Implementation of Decoupling Power Flow Control System in Triple Active Bridge Converter Rated at 400V, 10kW, and 20kHz
Authors:
- 1 September 2018
- journal article
- research article
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Journal of Industry Applications
- Vol. 7 (5) , 410-415
Abstract
An autonomous DC microgrid system that uses a triple active bridge (TAB) converter as a power routing unit is proposed. A control system that can independently manage the current and voltage of each port is needed to construct the microgrid. This paper describes how the decoupling power flow control system is implemented in the prototype TAB converter rated at 400V, 10kW, and 20kHz. The validity of the system was demonstrated by measuring the step response of the TAB converter. The experimental results showed that the system provided the designed dynamic characteristics from the viewpoints of output current control and constant voltage control. Decoupling power flow control between each port was also achieved.Keywords
This publication has 17 references indexed in Scilit:
- Multiport power router and its impact on future smart gridsRadio Science, 2016
- Optimal power flow for AC-DC networks2014
- Voltage Control Scheme with Distributed Generation and Grid Connected Converter in a DC MicrogridEnergies, 2014
- A Transformerless Back-To-Back (BTB) System Using Modular Multilevel Cascade Converters For Power Distribution SystemsIEEE Transactions on Power Electronics, 2014
- Overview of Dual-Active-Bridge Isolated Bidirectional DC–DC Converter for High-Frequency-Link Power-Conversion SystemIEEE Transactions on Power Electronics, 2013
- The Future Renewable Electric Energy Delivery and Management (FREEDM) System: The Energy InternetProceedings of the IEEE, 2010
- Full-order averaging modelling of zero-voltage-switching phase-shift bidirectional DC–DC convertersIET Power Electronics, 2010
- An Isolated Three-Port Bidirectional DC-DC Converter With Decoupled Power Flow ManagementIEEE Transactions on Power Electronics, 2008
- A Bi-Directional Isolated DC/DC Converter as a Core Circuit for 3.3-kV/6.6-kV Power Conversion Systems in the Next GenerationIEEJ Transactions on Industry Applications, 2006
- Generalized averaging method for power conversion circuitsIEEE Transactions on Power Electronics, 1991