Wei Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wei Sun has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Thuy Pham
Tissue Mechanics Laboratory, Biomedical Engineering Program and Mechanical Engineering Department, University of Connecticut, Storrs, CT 06269, United States
6 shared publicationsCaitlin Martin
Tissue Mechanics Laboratory, Biomedical Engineering Program and Mechanical Engineering Department, University of Connecticut, Storrs, CT 06269, United States
5 shared publicationsEric Sirois
University of Connecticut
5 shared publicationsQian Wang
Tissue Mechanics Laboratory Biomedical Engineering Program and Department of Mechanical Engineering University of Connecticut Storrs Connecticut 06269
5 shared publications- Kewei Li
University of Connecticut, Storrs, CT
3 shared publications Charles Primiano
Department of Cardiology, Hartford Hospital, Hartford, USA
2 shared publications
Latest Publications
- 1 December 2013
- Published by Elsevier in Acta Biomaterialia
- Vol. 9 (12) , 9392-9400
Predictive biomechanical analysis of ascending aortic aneurysm rupture potential
- 1 December 2013
- Published by Elsevier in Acta Biomaterialia
- Vol. 9 (12) , 9392-9400
Predictive biomechanical analysis of ascending aortic aneurysm rupture potential
- 1 August 2013
- Published by Elsevier in Acta Biomaterialia
- Vol. 9 (8) , 7927-7936
Biomechanical characterization of ascending aortic aneurysm with concomitant bicuspid aortic valve and bovine aortic arch
- 1 August 2013
- Published by Elsevier in Acta Biomaterialia
- Vol. 9 (8) , 7927-7936
Biomechanical characterization of ascending aortic aneurysm with concomitant bicuspid aortic valve and bovine aortic arch
- 27 July 2013
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 102 (7) , 2365-2374
Quantification of structural compliance of aged human and porcine aortic root tissues
The structural compliance of the aortic root has a significant implication for valve procedures such as transcatheter aortic valve implantation and valve‐sparing aortic root replacement. However, a detailed quantification of human aortic root structural compliance, particularly in different regions, has been incomplete. In this study, the structural properties of human aortic roots (81 ± 8.74 years, n = 10) were characterized and compared with those of porcine ones (6–9 months, n = 10) using a vessel pressure‐inflation test. The test involved tracking three‐dimensional deformation of the markers affixed on the different surface regions of the aortic roots, including the three sinuses: the noncoronary sinus (NCS), the left‐coronary sinus (LCS), and the right‐coronary sinus (RCS), and at three regions along the longitudinal direction of each sinus: the upper sinus (US), the middle sinus (MS), and the lower sinus (LS), and the ascending aorta (AA) region above the NCS. We found that tissue stiffness in physiological pressure range was similar among the three human sinuses. A variation in regional structural stiffness of human aorta was observed. In the circumferential direction, the LS regions were the stiffest in the LCS and RCS, whereas NCS had relatively uniform stiffness. In the longitudinal direction, the human AA regions were more compliant than all sinuses. There was a significant difference in tissue stiffness between human and porcine aortic tissues, suggesting that the mechanical properties of porcine tissues may not be analogous to aged human ones. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 102A: 2365–2374, 2014.
- 27 July 2013
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 102 (7) , 2365-2374
Quantification of structural compliance of aged human and porcine aortic root tissues
The structural compliance of the aortic root has a significant implication for valve procedures such as transcatheter aortic valve implantation and valve‐sparing aortic root replacement. However, a detailed quantification of human aortic root structural compliance, particularly in different regions, has been incomplete. In this study, the structural properties of human aortic roots (81 ± 8.74 years, n = 10) were characterized and compared with those of porcine ones (6–9 months, n = 10) using a vessel pressure‐inflation test. The test involved tracking three‐dimensional deformation of the markers affixed on the different surface regions of the aortic roots, including the three sinuses: the noncoronary sinus (NCS), the left‐coronary sinus (LCS), and the right‐coronary sinus (RCS), and at three regions along the longitudinal direction of each sinus: the upper sinus (US), the middle sinus (MS), and the lower sinus (LS), and the ascending aorta (AA) region above the NCS. We found that tissue stiffness in physiological pressure range was similar among the three human sinuses. A variation in regional structural stiffness of human aorta was observed. In the circumferential direction, the LS regions were the stiffest in the LCS and RCS, whereas NCS had relatively uniform stiffness. In the longitudinal direction, the human AA regions were more compliant than all sinuses. There was a significant difference in tissue stiffness between human and porcine aortic tissues, suggesting that the mechanical properties of porcine tissues may not be analogous to aged human ones. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 102A: 2365–2374, 2014.
- 2 July 2013
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 41 (12) , 2565-2574
Age-Dependent Ascending Aorta Mechanics Assessed Through Multiphase CT
Quantification of the age- and gender-specific in vivo mechanical characteristics of the ascending aorta (AA) will allow for identification of abnormalities aside from changes brought on by aging alone. Multiphase clinical CT scans of 45 male patients between the ages of 30 and 79 years were analyzed to assess age-dependent in vivo AA characteristics. The three-dimensional AA geometry for each patient was reconstructed from the CT scans for 9–10 phases throughout the cardiac cycle. The AA circumference was measured during each phase and was used to determine the corresponding diameter, circumferential strain, and wall tension at each phase. The pressure-strain modulus was also determined for each patient. The mean diastolic AA diameter was significantly smaller among young (42.6 ± 5.2 years) at 29.9 ± 2.8 mm than old patients (69.0 ± 5.2 years) at 33.2 ± 3.2 mm. The circumferential AA strain from end-diastole to peak-systole decreased from 0.092 ± 0.03 in young to 0.056 ± 0.03 in old patients. The pressure–strain modulus increased two-fold from 68.4 ± 30.5 kPa in young to 162.0 ± 93.5 kPa in old patients, and the systolic AA wall tension increased from 268.5 ± 31.3 kPa in young to 304.9 ± 49.2 kPa in old patients. The AA dilates and stiffens with aging which increases the vessel wall tension, likely predisposing aneurysm and dissection.
- 2 July 2013
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 41 (12) , 2565-2574
Age-Dependent Ascending Aorta Mechanics Assessed Through Multiphase CT
Quantification of the age- and gender-specific in vivo mechanical characteristics of the ascending aorta (AA) will allow for identification of abnormalities aside from changes brought on by aging alone. Multiphase clinical CT scans of 45 male patients between the ages of 30 and 79 years were analyzed to assess age-dependent in vivo AA characteristics. The three-dimensional AA geometry for each patient was reconstructed from the CT scans for 9–10 phases throughout the cardiac cycle. The AA circumference was measured during each phase and was used to determine the corresponding diameter, circumferential strain, and wall tension at each phase. The pressure-strain modulus was also determined for each patient. The mean diastolic AA diameter was significantly smaller among young (42.6 ± 5.2 years) at 29.9 ± 2.8 mm than old patients (69.0 ± 5.2 years) at 33.2 ± 3.2 mm. The circumferential AA strain from end-diastole to peak-systole decreased from 0.092 ± 0.03 in young to 0.056 ± 0.03 in old patients. The pressure–strain modulus increased two-fold from 68.4 ± 30.5 kPa in young to 162.0 ± 93.5 kPa in old patients, and the systolic AA wall tension increased from 268.5 ± 31.3 kPa in young to 304.9 ± 49.2 kPa in old patients. The AA dilates and stiffens with aging which increases the vessel wall tension, likely predisposing aneurysm and dissection.
- 6 February 2013
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 17 (14) , 1617-1629
Finite element analysis of the biomechanical interaction between coronary sinus and proximal anchoring stent in coronary sinus annuloplasty
Recent clinical studies of the percutaneous transvenous mitral annuloplasty (PTMA) devices have shown a short-term reduction of mitral regurgitation after implantation. However, adverse events associated with the devices such as compression and perforation of vessel branches, device migration and fracture were reported. In this study, a finite element analysis was carried out to investigate the biomechanical interaction between the proximal anchor stent of a PTMA device and the coronary sinus (CS) vessel in three steps including: (i) the stent release and contact with the CS wall, (ii) the axial pull t the stent connector and (iii) the pressure inflation of the vessel wall. To investigate the impact of the material properties of tissues and stents on the interactive responses, the CS vessel was modelled with human and porcine material properties, and the proximal stent was modelled with two different Nitinol materials with one being stiffer than the other. The results indicated that the vessel wall stresses and contact forces imposed by the stents were much higher in the human model than the porcine model. However, the mechanical differences induced by the two stent types were relatively small. The softer stent exhibited a better fatigue safety factor when deployed in the human model than in the porcine model. These results underscored the importance of the CS tissue mechanical properties. Vessel wall stress and stent radial force obtained in the human model were higher than those obtained in the porcine model, which also brought up questions as to the validity of using the porcine model to assess device mechanical function. The quantification of these biomechanical interactions can offer scientific insight into the development and optimisation of the PTMA device design.
- 6 February 2013
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 17 (14) , 1617-1629
Finite element analysis of the biomechanical interaction between coronary sinus and proximal anchoring stent in coronary sinus annuloplasty
Recent clinical studies of the percutaneous transvenous mitral annuloplasty (PTMA) devices have shown a short-term reduction of mitral regurgitation after implantation. However, adverse events associated with the devices such as compression and perforation of vessel branches, device migration and fracture were reported. In this study, a finite element analysis was carried out to investigate the biomechanical interaction between the proximal anchor stent of a PTMA device and the coronary sinus (CS) vessel in three steps including: (i) the stent release and contact with the CS wall, (ii) the axial pull t the stent connector and (iii) the pressure inflation of the vessel wall. To investigate the impact of the material properties of tissues and stents on the interactive responses, the CS vessel was modelled with human and porcine material properties, and the proximal stent was modelled with two different Nitinol materials with one being stiffer than the other. The results indicated that the vessel wall stresses and contact forces imposed by the stents were much higher in the human model than the porcine model. However, the mechanical differences induced by the two stent types were relatively small. The softer stent exhibited a better fatigue safety factor when deployed in the human model than in the porcine model. These results underscored the importance of the CS tissue mechanical properties. Vessel wall stress and stent radial force obtained in the human model were higher than those obtained in the porcine model, which also brought up questions as to the validity of using the porcine model to assess device mechanical function. The quantification of these biomechanical interactions can offer scientific insight into the development and optimisation of the PTMA device design.
- 1 February 2013
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 18, 81-89
Characterization of aortic tissue cutting process: Experimental investigation using porcine ascending aorta
- 1 February 2013
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 18, 81-89
Characterization of aortic tissue cutting process: Experimental investigation using porcine ascending aorta
- 17 November 2012
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 41 (3) , 577-586
Quantification of Biomechanical Interaction of Transcatheter Aortic Valve Stent Deployed in Porcine and Ovine Hearts
Success of the deployment and function in transcatheter aortic valve replacement is heavily reliant on the tissue–stent interaction. The present study quantified important tissue–stent contact variables of self-expanding transcatheter aortic valve stents when deployed into ovine and porcine aortic roots, such as the stent radial expansion force, stent pullout force, the annulus deformation response and the coefficient of friction on the tissue–stent contact interface. Braided Nitinol stents were developed, tested to determine stent crimped diameter vs. stent radial force from a stent crimp experiment, and deployed in vitro to quantify stent pullout, aortic annulus deformation, and the coefficient of friction between the stent and the aortic tissue from an aortic root–stent interaction experiment. The results indicated that when crimped at body temperature from 26 mm to 19, 21 and 23 mm stent radial forces were approximately 30–40% higher than those crimped at room temperature. Coefficients of friction leveled to approximately 0.10 ± 0.01 as stent wire diameter increased and annulus size decreased from 23 to 19 mm. Regardless of aortic annulus size and species tested, it appeared that a minimum of about 2.5 mm in annular dilatation, caused by about 60 N of radial force from stent expansion, was needed to anchor the stent against a pullout into the left ventricle. The study of the contact biomechanics in animal aortic tissues may help us better understand characteristics of tissue–stent interactions and quantify the baseline responses of non-calcified aortic tissues.
- 17 November 2012
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 41 (3) , 577-586
Quantification of Biomechanical Interaction of Transcatheter Aortic Valve Stent Deployed in Porcine and Ovine Hearts
Success of the deployment and function in transcatheter aortic valve replacement is heavily reliant on the tissue–stent interaction. The present study quantified important tissue–stent contact variables of self-expanding transcatheter aortic valve stents when deployed into ovine and porcine aortic roots, such as the stent radial expansion force, stent pullout force, the annulus deformation response and the coefficient of friction on the tissue–stent contact interface. Braided Nitinol stents were developed, tested to determine stent crimped diameter vs. stent radial force from a stent crimp experiment, and deployed in vitro to quantify stent pullout, aortic annulus deformation, and the coefficient of friction between the stent and the aortic tissue from an aortic root–stent interaction experiment. The results indicated that when crimped at body temperature from 26 mm to 19, 21 and 23 mm stent radial forces were approximately 30–40% higher than those crimped at room temperature. Coefficients of friction leveled to approximately 0.10 ± 0.01 as stent wire diameter increased and annulus size decreased from 23 to 19 mm. Regardless of aortic annulus size and species tested, it appeared that a minimum of about 2.5 mm in annular dilatation, caused by about 60 N of radial force from stent expansion, was needed to anchor the stent against a pullout into the left ventricle. The study of the contact biomechanics in animal aortic tissues may help us better understand characteristics of tissue–stent interactions and quantify the baseline responses of non-calcified aortic tissues.
- 4 September 2012
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 12 (4) , 645-655
Modeling of long-term fatigue damage of soft tissue with stress softening and permanent set effects
One of the major failure modes of bioprosthetic heart valves is non-calcific structural deterioration due to fatigue of the tissue leaflets. Experimental methods to characterize tissue fatigue properties are complex and time-consuming. A constitutive fatigue model that could be calibrated by isolated material tests would be ideal for investigating the effects of more complex loading conditions. However, there is a lack of tissue fatigue damage models in the literature. To address these limitations, in this study, a phenomenological constitutive model was developed to describe the stress softening and permanent set effects of tissue subjected to long-term cyclic loading. The model was used to capture characteristic uniaxial fatigue data for glutaraldehyde-treated bovine pericardium and was then implemented into finite element software. The simulated fatigue response agreed well with the experimental data and thus demonstrates feasibility of this approach.
- 4 September 2012
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 12 (4) , 645-655
Modeling of long-term fatigue damage of soft tissue with stress softening and permanent set effects
One of the major failure modes of bioprosthetic heart valves is non-calcific structural deterioration due to fatigue of the tissue leaflets. Experimental methods to characterize tissue fatigue properties are complex and time-consuming. A constitutive fatigue model that could be calibrated by isolated material tests would be ideal for investigating the effects of more complex loading conditions. However, there is a lack of tissue fatigue damage models in the literature. To address these limitations, in this study, a phenomenological constitutive model was developed to describe the stress softening and permanent set effects of tissue subjected to long-term cyclic loading. The model was used to capture characteristic uniaxial fatigue data for glutaraldehyde-treated bovine pericardium and was then implemented into finite element software. The simulated fatigue response agreed well with the experimental data and thus demonstrates feasibility of this approach.
- 18 July 2012
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 41 (1) , 142-153
Finite Element Modeling of Mitral Valve Dynamic Deformation Using Patient-Specific Multi-Slices Computed Tomography Scans
The objective of this study was to develop a patient-specific finite element (FE) model of a human mitral valve. The geometry of the mitral valve was reconstructed from multi-slice computed tomography (MSCT) scans at middle diastole with distinguishable mitral leaflet thickness, chordal origins, chordal insertion points, and papillary muscle locations. Mitral annulus and papillary muscle dynamic motions were also quantified from MSCT scans and prescribed as boundary conditions for the FE simulation. Material properties of the human mitral leaflet tissues were obtained from biaxial tests and characterized by an anisotropic hyperelastic material model. In vivo dynamic closing of the mitral valve was simulated. The closed shape of the mitral valve output from the simulation was similar to the mitral valve geometry reconstructed from MSCT images at middle systole. Forces from the anterolateral and posteromedial papillary muscle groups at middle systole were 4.51 N and 5.17 N, respectively. The average maximum principal stress of the midsection of the anterior mitral leaflet was approximately 160 kPa at the systolic peak. Results demonstrated that the developed FE model could closely replicate in vivo mitral valve dynamic motion during middle diastole and systole. This model may serve as a basis for utilizing computational simulations to obtain a better understanding of mitral valve mechanics, disease and surgical repair.
- 18 July 2012
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 41 (1) , 142-153
Finite Element Modeling of Mitral Valve Dynamic Deformation Using Patient-Specific Multi-Slices Computed Tomography Scans
The objective of this study was to develop a patient-specific finite element (FE) model of a human mitral valve. The geometry of the mitral valve was reconstructed from multi-slice computed tomography (MSCT) scans at middle diastole with distinguishable mitral leaflet thickness, chordal origins, chordal insertion points, and papillary muscle locations. Mitral annulus and papillary muscle dynamic motions were also quantified from MSCT scans and prescribed as boundary conditions for the FE simulation. Material properties of the human mitral leaflet tissues were obtained from biaxial tests and characterized by an anisotropic hyperelastic material model. In vivo dynamic closing of the mitral valve was simulated. The closed shape of the mitral valve output from the simulation was similar to the mitral valve geometry reconstructed from MSCT images at middle systole. Forces from the anterolateral and posteromedial papillary muscle groups at middle systole were 4.51 N and 5.17 N, respectively. The average maximum principal stress of the midsection of the anterior mitral leaflet was approximately 160 kPa at the systolic peak. Results demonstrated that the developed FE model could closely replicate in vivo mitral valve dynamic motion during middle diastole and systole. This model may serve as a basis for utilizing computational simulations to obtain a better understanding of mitral valve mechanics, disease and surgical repair.
- 1 July 2012
- Published by Elsevier in Journal of Biomechanics
- Vol. 45 (11) , 1965-1971
Patient-specific modeling of biomechanical interaction in transcatheter aortic valve deployment
- 1 July 2012
- Published by Elsevier in Journal of Biomechanics
- Vol. 45 (11) , 1965-1971
Patient-specific modeling of biomechanical interaction in transcatheter aortic valve deployment