A Novel Battery-Supplied AFE EEG Circuit Capable of Muscle Movement Artifact Suppression
Preprint
- 1 May 2024
- preprint
- Published by MDPI AG in Preprints.org
Abstract
In this study, the fundamentals of electroencephalography signals, their categorization into frequency sub-bands, the circuitry used for their acquisition, and the impact of noise interference on signal acquisition are examined. Additionally, design specifications for medical-grade and research-grade EEG circuits and a comprehensive analysis of various analog front-end architectures for electroencephalograph (EEG) circuit design are presented. Three distinct selected case studies are examined in terms of comparative evaluation with generic EEG circuit design templates. Moreover, a novel one-channel battery-supplied EEG analog front-end circuit designed to address the requirements of usage protocols containing strong com-pound muscle movements is introduced. Furthermore, a realistic input signal generator circuit is proposed that models the human body and the Electromagnetic Interference from its surroundings. Experimental simulations are conducted in 50 Hz and 60 Hz electrical grid environments to evaluate the performance of the novel design. The results demonstrate the efficacy of the proposed system, particularly in terms of bandwidth, portability, common mode rejection ratio , gain, suppression of muscle movement artifacts, electrostatic discharge and leakage current protection. Conclusively, the novel design is cost-effective and suitable for both commercial and research single-channel EEG applications. It can be easily incorporated in Brain Computer Interfaces and neurofeedback training systems.Keywords
All Related Versions
This publication has 31 references indexed in Scilit:
- Brain-Related Diseases and Role of Electroencephalography (EEG) in Diagnosing Brain Disorders2020
- A systematic review of EEG source localization techniques and their applications on diagnosis of brain abnormalitiesJournal of Neuroscience Methods, 2020
- Electroencephalographic monitoring in the critically ill patient: What useful information can it contribute?Medicina Intensiva (English Edition), 2020
- Standards of instrumentation of EMGClinical Neurophysiology, 2020
- Where Does EEG Come From and What Does It Mean?Trends in Neurosciences, 2017
- Electroencephalogram (EEG) and Its Background2016
- Classification of electroencephalogram signals with combined time and frequency featuresExpert Systems with Applications, 2011
- Analog Filters2008
- Fundamentals of EEG Signal Processing2007
- Full-band EEG (FbEEG): an emerging standard in electroencephalographyClinical Neurophysiology, 2005