Minjung Bae
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Minjung Bae has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Jaesik Kang
Department of Building Energy Research, Korea Institute of Civil Engineering and Building Technology, Goyang 10223, Republic of Korea
8 shared publications - Hosang Ahn
Department of Building Energy Research, Korea Institute of Civil Engineering and Building Technology, Goyang 10223, Republic of Korea
4 shared publications - Gyeong-Seok Choi
Department of Building Energy Research, Korea Institute of Civil Engineering and Building Technology, Goyang 10223, Republic of Korea
3 shared publications - Sun Sook Kim
Department of Architecture, College of Engineering, Ajou University, Suwon 16499, Korea
2 shared publications - Doosam Song
School of Civil, Architectural Eng., and Landscape Architecture, Sungkyunkwan University, 2066 Seobu-ro, Suwon 16419, South Korea
1 shared publication Eun-Joo Oh
Bel Technology Co. Ltd
1 shared publication
Latest Publications
- Open Access
Transient Thermal Conductivity Minimum in Phenolic Foam Insulation: Closed-Cell Structural Dependence and Long-Term Aging Behavior
Closed-cell phenolic foam (PF) insulation is widely assumed to exhibit monotonically increasing thermal conductivity after cutting, driven by progressive blowing agent release. This study reports a previously uncharacterized behavior: a consistent decrease–minimum–rebound pattern in the days to weeks after cutting, defined here as the transient thermal conductivity minimum (TTCM). Using n-pentane-blown PF foam, thermal conductivity and mass were tracked under standard (23 °C) and accelerated aging conditions (70 °C, 110 °C; slicing per KS M ISO 11561), complemented by gas chromatography–flame ionization detection (GC-FID), attenuated total reflectance Fourier-transform infrared spectroscopy (ATR-FT-IR), thermogravimetric analysis/differential scanning calorimetry (TGA/DSC), and scanning electron microscopy (SEM). TTCM reductions of 3.8–16.7% were observed across all closed-cell specimens; a reference PF foam with cell-wall micro-perforations showed no TTCM, establishing intact closed-cell structure as a prerequisite. The mechanism is attributed to redistribution of dissolved n-pentane from the polymer matrix into the cell gas phase, thermodynamically favored by the proximity of n-pentane’s boiling point (36.07 °C) to the heat flow meter (HFM) hot plate temperature (33 °C). In the post-TTCM phase, thermal conductivity rises progressively as n-pentane is displaced by air; the rate of this rise is strongly dependent on diffusion path length. These results establish two mechanistically distinct aging stages and identify their respective governing factors.
Open AccessTransient Thermal Conductivity Minimum in Phenolic Foam Insulation: Closed-Cell Structural Dependence and Long-Term Aging Behavior
Closed-cell phenolic foam (PF) insulation is widely assumed to exhibit monotonically increasing thermal conductivity after cutting, driven by progressive blowing agent release. This study reports a previously uncharacterized behavior: a consistent decrease–minimum–rebound pattern in the days to weeks after cutting, defined here as the transient thermal conductivity minimum (TTCM). Using n-pentane-blown PF foam, thermal conductivity and mass were tracked under standard (23 °C) and accelerated aging conditions (70 °C, 110 °C; slicing per KS M ISO 11561), complemented by gas chromatography–flame ionization detection (GC-FID), attenuated total reflectance Fourier-transform infrared spectroscopy (ATR-FT-IR), thermogravimetric analysis/differential scanning calorimetry (TGA/DSC), and scanning electron microscopy (SEM). TTCM reductions of 3.8–16.7% were observed across all closed-cell specimens; a reference PF foam with cell-wall micro-perforations showed no TTCM, establishing intact closed-cell structure as a prerequisite. The mechanism is attributed to redistribution of dissolved n-pentane from the polymer matrix into the cell gas phase, thermodynamically favored by the proximity of n-pentane’s boiling point (36.07 °C) to the heat flow meter (HFM) hot plate temperature (33 °C). In the post-TTCM phase, thermal conductivity rises progressively as n-pentane is displaced by air; the rate of this rise is strongly dependent on diffusion path length. These results establish two mechanistically distinct aging stages and identify their respective governing factors.
- 23 June 2026
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 514, 142802
Formaldehyde emission behavior from phenolic foam insulation: Post-curing-driven internal retention independent of surface emission
- 23 June 2026
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 514, 142802
Formaldehyde emission behavior from phenolic foam insulation: Post-curing-driven internal retention independent of surface emission
- Open Access
Field Evidence of Envelope Renovation Impact on Heating Activation Temperature and Heating-Dependent Temperature Range in Apartments
Various studies on the envelope renovation of existing residential buildings have quantified energy savings effects across various climate conditions and building types yet have also reported discrepancies between predicted and actual energy savings performance. Given that identical technical improvements can yield substantially different actual outcomes depending on occupants’ behavioral adaptation patterns, renovation effect evaluation requires a multifaceted approach incorporating occupant behavioral changes. This case study empirically analyzed the effects of envelope renovation on occupants’ actual heating operation patterns. Envelope renovation effects applied to a 30-year-old apartment were analyzed by subdividing temperature conditions, with comparative evaluation using a non-renovated adjacent unit within the same building as a reference. While recognizing the inherent limitations of single-case analysis, this study presents a novel methodological framework for capturing subtle behavioral shifts through high-resolution temperature-specific analysis. Change-point models utilizing utility billing data were employed to analyze threshold temperature changes, and daily heating water-consumption estimation algorithms were applied to track heating pattern changes according to outdoor temperature variations. Results showed heating energy reduction despite more severe climate conditions post-renovation, with particularly pronounced savings under mild conditions. The upper limit of temperature ranges showing high heating dependency shifted downward from pre-renovation levels, improving to levels lower than the reference unit’s upper limit, demonstrating envelope performance enhancement effects. These results provide quantitative evidence that envelope improvements directly influence occupants’ heating decision-making criteria, though broader validation across multiple cases would strengthen these findings. This study quantifies envelope renovation effects not only in terms of energy savings, but also from the perspectives of occupant behavioral changes and comparison with reference units, presenting a novel evaluation methodology for effective energy efficiency improvements in aging buildings.
Open AccessField Evidence of Envelope Renovation Impact on Heating Activation Temperature and Heating-Dependent Temperature Range in Apartments
Various studies on the envelope renovation of existing residential buildings have quantified energy savings effects across various climate conditions and building types yet have also reported discrepancies between predicted and actual energy savings performance. Given that identical technical improvements can yield substantially different actual outcomes depending on occupants’ behavioral adaptation patterns, renovation effect evaluation requires a multifaceted approach incorporating occupant behavioral changes. This case study empirically analyzed the effects of envelope renovation on occupants’ actual heating operation patterns. Envelope renovation effects applied to a 30-year-old apartment were analyzed by subdividing temperature conditions, with comparative evaluation using a non-renovated adjacent unit within the same building as a reference. While recognizing the inherent limitations of single-case analysis, this study presents a novel methodological framework for capturing subtle behavioral shifts through high-resolution temperature-specific analysis. Change-point models utilizing utility billing data were employed to analyze threshold temperature changes, and daily heating water-consumption estimation algorithms were applied to track heating pattern changes according to outdoor temperature variations. Results showed heating energy reduction despite more severe climate conditions post-renovation, with particularly pronounced savings under mild conditions. The upper limit of temperature ranges showing high heating dependency shifted downward from pre-renovation levels, improving to levels lower than the reference unit’s upper limit, demonstrating envelope performance enhancement effects. These results provide quantitative evidence that envelope improvements directly influence occupants’ heating decision-making criteria, though broader validation across multiple cases would strengthen these findings. This study quantifies envelope renovation effects not only in terms of energy savings, but also from the perspectives of occupant behavioral changes and comparison with reference units, presenting a novel evaluation methodology for effective energy efficiency improvements in aging buildings.
- Open Access
- 16 October 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 75
Enhanced long-term thermal performance prediction of glass wool vacuum insulation panels: A comprehensive accelerated testing approach
- 16 October 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 75
Open AccessEnhanced long-term thermal performance prediction of glass wool vacuum insulation panels: A comprehensive accelerated testing approach
- Open Access
- 8 April 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (8) , 3307
Development and Analysis of Easy-to-Implement Green Retrofit Technologies for Windows to Reduce Heating Energy Use in Older Residential Buildings
Green remodeling and retrofitting are effective strategies for enhancing the sustainability of existing buildings. While green remodeling involves significant structural modifications, green retrofitting typically focuses on improving energy efficiency and reducing environmental impact. However, easy-to-implement green retrofit technologies can be particularly valuable for low-income communities, offering a more affordable way to upgrade residences without extensive renovations. This paper analyzed the effectiveness of newly developed, easy-to-implement green retrofit technologies for windows in reducing heating energy use and greenhouse gas emissions. We conducted experiments using secondary glazing and windproof materials to enhance the thermal insulation and air-tightness performance of a residential building. Subsequently, we simulated the effectiveness of these green retrofit technologies under various conditions for residential buildings. In addition, we analyzed utility bills using data collected from residents. Our findings demonstrated an average reduction of 10–15% in heating energy consumption through the implementation of these green retrofit technologies for windows in older residential buildings.
- 8 April 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (8) , 3307
Open AccessDevelopment and Analysis of Easy-to-Implement Green Retrofit Technologies for Windows to Reduce Heating Energy Use in Older Residential Buildings
Green remodeling and retrofitting are effective strategies for enhancing the sustainability of existing buildings. While green remodeling involves significant structural modifications, green retrofitting typically focuses on improving energy efficiency and reducing environmental impact. However, easy-to-implement green retrofit technologies can be particularly valuable for low-income communities, offering a more affordable way to upgrade residences without extensive renovations. This paper analyzed the effectiveness of newly developed, easy-to-implement green retrofit technologies for windows in reducing heating energy use and greenhouse gas emissions. We conducted experiments using secondary glazing and windproof materials to enhance the thermal insulation and air-tightness performance of a residential building. Subsequently, we simulated the effectiveness of these green retrofit technologies under various conditions for residential buildings. In addition, we analyzed utility bills using data collected from residents. Our findings demonstrated an average reduction of 10–15% in heating energy consumption through the implementation of these green retrofit technologies for windows in older residential buildings.
- Open Access
Development of Accelerated Test Method to Evaluate the Long-Term Thermal Performance of Fumed-Silica Vacuum Insulation Panels Using Accelerated Conditions
International standards for vacuum insulation panels (VIPs) include an accelerated test method and a minimum quality standard for evaluating their long-term thermal performance after 25 years. The accelerated test method consists of various tests according to the characteristics of the core material and requires six months (180 days) at minimum. Herein, we propose an accelerated method for determining the long-term thermal performance of fumed-silica VIPs by shortening the required time and simplifying the procedure. Highly accelerated conditions (80 °C and 70% Relative humidity (RH)) were set for the evaluation method, using the maximum temperature (80 °C) cited in international standards and compared with the accelerated test method under accelerated conditions (50 °C and 70% RH). The inner-pressure increase rate of the VIP samples after conditioning for approximately 70 days was similar to that after conditioning for 180 days under highly accelerated and accelerated conditions, respectively. In addition, the estimated long-term thermal conductivities of the fumed-silica VIP were derived as 0.0076 and 0.0054 W/m·K under highly accelerated and accelerated conditions, respectively. These accelerated methods can be used to produce fumed-silica VIPs with similar long-term thermal conductivities. Therefore, the accelerated test method for long-term thermal performance using the highly accelerated conditions can be evaluated using a test that involves conditioning the sample for approximately 70 days under 80 °C and 70% RH.
Open AccessDevelopment of Accelerated Test Method to Evaluate the Long-Term Thermal Performance of Fumed-Silica Vacuum Insulation Panels Using Accelerated Conditions
International standards for vacuum insulation panels (VIPs) include an accelerated test method and a minimum quality standard for evaluating their long-term thermal performance after 25 years. The accelerated test method consists of various tests according to the characteristics of the core material and requires six months (180 days) at minimum. Herein, we propose an accelerated method for determining the long-term thermal performance of fumed-silica VIPs by shortening the required time and simplifying the procedure. Highly accelerated conditions (80 °C and 70% Relative humidity (RH)) were set for the evaluation method, using the maximum temperature (80 °C) cited in international standards and compared with the accelerated test method under accelerated conditions (50 °C and 70% RH). The inner-pressure increase rate of the VIP samples after conditioning for approximately 70 days was similar to that after conditioning for 180 days under highly accelerated and accelerated conditions, respectively. In addition, the estimated long-term thermal conductivities of the fumed-silica VIP were derived as 0.0076 and 0.0054 W/m·K under highly accelerated and accelerated conditions, respectively. These accelerated methods can be used to produce fumed-silica VIPs with similar long-term thermal conductivities. Therefore, the accelerated test method for long-term thermal performance using the highly accelerated conditions can be evaluated using a test that involves conditioning the sample for approximately 70 days under 80 °C and 70% RH.
- Open Access
Determination of the Long-Term Thermal Performance of Foam Insulation Materials through Heat and Slicing Acceleration
Foam insulation materials are widely used in the construction industry due to their low thermal conductivity attributable to their microstructures and their low-conductivity blowing agents and affordability. In this study, we evaluate how the thermal performance of foam insulation materials used for the exterior walls of buildings, viz., extruded polystyrene (XPS), polyisocyanurate (PIR), and phenolic foam (PF), age over the life cycle of a building. To compare the aging of thermal performance during the life cycle of a building, each material was tested at 70 and 110 °C and with slicing acceleration according to EN and ISO standards. The thermal conductivity of each foam insulation material was measured using a heat flow meter at an operating temperature of 23 °C and converted into thermal resistance values. Different foam insulation materials have different aging procedures according to material-specific EN standards, while ISO 11561 applies the same procedure to all material classifications. Upon comparing the aged values according to ISO and EN standards to the initial values, the analysis showed a change rate of 23 to 26% in PIR and 18 to 20% in PF. In XPS, a rate of change of 10 to 23.8% was calculated. Our results indicated that the slicing acceleration induced a thermal resistance reduction rate about three times faster than aging at 70 °C. However, the long-term changed thermal resistance values of the foam insulation material applied via the calculating procedure specified in the ISO and EN standards were similar.
Open AccessDetermination of the Long-Term Thermal Performance of Foam Insulation Materials through Heat and Slicing Acceleration
Foam insulation materials are widely used in the construction industry due to their low thermal conductivity attributable to their microstructures and their low-conductivity blowing agents and affordability. In this study, we evaluate how the thermal performance of foam insulation materials used for the exterior walls of buildings, viz., extruded polystyrene (XPS), polyisocyanurate (PIR), and phenolic foam (PF), age over the life cycle of a building. To compare the aging of thermal performance during the life cycle of a building, each material was tested at 70 and 110 °C and with slicing acceleration according to EN and ISO standards. The thermal conductivity of each foam insulation material was measured using a heat flow meter at an operating temperature of 23 °C and converted into thermal resistance values. Different foam insulation materials have different aging procedures according to material-specific EN standards, while ISO 11561 applies the same procedure to all material classifications. Upon comparing the aged values according to ISO and EN standards to the initial values, the analysis showed a change rate of 23 to 26% in PIR and 18 to 20% in PF. In XPS, a rate of change of 10 to 23.8% was calculated. Our results indicated that the slicing acceleration induced a thermal resistance reduction rate about three times faster than aging at 70 °C. However, the long-term changed thermal resistance values of the foam insulation material applied via the calculating procedure specified in the ISO and EN standards were similar.
- Open Access
An Effective Expanded Graphite Coating on Polystyrene Bead for Improving Flame Retardancy
Although foamed plastic insulation is widely used in construction in the Korean market, it is vulnerable to fire. To improve the flame retardancy, the method of flame-retardant coating with the EG in water-soluble state on the surface of expanded polystyrene (EPS) beads has been widely used. However, polystyrene beads coated with a water-soluble flame retardant easily separate the coated flame retardant in manufacturing. In this study is devised a flame-retardant coating and two steps of coating process for adhering the flame-retardant coating film evenly to the surface of the polystyrene bead without exfoliation. It was analyzed whether a flame-retardant EPS (FR-EPS) with excellent flame retardancy could be manufactured using polystyrene beads coated in this way. Ten FR-EPS samples satisfied the HF-1 and V-0 levels in horizontal and vertical burning tests, respectively. The THR of eight FR-EPS samples for ten minutes did not exceed 8 MJ∙m−2 and the maximum HRR did not exceed 200 kW∙m−2 for more than ten consecutive seconds. FR-EPS passed the building material standard of semi-nonflammability in Korean regulations, in contrast to commercial EPS, which have not passed the semi-nonflammability standard. It was also analyzed how effective the designed coating is in this study, comparing it with composites that were planned to improve the flame resistance of polystyrene, as reported in the literature. Flame Retardancy Index (FRI) values of FR-EPS proved the “excellent” level and had higher values compared with other polystyrene composites. These results demonstrated that the coated EPS containing a water-soluble flame retardant manufactured from EG and two steps of application with the coating solution achieved fire safety standard regulations.
Open AccessAn Effective Expanded Graphite Coating on Polystyrene Bead for Improving Flame Retardancy
Although foamed plastic insulation is widely used in construction in the Korean market, it is vulnerable to fire. To improve the flame retardancy, the method of flame-retardant coating with the EG in water-soluble state on the surface of expanded polystyrene (EPS) beads has been widely used. However, polystyrene beads coated with a water-soluble flame retardant easily separate the coated flame retardant in manufacturing. In this study is devised a flame-retardant coating and two steps of coating process for adhering the flame-retardant coating film evenly to the surface of the polystyrene bead without exfoliation. It was analyzed whether a flame-retardant EPS (FR-EPS) with excellent flame retardancy could be manufactured using polystyrene beads coated in this way. Ten FR-EPS samples satisfied the HF-1 and V-0 levels in horizontal and vertical burning tests, respectively. The THR of eight FR-EPS samples for ten minutes did not exceed 8 MJ∙m−2 and the maximum HRR did not exceed 200 kW∙m−2 for more than ten consecutive seconds. FR-EPS passed the building material standard of semi-nonflammability in Korean regulations, in contrast to commercial EPS, which have not passed the semi-nonflammability standard. It was also analyzed how effective the designed coating is in this study, comparing it with composites that were planned to improve the flame resistance of polystyrene, as reported in the literature. Flame Retardancy Index (FRI) values of FR-EPS proved the “excellent” level and had higher values compared with other polystyrene composites. These results demonstrated that the coated EPS containing a water-soluble flame retardant manufactured from EG and two steps of application with the coating solution achieved fire safety standard regulations.
- Open Access
- 14 December 2020
- Published by MDPI AG in Sustainability
- Vol. 12 (24) , 10439
Analysis of the Calculation Method for the Thermal Transmittance of Double Windows Considering the Thermal Properties of the Air Cavity
The calculation method for the thermal transmittance (U-value) of double windows as specified by the Korean government (ISO 15099) is often inappropriate. To develop a more suitable calculation method, the thermal properties of the air cavity between the internal and external windows should be considered. Herein, seven cases of double windows were set up. The air cavities were designed in accordance with international standards and computational fluid dynamics (CFD) and used for the calculation of the U-values of the double windows according to ISO 15099 and 10077. All the calculated U-values were compared with experimentally obtained values. In accordance with the ISO 10077-1 method, the thermal resistance of the air cavity calculated using CFD could produce double window U-values that are similar to the experimentally obtained values. In most cases, the difference between the theoretical and experimental U-values was 5% and less than 0.14 W·m−2·K−1, implying that the U-values calculated using CFD and the ISO 10077-1 method are approximately equal to the experimentally obtained U-values. Korean regulations do not include ISO 10077-1 for double-window assessment. However, these criteria can provide a solution in improving the accuracy of the calculation of the overall thermal transmittance of double windows.
- 14 December 2020
- Published by MDPI AG in Sustainability
- Vol. 12 (24) , 10439
Open AccessAnalysis of the Calculation Method for the Thermal Transmittance of Double Windows Considering the Thermal Properties of the Air Cavity
The calculation method for the thermal transmittance (U-value) of double windows as specified by the Korean government (ISO 15099) is often inappropriate. To develop a more suitable calculation method, the thermal properties of the air cavity between the internal and external windows should be considered. Herein, seven cases of double windows were set up. The air cavities were designed in accordance with international standards and computational fluid dynamics (CFD) and used for the calculation of the U-values of the double windows according to ISO 15099 and 10077. All the calculated U-values were compared with experimentally obtained values. In accordance with the ISO 10077-1 method, the thermal resistance of the air cavity calculated using CFD could produce double window U-values that are similar to the experimentally obtained values. In most cases, the difference between the theoretical and experimental U-values was 5% and less than 0.14 W·m−2·K−1, implying that the U-values calculated using CFD and the ISO 10077-1 method are approximately equal to the experimentally obtained U-values. Korean regulations do not include ISO 10077-1 for double-window assessment. However, these criteria can provide a solution in improving the accuracy of the calculation of the overall thermal transmittance of double windows.
- 23 October 2017
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 38 (12) , 180
A Numerical Study of the Thermal Characteristics of an Air Cavity Formed by Window Sashes in a Double Window
- 23 October 2017
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 38 (12) , 180
A Numerical Study of the Thermal Characteristics of an Air Cavity Formed by Window Sashes in a Double Window