Quantitative contrast‐enhanced MRI with superparamagnetic nanoparticles using ultrashort time‐to‐echo pulse sequences
Open Access
- 28 August 2014
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 74 (2) , 431-441
Abstract
Purpose: Conventional MRI using contrast agents is semiquantitative because it is inherently sensitive to extravoxular susceptibility artifacts, field inhomogeneity, partial voluming, perivascular effects, and motion/flow artifacts. Herein we demonstrate a quantitative contrast‐enhanced MRI technique using ultrashort time‐to‐echo pulse sequences for measuring clinically relevant concentrations of ferumoxytol, a superparamagnetic iron oxide nanoparticle contrast agent with high sensitivity and precision in vitro and in vivo.Methods: The method achieves robust, reproducible results by using rapid signal acquisition at ultrashort time‐to‐echo (UTE) to produce positive contrast images with pure T1 weighting and little T2* decay. The spoiled gradient echo equation is used to transform UTE intensities directly into concentration using experimentally determined relaxivity constants and image acquisition parameters.Results: A multiparametric optimization of acquisition parameters revealed an optimal zone capable of producing high‐fidelity measurements. Clinically relevant intravascular concentrations of ferumoxytol were measured longitudinally in mice with high sensitivity and precision (∼7.1% error). MRI measurements were independently validated by elemental iron analysis of sequential blood draws. Automated segmentation of ferumoxytol concentration yielded high quality three‐dimensional images for visualization of perfusion.Conclusions: This ability to longitudinally quantify blood pool CA concentration is unique to quantitative UTE contrast‐enhanced (QUTE‐CE) MRI and makes QUTE‐CE MRI competitive with nuclear imaging. Magn Reson Med 74:431–441, 2015.Keywords
This publication has 39 references indexed in Scilit:
- GBM Volumetry using the 3D Slicer Medical Image Computing PlatformScientific Reports, 2013
- Optimization of iron oxide nanoparticle detection using ultrashort echo time pulse sequences: Comparison of T1, T2*, and synergistic T1 − T2* contrast mechanismsMagnetic Resonance in Medicine, 2011
- Quantification of SPIO nanoparticles in vivo using the finite perturber methodMagnetic Resonance in Medicine, 2010
- Optimization and validation of methods for mapping of the radiofrequency transmit field at 3TMagnetic Resonance in Medicine, 2010
- Impact of field strength and iron oxide nanoparticle concentration on the linearity and diagnostic accuracy of off‐resonance imagingNMR in Biomedicine, 2008
- Uncertainty and bias in contrast concentration measurements using spoiled gradient echo pulse sequencesPhysics in Medicine & Biology, 2008
- Magnetic nanoparticles for MR imaging: agents, techniques and cardiovascular applicationsBasic Research in Cardiology, 2008
- Technology Insight: novel imaging of molecular targets is an emerging area crucial to the development of targeted drugsNature Clinical Practice Oncology, 2008
- Molecular imaging in drug discovery and developmentNature Reviews Drug Discovery, 2003
- Theory of proton relaxation induced by superparamagnetic particlesThe Journal of Chemical Physics, 1999