Raffaele Villa
Research Subjects
Raffaele Villa has a total of 131 co-authors. Here are the top co-authors by number of shared publications:
- Nicoletta Paruccini
Medical Physics Department, ASST Monza, Italy
4 shared publications Daniela Origgi
IEO European Institute of Oncology IRCCS, Milano, Italy
2 shared publicationsElena De Ponti
Medical Physics Department, Fondazione IRCCS San Gerardo Dei Tintori, Monza, Italy
2 shared publicationsFelicita Luraschi
Azienda Socio Sanitaria Territoriale di Cremona, Cremona, Cremona, 26100, ITALY
2 shared publicationsFrancesca Pietrobon
Azienda ULSS n 1 Dolomiti Distretto 1 Belluno, viale Europa, 22, Belluno, Veneto, 32100, ITALY
2 shared publications- Mariagrazia Quattrocchi
Medical Physics Structure, Azienda Toscana Nord Ovest, Lucca, Italy
2 shared publications
Latest Publications
- Open Access
- 6 October 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (10) , e70838
Assessment of image quality and detectability in computed tomography: Inter‐laboratory comparison of Fourier‐based metrics
Background: The task‐based assessment of image quality in computed tomography (CT) is increasingly used for benchmarking, optimizing acquisition and reconstruction parameters, and predicting observers’ performance. To achieve consistent and reproducible results rely on standardized methodologies and guidelines. Purpose: This study performed an inter‐laboratory comparison to evaluate the consistency of CT image quality metrics and assess inter‐laboratory variability. Methods: Six series of images of a Catphan 500 phantom were acquired at three dose levels (1.5/5.0/15.0 mGy) with two (standard and high‐resolution) kernels and sent to seven independent laboratories. Participants calculated the task transfer function (TTF) for spatial resolution and noise power spectrum (NPS) for noise magnitude and texture using standardized Fourier‐based analysis on the shared images. The TTFs and NPS were used in the non‐prewhitening observer model without (NPW) and with eye filter (NPWE) to calculate a detectability index for small (2 mm) and large targets (10 mm). Results: The difference observed in TTFs resulted mainly from the different noise reduction techniques used during the calculation. The frequency corresponding to the TTF value 50% varied from 0.27 to 0.43 mm −1 for the standard images and from 0.73 to 0.92 mm −1 for the high‐resolution images. Variability in NPS primarily stemmed from the choice of regions of interest location in non‐stationary noise images that lead to magnitude differences up to 40% for the standard kernel and 70% for the high‐resolution kernel. The combined differences in TTF and NPS resulted in differences up to 39% in the NPW detectability index. The large variability in the human visual transfer function and visualization parameters increased the differences by a factor of 6.25 in the NPWE model and highlighted the lack of standardization. Conclusion: Adapting TTF and NPS to a more complex and localized analysis of CT images with non‐uniform CNRs, rather than a simple global evaluation, increases computational variability and requires a move towards more standardization of metrics. In the absence of complete standardization of image quality measurement, documentation of methods and all calculation parameters is essential for more robust evaluation of CT image quality.
- 6 October 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (10) , e70838
Open AccessAssessment of image quality and detectability in computed tomography: Inter‐laboratory comparison of Fourier‐based metrics
Background: The task‐based assessment of image quality in computed tomography (CT) is increasingly used for benchmarking, optimizing acquisition and reconstruction parameters, and predicting observers’ performance. To achieve consistent and reproducible results rely on standardized methodologies and guidelines. Purpose: This study performed an inter‐laboratory comparison to evaluate the consistency of CT image quality metrics and assess inter‐laboratory variability. Methods: Six series of images of a Catphan 500 phantom were acquired at three dose levels (1.5/5.0/15.0 mGy) with two (standard and high‐resolution) kernels and sent to seven independent laboratories. Participants calculated the task transfer function (TTF) for spatial resolution and noise power spectrum (NPS) for noise magnitude and texture using standardized Fourier‐based analysis on the shared images. The TTFs and NPS were used in the non‐prewhitening observer model without (NPW) and with eye filter (NPWE) to calculate a detectability index for small (2 mm) and large targets (10 mm). Results: The difference observed in TTFs resulted mainly from the different noise reduction techniques used during the calculation. The frequency corresponding to the TTF value 50% varied from 0.27 to 0.43 mm −1 for the standard images and from 0.73 to 0.92 mm −1 for the high‐resolution images. Variability in NPS primarily stemmed from the choice of regions of interest location in non‐stationary noise images that lead to magnitude differences up to 40% for the standard kernel and 70% for the high‐resolution kernel. The combined differences in TTF and NPS resulted in differences up to 39% in the NPW detectability index. The large variability in the human visual transfer function and visualization parameters increased the differences by a factor of 6.25 in the NPWE model and highlighted the lack of standardization. Conclusion: Adapting TTF and NPS to a more complex and localized analysis of CT images with non‐uniform CNRs, rather than a simple global evaluation, increases computational variability and requires a move towards more standardization of metrics. In the absence of complete standardization of image quality measurement, documentation of methods and all calculation parameters is essential for more robust evaluation of CT image quality.
- 7 July 2026
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
Multiparametric Characterisation of a Recursive Filtration Algorithm on a Commercial Angiographic Equipment
Digital fluoroscopy offers high temporal resolution but is limited by substantial noise. Recursive filtration improves the signal-to-noise ratio (SNR) by combining information across frames, though potentially at the cost of motion blur and contrast loss. This study evaluates recursive filtering performance in a commercial angiographic system, specifically where filter parameters (e.g. K-factor) are not explicitly disclosed. Fluoroscopic images were acquired using a rotating phantom with high- and low-contrast objects. Image quality was assessed using noise power spectrum (NPS), contrast-to-noise ratio (CNR), and lag analysis. Manual K-factor settings were compared with automatic configurations, and a model was developed to estimate the effective K-factor based on NPS characteristics. Higher K-factors yielded substantial noise reduction but increased lag and decreased contrast. Automatic filtering modes provided a more balanced outcome, achieving noise suppression comparable to high K-factor values while preserving contrast and minimising motion artefacts. Estimated K-factors from automatic modes varied with temporal frequency, reflecting adaptive filter behaviour. Understanding the effects of undisclosed filter settings is critical for protocol optimisation. These findings support adaptive filtering strategies tailored to clinical tasks, enhancing imaging performance and patient safety.
- 7 July 2026
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
Multiparametric Characterisation of a Recursive Filtration Algorithm on a Commercial Angiographic Equipment
Digital fluoroscopy offers high temporal resolution but is limited by substantial noise. Recursive filtration improves the signal-to-noise ratio (SNR) by combining information across frames, though potentially at the cost of motion blur and contrast loss. This study evaluates recursive filtering performance in a commercial angiographic system, specifically where filter parameters (e.g. K-factor) are not explicitly disclosed. Fluoroscopic images were acquired using a rotating phantom with high- and low-contrast objects. Image quality was assessed using noise power spectrum (NPS), contrast-to-noise ratio (CNR), and lag analysis. Manual K-factor settings were compared with automatic configurations, and a model was developed to estimate the effective K-factor based on NPS characteristics. Higher K-factors yielded substantial noise reduction but increased lag and decreased contrast. Automatic filtering modes provided a more balanced outcome, achieving noise suppression comparable to high K-factor values while preserving contrast and minimising motion artefacts. Estimated K-factors from automatic modes varied with temporal frequency, reflecting adaptive filter behaviour. Understanding the effects of undisclosed filter settings is critical for protocol optimisation. These findings support adaptive filtering strategies tailored to clinical tasks, enhancing imaging performance and patient safety.
- Open Access
- 23 September 2025
- Published by Elsevier in Physica Medica
- Vol. 138, 105171
A multicentre study to compare previous and new breast dosimetry for Digital Mammography, Digital Breast Tomosynthesis and Contrast Enhanced Mammography
- 23 September 2025
- Published by Elsevier in Physica Medica
- Vol. 138, 105171
Open AccessA multicentre study to compare previous and new breast dosimetry for Digital Mammography, Digital Breast Tomosynthesis and Contrast Enhanced Mammography
- Open Access
- 4 July 2025
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (4) , 045020
Implementation and validation of a channelized hotelling observer model (CHO) in an AIFM task group: a national multicentric study in x-ray angiography (XA), a comprehensive and wide-reaching approach
This study aims to prove the feasibility of objectively characterizing clinical XA protocols by implementing a model observer. The model observer’s performance aligns with a human observer’s and is described using a simple and comprehensive figure of merit (FOM). The practical implications of this study, which utilized the Leeds TO10 phantom to acquire 146 imaging datasets in a fixed setup measuring kerma rate from four manufacturers and seven XA models by thirteen hospitals, are significant. The datasets were divided and analyzed into three main protocol categories (cardiac, neurological, and vascular) acquired with the field of view (FOV) locally used in that hospital. A 40-channel Gabor CHO was employed to analyze the datasets and calculate the contrast detail (CD) curves. A new figure of merit (FOM) tailored for the present task was calculated, accounting for image quality and kerma rate. The FOM demonstrated our observer model’s ability to describe the XA protocol’s optimization. Short-term reproducibility of selected XA protocols was within 10%. Smaller FOVs lowered long-term reproducibility in terms of FOM because the position of the dosimeter increasingly influenced the automatic exposure parameters. This study demonstrates the feasibility of using a CHO model observer to assess an angiography system’s quality using a CD paradigm. The insights gained from this study will be instrumental in developing tolerance requirements for future quality assurance guides, enhancing the quality of X-ray angiography protocols, and improving patient care.
- 4 July 2025
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (4) , 045020
Open AccessImplementation and validation of a channelized hotelling observer model (CHO) in an AIFM task group: a national multicentric study in x-ray angiography (XA), a comprehensive and wide-reaching approach
This study aims to prove the feasibility of objectively characterizing clinical XA protocols by implementing a model observer. The model observer’s performance aligns with a human observer’s and is described using a simple and comprehensive figure of merit (FOM). The practical implications of this study, which utilized the Leeds TO10 phantom to acquire 146 imaging datasets in a fixed setup measuring kerma rate from four manufacturers and seven XA models by thirteen hospitals, are significant. The datasets were divided and analyzed into three main protocol categories (cardiac, neurological, and vascular) acquired with the field of view (FOV) locally used in that hospital. A 40-channel Gabor CHO was employed to analyze the datasets and calculate the contrast detail (CD) curves. A new figure of merit (FOM) tailored for the present task was calculated, accounting for image quality and kerma rate. The FOM demonstrated our observer model’s ability to describe the XA protocol’s optimization. Short-term reproducibility of selected XA protocols was within 10%. Smaller FOVs lowered long-term reproducibility in terms of FOM because the position of the dosimeter increasingly influenced the automatic exposure parameters. This study demonstrates the feasibility of using a CHO model observer to assess an angiography system’s quality using a CD paradigm. The insights gained from this study will be instrumental in developing tolerance requirements for future quality assurance guides, enhancing the quality of X-ray angiography protocols, and improving patient care.
- Open Access
- 1 October 2024
- Published by Elsevier in Physica Medica
- Vol. 126, 104831
In vivo dosimetry of total body irradiation patients: A 10 year retrospective analysis
- 1 October 2024
- Published by Elsevier in Physica Medica
- Vol. 126, 104831
Open AccessIn vivo dosimetry of total body irradiation patients: A 10 year retrospective analysis
- Open Access
- 9 March 2023
- Published by Elsevier in Physica Medica
- Vol. 108, 102556
Spatio-temporal generalized Model Observers methods for Low Contrast Detectability assessment in digital angiography: Application to moving targets
- 9 March 2023
- Published by Elsevier in Physica Medica
- Vol. 108, 102556
Open AccessSpatio-temporal generalized Model Observers methods for Low Contrast Detectability assessment in digital angiography: Application to moving targets
- 1 November 2021
- Published by Elsevier in Physica Medica
- Vol. 91, 28-42
A single phantom, a single statistical method for low-contrast detectability assessment
- 1 November 2021
- Published by Elsevier in Physica Medica
- Vol. 91, 28-42
A single phantom, a single statistical method for low-contrast detectability assessment
- 1 September 2017
- Published by Elsevier in Physica Medica
- Vol. 41, 58-70
Evaluation of a commercial Model Based Iterative reconstruction algorithm in computed tomography
- 1 September 2017
- Published by Elsevier in Physica Medica
- Vol. 41, 58-70
Evaluation of a commercial Model Based Iterative reconstruction algorithm in computed tomography