Yuichi Kado
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yuichi Kado has a total of 245 co-authors. Here are the top co-authors by number of shared publications:
Naoya Kukutsu
NTT Microsystem Integration Laboratories, NTT Corporation, Atsugi-shi, Kanagawa, Japan
24 shared publicationsMitsuru Shinagawa
19 shared publicationsTadao Nagatsuma
Osaka University
18 shared publicationsAkihiko Hirata
NTT Microsystem Integration Laboratories, NTT Corporation, Atsugi-shi, Kanagawa, Japan
15 shared publicationsToshihiko Kosugi
NTT Photonics Laboratories, NTT Corporation, Atsugi-shi, Kanagawa, Japan
13 shared publicationsHiroyuki Takahashi
NTT Microsystem Integration Laboratories, NTT Corporation, Atsugi-shi, Kanagawa, Japan
12 shared publications
Latest Publications
- Open Access
- 9 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 4, 34-51
Multilevel Switched Capacitor LLC-DCX Converter With Embedded Filter
A multilevel switched capacitor LLC-DC transformer (LLC-DCX) converter with an embedded filter is presented for a power module of solid-state transformers. The proposed converter is a hybrid converter composed of resonant switched capacitor converters (RSCCs) and a previously reported ripple-cancel converter. In contrast to the conventional SCC, which faces the issue of an inrush hard-charging current during switching transition, the proposed converter can be implemented using a soft-charging operation without additional inductors. Further, it inherits the advantages of the two converters, including load-independent soft switching, automatic voltage sharing, automatic current sharing, reduction of the current ripple, an embedded filter function, constant voltage gain, and flexible extensibility. This paper comprehensively analyzes these characteristics and the conditions for soft-charging operation. The design theory based on the analysis is also presented. We fabricated a prototype of the proposed converter with input and output voltages of 900 V and 150 V, respectively and the rated output power of 2 kW to demonstrate the validity of the analysis and design.
- 9 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 4, 34-51
Open AccessMultilevel Switched Capacitor LLC-DCX Converter With Embedded Filter
A multilevel switched capacitor LLC-DC transformer (LLC-DCX) converter with an embedded filter is presented for a power module of solid-state transformers. The proposed converter is a hybrid converter composed of resonant switched capacitor converters (RSCCs) and a previously reported ripple-cancel converter. In contrast to the conventional SCC, which faces the issue of an inrush hard-charging current during switching transition, the proposed converter can be implemented using a soft-charging operation without additional inductors. Further, it inherits the advantages of the two converters, including load-independent soft switching, automatic voltage sharing, automatic current sharing, reduction of the current ripple, an embedded filter function, constant voltage gain, and flexible extensibility. This paper comprehensively analyzes these characteristics and the conditions for soft-charging operation. The design theory based on the analysis is also presented. We fabricated a prototype of the proposed converter with input and output voltages of 900 V and 150 V, respectively and the rated output power of 2 kW to demonstrate the validity of the analysis and design.
- Open Access
- 11 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 7716-7733
Analysis and Comparison of Series Resonant Converter With Embedded Filters for High Power Density DCX of Solid-State Transformer
A series resonant converter (SRC) operating as a DC transformer (DCX) is a candidate for the isolated bidirectional DC/DC converters of solid-state transformers (SSTs). However, the input/output current ripple of the SRC is relatively high, which requires bulky parallel capacitors and low-pass filters such as C/LC filters. These additional components reduce the power density. In addition, to operate an SRC as a DCX, a small resonant inductance is desired to reduce the voltage gain variation and achieve a faster transient response. To resolve these problems, a SRC with embedded filters is studied. Adding a clamping capacitor between split transformers not only significantly reduces current ripples and the harmonic components of the input/output currents but also connects resonant inductors in parallel to reduce the equivalent resonant inductance. In addition, dividing the resonant current into two split windings reduces the RMS current of the transformer. This paper presents a detailed analysis, a design methodology, and a comprehensive comparison with the conventional half-bridge CLLC converter with C/LC filters. 1-kW prototypes with a 600-V input voltage and 200-V output voltage demonstrate the superiority of the proposed converter; the second harmonic of the output current was significantly suppressed by 19.3 dB compared with that of the conventional converter with the same power density. The loss breakdown showed the proposed converter mitigated copper loss by 9.47% and eliminated the losses of the filter and DC-link capacitors. The prototype of the proposed converter had the highest efficiency of 95.4% at full-load among prototypes.
- 11 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 7716-7733
Open AccessAnalysis and Comparison of Series Resonant Converter With Embedded Filters for High Power Density DCX of Solid-State Transformer
A series resonant converter (SRC) operating as a DC transformer (DCX) is a candidate for the isolated bidirectional DC/DC converters of solid-state transformers (SSTs). However, the input/output current ripple of the SRC is relatively high, which requires bulky parallel capacitors and low-pass filters such as C/LC filters. These additional components reduce the power density. In addition, to operate an SRC as a DCX, a small resonant inductance is desired to reduce the voltage gain variation and achieve a faster transient response. To resolve these problems, a SRC with embedded filters is studied. Adding a clamping capacitor between split transformers not only significantly reduces current ripples and the harmonic components of the input/output currents but also connects resonant inductors in parallel to reduce the equivalent resonant inductance. In addition, dividing the resonant current into two split windings reduces the RMS current of the transformer. This paper presents a detailed analysis, a design methodology, and a comprehensive comparison with the conventional half-bridge CLLC converter with C/LC filters. 1-kW prototypes with a 600-V input voltage and 200-V output voltage demonstrate the superiority of the proposed converter; the second harmonic of the output current was significantly suppressed by 19.3 dB compared with that of the conventional converter with the same power density. The loss breakdown showed the proposed converter mitigated copper loss by 9.47% and eliminated the losses of the filter and DC-link capacitors. The prototype of the proposed converter had the highest efficiency of 95.4% at full-load among prototypes.
- 1 September 2018
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Journal of Industry Applications
- Vol. 7 (5) , 410-415
Implementation of Decoupling Power Flow Control System in Triple Active Bridge Converter Rated at 400V, 10kW, and 20kHz
An autonomous DC microgrid system that uses a triple active bridge (TAB) converter as a power routing unit is proposed. A control system that can independently manage the current and voltage of each port is needed to construct the microgrid. This paper describes how the decoupling power flow control system is implemented in the prototype TAB converter rated at 400V, 10kW, and 20kHz. The validity of the system was demonstrated by measuring the step response of the TAB converter. The experimental results showed that the system provided the designed dynamic characteristics from the viewpoints of output current control and constant voltage control. Decoupling power flow control between each port was also achieved.
- 1 September 2018
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Journal of Industry Applications
- Vol. 7 (5) , 410-415
Implementation of Decoupling Power Flow Control System in Triple Active Bridge Converter Rated at 400V, 10kW, and 20kHz
An autonomous DC microgrid system that uses a triple active bridge (TAB) converter as a power routing unit is proposed. A control system that can independently manage the current and voltage of each port is needed to construct the microgrid. This paper describes how the decoupling power flow control system is implemented in the prototype TAB converter rated at 400V, 10kW, and 20kHz. The validity of the system was demonstrated by measuring the step response of the TAB converter. The experimental results showed that the system provided the designed dynamic characteristics from the viewpoints of output current control and constant voltage control. Decoupling power flow control between each port was also achieved.
- Open Access
- 1 August 2017
- Published by ASTES Journal in Advances in Science, Technology and Engineering Systems Journal
- Vol. 2 (3) , 1350-1357
Compact wireless control network protocol with fast path switching
- 1 August 2017
- Published by ASTES Journal in Advances in Science, Technology and Engineering Systems Journal
- Vol. 2 (3) , 1350-1357
Open AccessCompact wireless control network protocol with fast path switching
- 1 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 182-184
Azimuth characteristics of radio wave propagation in a mulberry farm in 920-MHz band
Data collection of the radio wave propagation loss in farm fields is valuable to design a wireless network in a farm. They are used in calculating the link budget to establish a proper and efficient node arrangement. In this study, propagation losses in a 50 × 50 m mulberry field were measured in 920-MHz band with respect to the azimuthal angle of the propagation direction to arrays of bushes. Received signal strength indicators (RSSIs) were measured and they were converted to the path loss. Antennas were placed at a height of 1.5 m while the height of the bush was 3.5 m. Moreover, horizontal and vertical polarizations were measured. The results revealed that the horizontal polarization could be less affected by the direction angle to the ridges than the vertical polarization. These data would be useful for the evaluation of link budgets to design wireless networks in a farm.
- 1 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 182-184
Azimuth characteristics of radio wave propagation in a mulberry farm in 920-MHz band
Data collection of the radio wave propagation loss in farm fields is valuable to design a wireless network in a farm. They are used in calculating the link budget to establish a proper and efficient node arrangement. In this study, propagation losses in a 50 × 50 m mulberry field were measured in 920-MHz band with respect to the azimuthal angle of the propagation direction to arrays of bushes. Received signal strength indicators (RSSIs) were measured and they were converted to the path loss. Antennas were placed at a height of 1.5 m while the height of the bush was 3.5 m. Moreover, horizontal and vertical polarizations were measured. The results revealed that the horizontal polarization could be less affected by the direction angle to the ridges than the vertical polarization. These data would be useful for the evaluation of link budgets to design wireless networks in a farm.
- 9 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2551-2554
Interference problem of fixed transmitter during intra-body communication
This paper describes the interference problem of a fixed transmitter driven by an alternating current (AC) power source during intra-body communication. The fixed transmitter is strongly electrically coupled with the ground through the AC power source. We believe that the interference signal of a fixed transmitter is larger than that of a wearable transmitter driven by a battery. We investigated the interference problem of a fixed transmitter through an electromagnetic field simulation. The interference signal of the fixed transmitter was larger than that of the wearable transmitter, but the correct-to-interference ratio of the fixed transmitter was almost equal to that of the wearable transmitter with the same simulation model. The correct-to-interference ratio was improved by reducing the electrode size of the fixed transmitter. It was confirmed that the Cu wall located between two people is effective in preventing interference.
- 9 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2551-2554
Interference problem of fixed transmitter during intra-body communication
This paper describes the interference problem of a fixed transmitter driven by an alternating current (AC) power source during intra-body communication. The fixed transmitter is strongly electrically coupled with the ground through the AC power source. We believe that the interference signal of a fixed transmitter is larger than that of a wearable transmitter driven by a battery. We investigated the interference problem of a fixed transmitter through an electromagnetic field simulation. The interference signal of the fixed transmitter was larger than that of the wearable transmitter, but the correct-to-interference ratio of the fixed transmitter was almost equal to that of the wearable transmitter with the same simulation model. The correct-to-interference ratio was improved by reducing the electrode size of the fixed transmitter. It was confirmed that the Cu wall located between two people is effective in preventing interference.
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3 (21654743) , 1-4
Effect of vegetation on radio wave propagation in 920-MHz and 2.4-GHz bands
Collecting data of propagation losses in farm fields is important to design a wireless network in a farm. They are used in calculating the link budget to establish a proper and efficient node arrangement. In this study, propagation losses in a 50 × 50 m mulberry field were measured in 920-MHz and 2.4-GHz bands. Received signal strength indicators (RSSIs) were measured as a function of the distance and the angle between the propagation direction and the ridges (bush arrays). The data were converted to the vegetation attenuations and the propagation characteristics were compared in both bands. The antennas were placed at a height of 1.5 m. The height of the bush was 1.5 - 3.5 m. Moreover, the horizontal and vertical polarizations were measured and the differences were shown.
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3 (21654743) , 1-4
Effect of vegetation on radio wave propagation in 920-MHz and 2.4-GHz bands
Collecting data of propagation losses in farm fields is important to design a wireless network in a farm. They are used in calculating the link budget to establish a proper and efficient node arrangement. In this study, propagation losses in a 50 × 50 m mulberry field were measured in 920-MHz and 2.4-GHz bands. Received signal strength indicators (RSSIs) were measured as a function of the distance and the angle between the propagation direction and the ridges (bush arrays). The data were converted to the vegetation attenuations and the propagation characteristics were compared in both bands. The antennas were placed at a height of 1.5 m. The height of the bush was 1.5 - 3.5 m. Moreover, the horizontal and vertical polarizations were measured and the differences were shown.
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
NES-SOURCE: Indoor small-scale wireless control network protocol that has a communication failure point avoidance function
Wireless control network require delay guarantees and low packet error rates. The reason for communication delay and error is packet loss, and TDMA is used by many wireless control network technologies to avoid packet loss. However, TDMA protocols are difficult to implement. Besides, TDMA cannot avoid communication failure points due to changes in the environment caused by human intervention. We propose NES-SOURCE as a CSMA/CA based control network protocol. NES-SOURCE uses a source routing protocol, and if the NES-SOURCE node fails to communicate using primary route, the node avoid the communication failure point by to use secondary bypass route. NES-SOURCE is a low delay protocol. The reason is that NES-SOURCE can change the communication route at high speed. In addition, NES-SOUCE is implemented using a protocol stack that is compatible with IEEE 802.15.4 g. We show that NES-SOURCE systems can be used for wireless control network systems, and in an environment where people moving are in and out, path change is more advantageous than retransmission from the point of view of the packet error rate.
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
NES-SOURCE: Indoor small-scale wireless control network protocol that has a communication failure point avoidance function
Wireless control network require delay guarantees and low packet error rates. The reason for communication delay and error is packet loss, and TDMA is used by many wireless control network technologies to avoid packet loss. However, TDMA protocols are difficult to implement. Besides, TDMA cannot avoid communication failure points due to changes in the environment caused by human intervention. We propose NES-SOURCE as a CSMA/CA based control network protocol. NES-SOURCE uses a source routing protocol, and if the NES-SOURCE node fails to communicate using primary route, the node avoid the communication failure point by to use secondary bypass route. NES-SOURCE is a low delay protocol. The reason is that NES-SOURCE can change the communication route at high speed. In addition, NES-SOUCE is implemented using a protocol stack that is compatible with IEEE 802.15.4 g. We show that NES-SOURCE systems can be used for wireless control network systems, and in an environment where people moving are in and out, path change is more advantageous than retransmission from the point of view of the packet error rate.
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 793-796
Implementation and power-loss characteristics of 400-V, 10-kW, 20-kHz three-way isolated DC/DC converter as a power routing unit for constructing microgrid systems
We propose an autonomous DC microgrid system in which a three-way isolated DC/DC converter is used as a power routing unit for constructing DC 400 V microgrid systems. As the unit in the system operates with various power flow patterns, a highly efficient system cannot easily be designed unless the dependence of the unit's overall loss on the flow pattern is suppressed and efficiency variations in all operational states are small. We made a prototype three-way isolated DC/DC converter consisting of SiC-MOSFETs rated at 400 V, 20 kHz, and 10 kW and demonstrated power distribution operation. We present the dependence of overall loss in the three-way converter as revealed by results of experiments and analyze the factors involved in this dependence.
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 793-796
Implementation and power-loss characteristics of 400-V, 10-kW, 20-kHz three-way isolated DC/DC converter as a power routing unit for constructing microgrid systems
We propose an autonomous DC microgrid system in which a three-way isolated DC/DC converter is used as a power routing unit for constructing DC 400 V microgrid systems. As the unit in the system operates with various power flow patterns, a highly efficient system cannot easily be designed unless the dependence of the unit's overall loss on the flow pattern is suppressed and efficiency variations in all operational states are small. We made a prototype three-way isolated DC/DC converter consisting of SiC-MOSFETs rated at 400 V, 20 kHz, and 10 kW and demonstrated power distribution operation. We present the dependence of overall loss in the three-way converter as revealed by results of experiments and analyze the factors involved in this dependence.