexed in Scilit:
- Lipid suppression in CSI with spatial priors and highly undersampled peripheral k‐spaceMagnetic Resonance in Medicine, 2012
- Composition of adipose tissue and marrow fat in humans by 1H NMR at 7 TeslaJournal of Lipid Research, 2008
- The rapid and automatic combination of proton MRSI data using multi-channel coils without water suppressionMagnetic Resonance Imaging, 2007
- Magnetization transfer effect on the creatine methyl resonance studied by CW off‐resonance irradiation in human skeletal muscle on a clinical MR systemMagnetic Resonance in Medicine, 2003
- Comparison of inversion recovery preparation schemes for lipid suppression in 1H MRSI of human brainMagnetic Resonance in Medicine, 2003
- A Novel Detection–Estimation Scheme for Noisy NMR Signals: Applications to Delayed Acquisition DataJournal of Magnetic Resonance, 1997
- SVD-based quantification of magnetic resonance signalsJournal of Magnetic Resonance (1969), 1992
- Improved solvent suppression in one- and two-dimensional NMR spectra by convolution of time-domain dataJournal of Magnetic Resonance (1969), 1989
- Improved algorithm for noniterative time-domain model fitting to exponentially damped magnetic resonance signalsJournal of Magnetic Resonance (1969), 1987
- A simple method for suppressing dispersion-mode contributions in NMR spectra: The “pseudo echo”Journal of Magnetic Resonance (1969), 1981