Right Pectoral Implantable Cardioverter Defibrillators: Role of the Proximal (SVC) Coil
- 25 July 2008
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 31 (8) , 1025-1035
Abstract
Introduction: Increased defibrillation thresholds (DFTs) with right active pectoral implantable cardioverter defibrillators (ICDs) and/or right proximal coils (SVC) are attributed to poorer vector. However, SVC affects impedance, current flow, and shock waveform phase duration (PD), which exert independent DFT effects. Objective: Compare DFTs and shock characteristics in SVC On with SVC Off in right ICDs. Methods and Results : DFT+ testing (n = 42, 62% males, 62 ±15 years, left ventricular ejection fraction (LVEF) 26 ± 11%, ischemic cardiomyopathy 65%, amiodarone 26%) revealed >20% incidence of high DFT (>20J) . Dilated cardiomyopathy and amiodarone increased DFT. Individual impedance variability (25–74 Ω) generated a wide PD range (2.6–8.7 ms). Overall, SVC On reduced impedance by 33% (from 54 ± 10 to 35 ± 5Ω, P< 0.0001), and shortened PD (from 5.45 ± 1.20 to 3.67 ± 0.74 ms, P< 0.01). SVC On affected DFTs in 19/42 (45%) patients. SVC On was beneficial in 12/19. PD shortened but current flow remained unaltered. (In these, SVC Off impedance was >45Ω and PD >5 ms.) SVC On was detrimental in 7/19 despite increasing current flow. In these, PD shortened excessively (median 2.9 ms) because impedance was low (31 ± 4Ω). In 3/6 cases with DFTs >20 J in both SVC On and Off, PD optimization reduced DFT. Overall, selection of best SVC configuration or deliberate PD programming yielded DFTs ≤20 J in >90% patients, reducing need for system modification to Conclusions : Right pectoral active ICDs have high DFTs. The SVC coil may be detrimental when pulse waveform excessively shortens. Noninvasive maneuvers, for example, SVC and waveform optimization, may improve DFT.Keywords
This publication has 35 references indexed in Scilit:
- Optimization of superior vena cava coil position and usage for transvenous defibrillationHeart Rhythm, 2008
- Achieving Sufficient Safety Margins with Fixed Duration Waveforms and the Use of Multiple Time ConstantsPacing and Clinical Electrophysiology, 2007
- Benefit of millisecond waveform durations for patients with high defibrillation thresholdsHeart Rhythm, 2006
- High Defibrillation Thresholds in Transvenous Biphasic Implantable Defibrillators:Pacing and Clinical Electrophysiology, 2003
- Dual-coil vs single-coil active pectoral implantable defibrillator lead systems: defibrillation energy requirements and probability of defibrillation success at multiples of the defibrillation energy requirementsEP Europace, 2001
- Comparison of Right– and Left–Sided Pectoral Implantation Parameters with the Jewel Active Can CardiodefibrillatorPacing and Clinical Electrophysiology, 1998
- Right Side Implant of the Unipolar Single Lead Defihrillation SystemPacing and Clinical Electrophysiology, 1997
- Optimal electrode position for transvenous defibrillation: A prospective randomized studyJACC, 1996
- The Left Subclavian Vein as an Alternative Site for Implantation of the Second Defibrillation LeadPacing and Clinical Electrophysiology, 1995
- Defibrillation Threshold Testing and Other Practices Related to AICD Implantation: Do All Roads Lead to Rome?Pacing and Clinical Electrophysiology, 1989