Development of Accelerated Test Method to Evaluate the Long-Term Thermal Performance of Fumed-Silica Vacuum Insulation Panels Using Accelerated Conditions
Open Access
Abstract
International standards for vacuum insulation panels (VIPs) include an accelerated test method and a minimum quality standard for evaluating their long-term thermal performance after 25 years. The accelerated test method consists of various tests according to the characteristics of the core material and requires six months (180 days) at minimum. Herein, we propose an accelerated method for determining the long-term thermal performance of fumed-silica VIPs by shortening the required time and simplifying the procedure. Highly accelerated conditions (80 °C and 70% Relative humidity (RH)) were set for the evaluation method, using the maximum temperature (80 °C) cited in international standards and compared with the accelerated test method under accelerated conditions (50 °C and 70% RH). The inner-pressure increase rate of the VIP samples after conditioning for approximately 70 days was similar to that after conditioning for 180 days under highly accelerated and accelerated conditions, respectively. In addition, the estimated long-term thermal conductivities of the fumed-silica VIP were derived as 0.0076 and 0.0054 W/m·K under highly accelerated and accelerated conditions, respectively. These accelerated methods can be used to produce fumed-silica VIPs with similar long-term thermal conductivities. Therefore, the accelerated test method for long-term thermal performance using the highly accelerated conditions can be evaluated using a test that involves conditioning the sample for approximately 70 days under 80 °C and 70% RH.Keywords
Funding Information
- Korea Institute of Construction Technology (20230276)
This publication has 23 references indexed in Scilit:
- Structure of vacuum insulation panel in building systemEnergy and Buildings, 2014
- Interior insulation retrofit of a historical brick wall using vacuum insulation panels: Hygrothermal numerical simulations and laboratory investigationsBuilding and Environment, 2014
- Gas permeation characteristics through heat-sealed flanges of vacuum insulation panelsVacuum, 2014
- Investigation of gas permeation through Al-metallized film for vacuum insulation panelsInternational Journal of Heat and Mass Transfer, 2013
- Aging effects on thermal properties and service life of vacuum insulation panelsJournal of Building Physics, 2011
- Vacuum insulation panels for building applications: A review and beyondEnergy and Buildings, 2010
- High-Performance Vacuum Insulation Panel: Development of Alternative Core MaterialsJournal of Cold Regions Engineering, 2008
- Vacuum insulation panels for building applicationEnergy and Buildings, 2005
- Permeation of Different Gases Through Foils used as Envelopes for Vacuum Insulation PanelsJournal of Thermal Envelope and Building Science, 2005
- Gas problem and gettering in sealed-off vacuum devicesVacuum, 1996