3D MRI‐based tumor delineation of ocular melanoma and its comparison with conventional techniques
Authors:
- Inder K DaftariIDInder K Daftari
- Elsa AghaianEAElsa Aghaian
- Joan M. O'BRienJOJoan M. O'BRien
- William DillonWDWilliam Dillon
- Theodore L. PhillipsTPTheodore L. Phillips
- 18 October 2005
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 32 (11) , 3355-3362
Abstract
The aim of this study is to (1) compare the delineation of the tumor volume for ocular melanoma on high‐resolution three‐dimensional (3D) T2‐weighted fast spin echo magnetic resonance imaging (MRI) images with conventional techniques of A‐ and B‐scan ultrasound, transcleral illumination, and placement of tantalum markers around tumor base and (2) to evaluate whether the surgically placed marker ring tumor delineation can be replaced by 3D MRI based tumor delineation. High‐resolution 3D T2‐weighted fast spin echo (3D FSE) MRI scans were obtained for 60 consecutive ocular melanoma patients using a 1.5 T MRI (GE Medical Systems, Milwaukee, WI), in a standard head coil. These patients were subsequently treated with proton beam therapy at the UC Davis Cyclotron, Davis, CA. The tumor was delineated by placement of tantalum rings (radio‐opaque markers) around the tumor periphery as defined by pupillary transillumination during surgery. A point light source, placed against the sclera, was also used to confirm ring agreement with indirect ophthalmoscopy. When necessary, intraoperative ultrasound was also performed. The patients were planned using EYEPLAN software and the tumor volumes were obtained. For analysis, the tumors were divided into four categories based on tumor height and basal diameter. In order to assess the impact of high‐resolution 3D T2 FSE MRI, the tumor volumes were outlined on the MRI scans by two independent observers and the tumor volumes calculated for each patient. Six (10%) of 60 patients had tumors, which were not visible on 3D MRI images. These six patients had tumors with tumor heights . A small intraobserver variation with a mean of was seen in tumor volumes delineated by 3D T2 FSE MR images. The ratio of tumor volumes measured on MRI to EYEPLAN for the largest to the smallest tumor volumes varied between 0.993 and 1.02 for 54 patients. The tumor volumes measured directly on 3D T2 FSE MRI ranged from 4.03 to with a mean of . The tumor shapes obtained from 3D T2 FSE MR images were comparable to the tumor shapes obtained using EYEPLAN software. The demonstration of intraocular tumor volumes with the high‐resolution 3D fast spin echo T2 weighted MRI is excellent and provides additional information on tumor shape. We found a high degree of accuracy for tumor volumes with direct MRI volumetric measurements in uveal melanoma patients. In some patients with extra large tumors, the tumor base and shape was modified, because of the additional information obtained from 3D T2 FSE MR images.Keywords
Funding Information
- R01 Department of Ophthalmology (EY02162)
This publication has 22 references indexed in Scilit:
- Calculated tumour volume as a prognostic parameter for survival in choroidal melanomasEye, 2004
- Eye retention after proton beam radiotherapy for uveal melanomaInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2003
- Tumor Basal Area and Metastatic Death After Proton Beam Irradiation for Choroidal MelanomaArchives of Ophthalmology (1950), 2003
- Uveal MelanomaArchives of Ophthalmology (1950), 1997
- Results of heavy ion radiotherapyRadiation and Environmental Biophysics, 1995
- The 62 MeV proton beam for the treatment of ocular melanoma at ClatterbridgeBritish Journal of Radiology, 1993
- MRI and intraocular tamponade mediaNeuroradiology, 1993
- Intraocular Recurrence of Uveal Melanoma after Proton Beam IrradiationOphthalmology, 1992
- Magnetic Resonance Imaging in the Evaluation and Differentiation of Uveal MelanomaOphthalmology, 1987
- Planning proton therapy of the eyeMedical Physics, 1983