Woojin Kim has a total of 88 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Binary-Crosslinked Alginate/Zwitterionic Interpenetrating Polymer Network Coatings for Lubricious and Antifouling Urinary Catheters

    by Young Ho Seo, Dong Uk Lee, Ji Ho Choi, Jeong Sang Son, Kang Bin Kim, Woojin Kim, Dong Yun Lee, Dong Yun Choi

    Hydrophilic hydrogel coatings can mitigate catheter-associated infections and friction-induced mucosal trauma during urinary catheterization by providing hydration-driven lubrication and antifouling surfaces. Here, we report an alginate/sulfobetaine methacrylate-based zwitterionic interpenetrating polymer network (Alg-ZW IPN) that integrates a binary crosslinker system into the IPN architecture by pairing a short-chain crosslinker, N,N′-methylenebisacrylamide (MbAm), with a long-chain crosslinker, poly(ethylene glycol) dimethacrylate (PEGDMA). In the binary crosslinked IPN (Alg-ZW BIPN), MbAm establishes dense local junctions for structural integrity, while PEGDMA spans the interjunction domains to mechanically bridge the network, confine alginate chains, and stabilize Ca2+–alginate coordination. This architecture redistributes mechanical stress across length scales, thereby improving coating durability. The Alg-ZW BIPN coating exhibited ultralow friction, with a friction coefficient of 0.01–0.02, and maintained 49% lower friction than MbAm single crosslinker coatings. In catheter insertion tests using a standard vascular phantom, the coating reduced insertion force by up to 75% compared with uncoated catheters. The coating also inhibited Escherichia coli adhesion by 97.4% relative to uncoated substrates and showed excellent biocompatibility, with a hemolysis ratio of 0.17% and >95% endothelial cell viability after 24 h. Overall, the Alg-ZW BIPN design provides a general and scalable route to mechanically robust, lubricious, and antifouling hydrogel interfaces for indwelling medical devices.

  • Open Access

    Design of Extrusion Die for Medical Multi-lumen Tube Using Inverse Extrusion Simulation and Optimization

    by Yerim Kim, Kyungwook Ko, Wonjin Jun, Woojin Kim, Euntaek Lee

    The design of the extrusion die significantly affects both the extrusion process and the quality of multi-lumen tubes. Traditional design methods that rely on trial and error tend to increase manufacturing time and costs while diminishing product quality. This study utilizes inverse extrusion simulation and optimization to design the extrusion die without the need for trial and error. The inverse extrusion simulation generates the die profile necessary to achieve the desired extrudate shape. Subsequently, direct extrusion simulations are conducted to predict the extrudate profile based on the derived die. The optimal volumetric flow rates of air within the lumens are also identified to ensure the extrudate meets the target profile. The results from the direct extrusion simulation, combined with optimization, confirm that the designed extrusion die can successfully produce the target profile. Using the derived die, the multi-lumen tube with the desired specifications is successfully extruded. This design and manufacturing approach enhances both the quality and productivity of multi-lumen tubes.

  • Open Access

    Study on the Variation in Mechanical Performance of Medical Balloons depending on Polymer Tube Extrusion Process Variables

    by Jin Su Lee, Gyu Man Kim, Sungkwon Lee, Woojin Kim, Euntaek Lee

    Balloon catheters are a key technology in medical devices, essential for minimally invasive procedures. This study quantitatively analyzes how the orientation characteristics of polymer tubes, influenced by extrusion conditions, affect the mechanical properties and compliance of the final balloon—where compliance refers to the change in diameter under external pressure. Nylon 12 tubes, with a target outer diameter of 1.2 mm and an inner diameter of 1.0 mm, were extruded under six different orientation conditions by varying the screw flow rate and puller speed. The tubes were processed under identical forming conditions, allowing for a consistent evaluation of their mechanical properties. As orientation increased, elongation decreased while yield strength increased, and these trends continued in the balloon, significantly influencing compliance. To quantitatively measure orientation, we introduced the dimensionless Deborah number. We established a curve-fitted experimental model that links extrusion conditions, polymer tube properties, and balloon compliance. This model allows for the prediction of balloon performance based on extrusion-stage parameters, providing a practical framework for process optimization. Overall, this study offers an effective quantitative indicator for forecasting balloon catheter performance based on extrusion conditions and supports the systematic design of medical balloon products.

  • Open Access

    Design Optimization and Mechanical Performance Evaluation of a Modified Coronary IV-OCT Catheter Adapted for Intracranial Navigation: A Preclinical Study

    by Tahsin Nairuz, Young-Suk Hwang, Min-Yong Kwon, Jae Hyun Kim, Sae Min Kwon, Hyuck-Jun Yoon, Seung-Ho Hur, Joonho Chung, Woo-Jin Kim, Sang-Hyun An, et al.

    The application of intravascular optical coherence tomography (IV-OCT) in neurovascular interventions is constrained by the mechanical inadequacy of conventional catheters in navigating the complex intracranial vasculature. To address this, we modified a coronary IV-OCT catheter, enhancing its mechanical performance for neurovascular applications. The modified catheter featured a 300 mm over-the-microwire segment and a dual-structured shaft (distal 50 mm nonbraided, proximal 250 mm braided) to improve trackability and pushability. We compared the modified and conventional catheters using a benchtop model with a simulated vessel path and an in vivo swine model. Trackability and pushability were quantitatively measured using resistance (N) and advancement distance (mm) in the simulated path. In the animal model, indirect performance metrics included the catheter tension angle (CTA) and pass of catheter (POC) through the fourth curvature of the external carotid artery (ECA). The modified catheter demonstrated superior pushability (172.9 ± 1.96 mm vs. 127.9 ± 2.86 mm, p < 0.05) and increased resistance (1.47 ± 0.036 N vs. 0.69 ± 0.032 N, p < 0.05). In vivo analysis further showed a significantly greater CTA (115.8 ± 8.5° vs. 77.6 ± 10.3°, p < 0.05) and higher POC success rate (83.3% vs. 11.1%, p < 0.05). These results indicate that the modified coronary IV-OCT catheter offers enhanced mechanical performance, suggesting its potential for safe and effective use in neurovascular procedures.


  • Facile Fabrication of Multifunctional Hydrogel Nanoweb Coating Using Carboxymethyl Chitosan-Based Short Nanofibers for Blood-Contacting Medical Devices

    by Se Kye Park, Jae Hak Shin, Dong Uk Lee, Jae Hee Jung, Injoo Hwang, Seung Hwa Yoo, Han Chang Lee, Inyong Park, Woojin Kim, Dong Yun Lee, et al.

    Blood-contacting medical devices (BCDs) require antithrombotic, antibacterial, and low-friction surfaces. Incorporating a nanostructured surface with the functional hydrogel onto BCD surfaces can enhance the performances; however, their fabrication remains challenging. Here, we introduce a straightforward method to fabricate a multifunctional hydrogel-based nanostructure on BCD surfaces using O-carboxymethyl chitosan-based short nanofibers (CMC-SNFs). CMC-SNFs, fabricated via electrospinning and cutting processes, are easily sprayed and entangled onto the BCD surface. The deposited CMC-SNFs form a robust nanoweb layer via fusion at the contact area of the nanofiber interfaces. The superhydrophilic CMS-SNF nanoweb surface creates a water-bound layer that effectively prevents the nonspecific adhesion of bacteria and blood cells, thereby enhancing both antimicrobial and antithrombotic performances. Furthermore, the CMC-SNF nanoweb exhibits excellent lubricity and durability on the bovine aorta. The demonstration results of the CMC-SNF coating on catheters and sheaths provide evidence of its capability to apply multifunctional surfaces simply for diverse BCDs.


  • Formation of Balloon with Porous Structures in NaCl Vapor Assisted by Amphiphilic Polymer for Stent Delivery System

    by Han Chang Lee, Se Kye Park, Hyobin Kim, Dong Yun Choi, Gyu Man Kim, Woojin Kim

    Recently, bioabsorbable vascular stents (BVSs) are actively studied owing to their ability to dissolve within the human body. However, despite their advantages, BVSs often dislodge from the expandable balloon‐based delivery system when transported to the lesion site. In this study, a novel methodology aiming at increasing the retention force between the stent and the delivery system is presented. The breath‐figure method is adopted to form a porous structure and enhance adhesion. Additionally, numerical and experimental methods are used to evaluate the effect of surface tension between two immiscible fluids (polymeric solutions and droplets). To control the interfacial tension between the solution and droplets, an amphiphilic polymer and NaCl‐added vapor are used. By selecting the appropriate parameters, a sponge‐like structure is prepared on the stent delivery system. To verify its applicability, the two types of structures presented in this study are experimentally compared. These findings provide valuable guidelines for understanding the mechanism of breath‐figure patterns. Thus, the innovative methodology developed in this study demonstrates simplicity and scalability for large‐area production, making it potentially applicable to industrial technologies and offering new insights into biomedical engineering.

  • Improvement of catheter tip morphology by mold material used for tip‐forming process

    by Gye Jun Lee, Wonjin Jun, Han Chang Lee, Seong Wook Choi, Gyu Man Kim, Woojin Kim

    As interventional procedures using catheters have rapidly developed, accordingly, the incidence of polymeric embolization is also increasing, with the main cause being the flash generated during tip forming of the catheter. This study has performed to change the material of the mold used to form catheter tips to prevent flash, which is a cause of polymeric embolism. The tip‐forming performance and the flash generation according to the main parameters of the tip‐forming process were analyzed: power, heating, cooling time, and insertion pressure. In addition, we observed the effect of flash suppression according to temperature sensitivity by changing the mold material considering thermal conductivity and electrical resistivity. In particular, considering the glass transition temperature of HDPE (high‐density polyethylene), which is applied to sheath and dilator catheters, the most stable tip forming proceeds when the temperature near the tip inside the mold was about 130°C. We verified experimentally and numerically that the temperature of the pins comprising the mold plays an important role in flash generation and confirmed that the viscosity of the polymer melts is lower at 120°C than at 90°C of the pin, and flash is minimized because of the shear‐thinning behavior of the polymer melts.


  • The Improvement of Roundness and Surface of Sheath & Dilator Catheter Tube

    by Gyu Ik Lee, Howon Lee, Gyu Man Kim, Woojin Kim, Euntaek Lee

    As the market for minimally invasive procedures developed rapidly, there was an increase in the demand for high-precision, high-performance catheter fabrication technology. Sheath and dilator tubes are essential intervention devices for procedures, in which catheters are used and require precise dimensional accuracy, and uniform roundness and surface roughness. Polyethylene is used in sheath and dilator limitation for processability, which causes low melt flow index and side effects. Therefore, in the extrusion process using polyethylene, it is important to study the manufacturing of tubes with improved roundness and surface roughness. In this study, we proposed a calibrator for precise production with an aim to manufacture 5Fr micro-puncture tubes, and studied the changes in the roundness and surface roughness of tubes by changing the cooling water temperature and water disk thickness. As a result, it was found that the cooling water temperature and wafer disk thickness had an effect on the roundness and surface roughness, and the roundness had an effect on the formation of the wall thickness. Therefore, these experimental results were used as a study for the production of improved Sheath and Dilator tubes.

  • Open Access

    Degradation Feature Extraction Method for Prognostics of an Extruder Screw Using Multi-Source Monitoring Data

    by Jun-Kyu Park, Howon Lee, Woojin Kim, Gyu-Man Kim, Dawn An

    Laboratory-scale data on a component level are frequently used for prognostics because acquiring them is time and cost efficient. However, they do not reflect actual field conditions. As prognostics is for an in-service system, the developed prognostic methods must be validated using real operational data obtained from an actual system. Because obtaining real operational data is much more expensive than obtaining test-level data, studies employing field data are scarce. In this study, a prognostic method for screws was presented by employing multi-source real operational data obtained from a micro-extrusion system. The analysis of real operational data is more challenging than that of test-level data because the mutual effect of each component in the system is chaotically reflected in the former. This paper presents a degradation feature extraction method for interpreting complex signals for a real extrusion system based on the physical and mechanical properties of the system as well as operational data. The data were analyzed based on general physical properties and the inferred interpretation was verified using the data. The extracted feature exhibits valid degradation behavior and is used to predict the remaining useful life of the screw in a real extrusion system.


  • Study on Improvement of Catheter Tip Forming Process according to Plating Characteristics in Mold

    by Han Chang Lee, Jinhyuk Jung, Gyu Ik Lee, Woojin Kim, Gyu Man Kim, Bong Gu Lee

    Catheter tip forming is processing the tip at the distal end so that catheter can move smoothly through the geometrically complex vascular structure. This thermoforming process has a problem in that the polymer tube adheres to the outer surface of the mold. To resolve this problem, previous researchers have coated the outer surface of the mold with PTFE (Polytetrafluoroethylene), which has a low coefficient of friction. However, due to repeated use, the coating is detached and the polymer tube adheres to the mandrels again, and the mold is frequently replaced. Thus, in this study, three types of metal were electroplated on the surface of the mold in to realize the performance of the PTFE coating. To select the optimal plating material, Cr, Zn, and Ni were selected as candidate groups. Surface energy, adhesion force, and abrasion depth & volume were measured for performance comparison. As a result, Ni, which has similar surface properties to PTFE, and the best durability, was selected as the optimal material. Based on these results, we present Ni-plated mold that can replace PTFE.