Central Vein Stenosis or Occlusion Associated with Cardiac Rhythm Management Device Leads in Hemodialysis Patients with Ipsilateral Arteriovenous Access: A Retrospective Study of Treatment Using Stents or Stent-Grafts
- 22 July 2010
- journal article
- research article
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 11 (4) , 293-302
Abstract
Purpose: Symptomatic central vein stenosis commonly occurs when cardiac rhythm management device (CRMD) leads are placed via the subclavian vein ipsilateral to arteriovenous (AV) hemodialysis (HD) access. The purposes of this study were to determine the outcomes, complications, and patency following stenting of CRMD lead-associated central vein stenosis or occlusion, and to determine the effect of stents on CRMD function. Methods: Fourteen HD patients with AV access and an ipsilateral CRMD were treated with stents for symptomatic central vein stenosis or occlusion following inadequate response to angioplasty from January 2005 to December 2009. Subsequent access interventions, complications, and outcomes were reviewed retrospectively. Cardiology records were examined to assess CRMD function. Results: Treatment of stenosis or occlusion with angioplasty and stenting resulted in 100% procedural success and no complications. At 6 and 12 months, respectively, primary patency rates were 45.5% and 9.0%; primary-assisted patency rates were 90.9% and 80.0%; secondary patency rates were 100% and 90.0%. There were 42 repeat interventions performed in 12 patients; five received additional stents. The mean number of subsequent interventions was 3.2 per patient (2.1 per patient-year). All CRMD testing demonstrated normal function with no device or lead failure. Seven of the 14 subjects died resulting in a 35.3% annual mortality rate. No deaths were attributable to dysrhythmia or CRMD failure and no patient required CRMD removal or exchange. Conclusions: Placement of stents for CRMD lead-associated stenosis or occlusion yields high success and low complication rates with no effect on CRMD function. Patency rates are similar to those reported in other series of central venous stents.Keywords
This publication has 40 references indexed in Scilit:
- ASDIN: Patency Rates for Angioplasty in the Treatment of Pacemaker‐Induced Central Venous Stenosis in Hemodialysis Patients: Results of a Multi‐Center StudySeminars in Dialysis, 2009
- Transiliac ICD implantation: Defibrillation vector flexibility produces consistent successHeart Rhythm, 2009
- Stent Placement in Hemodialysis AccessClinical Journal of the American Society of Nephrology, 2009
- Right Pectoral Implantable Cardioverter Defibrillators: Role of the Proximal (SVC) CoilPacing and Clinical Electrophysiology, 2008
- Long-term outcomes of primary angioplasty and primary stenting of central venous stenosis in hemodialysis patientsJournal of Vascular Surgery, 2007
- Predictors of venous obstruction following pacemaker or implantable cardioverter-defibrillator implantation: a contrast venographic study on 100 patients admitted for generator change, lead revision, or device upgradeEP Europace, 2007
- Renal dialysis as a risk factor for appropriate therapies and mortality in implantable cardioverter-defibrillator recipientsHeart Rhythm, 2006
- Percutaneous treatment of superior vena cava obstruction following transvenous device implantationCatheterization and Cardiovascular Interventions, 2005
- Percutaneous Treatment for Pacemaker‐Associated Superior Vena Cava SyndromePacing and Clinical Electrophysiology, 2002
- Subclavian Vein Stenosis, Permanent Cardiac Pacemakers and the Haemodialysed PatientNephron, 1991