Multiparametric Characterisation of a Recursive Filtration Algorithm on a Commercial Angiographic Equipment
Authors:
- 7 July 2026
- journal article
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
Abstract
Digital fluoroscopy offers high temporal resolution but is limited by substantial noise. Recursive filtration improves the signal-to-noise ratio (SNR) by combining information across frames, though potentially at the cost of motion blur and contrast loss. This study evaluates recursive filtering performance in a commercial angiographic system, specifically where filter parameters (e.g. K-factor) are not explicitly disclosed. Fluoroscopic images were acquired using a rotating phantom with high- and low-contrast objects. Image quality was assessed using noise power spectrum (NPS), contrast-to-noise ratio (CNR), and lag analysis. Manual K-factor settings were compared with automatic configurations, and a model was developed to estimate the effective K-factor based on NPS characteristics. Higher K-factors yielded substantial noise reduction but increased lag and decreased contrast. Automatic filtering modes provided a more balanced outcome, achieving noise suppression comparable to high K-factor values while preserving contrast and minimising motion artefacts. Estimated K-factors from automatic modes varied with temporal frequency, reflecting adaptive filter behaviour. Understanding the effects of undisclosed filter settings is critical for protocol optimisation. These findings support adaptive filtering strategies tailored to clinical tasks, enhancing imaging performance and patient safety.Keywords
This publication has 11 references indexed in Scilit:
- Unsupervised Training of a Dynamic Context-Aware Deep Denoising Framework for Low-Dose Fluoroscopic ImagingIEEE Transactions on Instrumentation and Measurement, 2025
- Performance evaluation of two interventional fluoroscope suites for cardiovascular imagingJournal of Applied Clinical Medical Physics, 2022
- Adaptive spatio-temporal denoising of fluoroscopic X-ray sequencesBiomedical Signal Processing and Control, 2012
- Mathematical functions for the analysis of luminescence decays with underlying distributions 1. Kohlrausch decay function (stretched exponential)Chemical Physics, 2005
- Quantitative fluoroscopic dose saving in cardiovascular imaging with a novel motion discriminating temporal filter2005
- Characterization of continuously distributed cortical water diffusion rates with a stretched‐exponential modelMagnetic Resonance in Medicine, 2003
- A framework for noise‐power spectrum analysis of multidimensional imagesMedical Physics, 2002
- Fluoroscopy: Patient Radiation Exposure IssuesRadioGraphics, 2001
- A method for time domain filtering using computerized fluoroscopyMedical Physics, 1981
- Non-symmetrical dielectric relaxation behaviour arising from a simple empirical decay functionTransactions of the Faraday Society, 1970