Finite element analysis of the biomechanical interaction between coronary sinus and proximal anchoring stent in coronary sinus annuloplasty
Authors:
- 6 February 2013
- journal article
- research article
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 17 (14) , 1617-1629
Abstract
Recent clinical studies of the percutaneous transvenous mitral annuloplasty (PTMA) devices have shown a short-term reduction of mitral regurgitation after implantation. However, adverse events associated with the devices such as compression and perforation of vessel branches, device migration and fracture were reported. In this study, a finite element analysis was carried out to investigate the biomechanical interaction between the proximal anchor stent of a PTMA device and the coronary sinus (CS) vessel in three steps including: (i) the stent release and contact with the CS wall, (ii) the axial pull t the stent connector and (iii) the pressure inflation of the vessel wall. To investigate the impact of the material properties of tissues and stents on the interactive responses, the CS vessel was modelled with human and porcine material properties, and the proximal stent was modelled with two different Nitinol materials with one being stiffer than the other. The results indicated that the vessel wall stresses and contact forces imposed by the stents were much higher in the human model than the porcine model. However, the mechanical differences induced by the two stent types were relatively small. The softer stent exhibited a better fatigue safety factor when deployed in the human model than in the porcine model. These results underscored the importance of the CS tissue mechanical properties. Vessel wall stress and stent radial force obtained in the human model were higher than those obtained in the porcine model, which also brought up questions as to the validity of using the porcine model to assess device mechanical function. The quantification of these biomechanical interactions can offer scientific insight into the development and optimisation of the PTMA device design.Keywords
This publication has 32 references indexed in Scilit:
- Comparison of biaxial mechanical properties of coronary sinus tissues from porcine, ovine and aged human speciesJournal of the Mechanical Behavior of Biomedical Materials, 2012
- Transcatheter Implantation of the MONARC Coronary Sinus Device for Mitral RegurgitationJACC: Cardiovascular Interventions, 2011
- Characterization of the mechanical properties of the coronary sinus for percutaneous transvenous mitral annuloplastyActa Biomaterialia, 2010
- Percutaneous mitral annuloplasty device leaves free access to cardiac veins for resynchronization therapyCatheterization and Cardiovascular Interventions, 2009
- Percutaneous Transvenous Mitral AnnuloplastyCirculation: Cardiovascular Interventions, 2009
- Cardiac veins: A review of the literatureClinical Anatomy, 2008
- Computational mechanics of Nitinol stent graftsJournal of Biomechanics, 2008
- Percutaneous mitral valve annuloplasty for ischemic mitral regurgitation: First in man experience with a temporary implantCatheterization and Cardiovascular Interventions, 2007
- FDA Recommendations for Nitinol Stent and Endovascular Graft Fatigue Characterization and Fracture ReportingJournal of ASTM International, 2006
- Prevalence and correlates of mitral regurgitation in a population-based sample (the Strong Heart Study)∗∗The views expressed in this study are those of the authors and do not necessarily reflect those of the Indian Health Service.The American Journal of Cardiology, 2001