As the market for minimally invasive procedures developed rapidly, there was an increase in the demand for high-precision, high-performance catheter fabrication technology. Sheath and dilator tubes are essential intervention devices for procedures, in which catheters are used and require precise dimensional accuracy, and uniform roundness and surface roughness. Polyethylene is used in sheath and dilator limitation for processability, which causes low melt flow index and side effects. Therefore, in the extrusion process using polyethylene, it is important to study the manufacturing of tubes with improved roundness and surface roughness. In this study, we proposed a calibrator for precise production with an aim to manufacture 5Fr micro-puncture tubes, and studied the changes in the roundness and surface roughness of tubes by changing the cooling water temperature and water disk thickness. As a result, it was found that the cooling water temperature and wafer disk thickness had an effect on the roundness and surface roughness, and the roundness had an effect on the formation of the wall thickness. Therefore, these experimental results were used as a study for the production of improved Sheath and Dilator tubes.Keywords
Funding Information
- Kumoh National Institute of Technology (202001390001)
This publication has 13 references indexed in Scilit:
- Study on Preparation of Ultra-High-Molecular-Weight Polyethylene Pipe of Good Thermal-Mechanical Properties Modified with Organo-Montmorillonite by Screw ExtrusionMaterials, 2020
- Extrusion Dies for Plastics and Rubber2016
- Extrudate swell of a high-density polyethylene melt: II. Modeling using integral and differential constitutive equationsJournal of Non-Newtonian Fluid Mechanics, 2015
- Design of complex profile extrusion dies through numerical modelingJournal of Non-Newtonian Fluid Mechanics, 2013
- Minimally invasive transradial intervention using sheathless standard guiding cathetersCatheterization and Cardiovascular Interventions, 2011
- Use of the sheathless guide catheter during routine transradial percutaneous coronary intervention: A feasibility studyCatheterization and Cardiovascular Interventions, 2010
- Surface modification of a biomedical polyethylene terephthalate (PET) by air plasmaApplied Surface Science, 2009
- The Medical Device R&D Handbook2005
- A simple way to suppress surface defects in the processing of polyethyleneJournal of Non-Newtonian Fluid Mechanics, 2004
- Swell and distortions of high‐density polyethylene extruded through capillary diesPolymer Engineering & Science, 1996