Inder K. Daftari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Inder K. Daftari has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Kavita K. Mishra
Department of Radiation Oncology, University of California, San Francisco, San Francisco, CA, USA
3 shared publications Theodore L. Phillips
Department of Radiation Oncology, University of California-San Francisco, 1600 Divisadero Street, San Francisco, California 94143-1708
3 shared publicationsAndrew A Kao
Department of Ophthalmology, University of California, San Francisco, San Francisco, CA, USA
1 shared publication- Armin R. Afshar
Ocular Oncology Service, Department of Ophthalmology, Wayne & Gladys Valley Center for Vision, University of California, San Francisco, San Francisco, CA, USA
1 shared publication - Bertil Damato
Ocular Oncology Service, Moorfields Eye Hospital, London, United Kingdom
1 shared publication D. A. Larson
1 shared publication
Latest Publications
- 3 August 2015
- Published by Taylor & Francis in Expert Review of Ophthalmology
- Vol. 10 (6) , 577-585
Proton beam radiotherapy for uveal melanoma
Proton beam radiotherapy for uveal melanoma can be administered as primary treatment, as salvage therapy for a recurrent tumor, as neoadjuvant therapy prior to surgical resection, or as adjuvant therapy after surgical resection. Of all eye-conserving forms of uveal melanoma treatment, proton beam is associated with the lowest overall risk of local tumor recurrence. The physical properties of proton beams make it possible to deliver high-radiation doses to tumors with relative sparing of adjacent tissues from collateral damage. The chances of survival, ocular conservation, visual preservation, and avoidance of iatrogenic morbidity depend greatly on the tumor size, location, and extent. When treating side effects and/or complications, it is helpful to consider whether the etiology is collateral damage to healthy ocular tissues, such as the optic disc, or exudation and release of angiogenic factors from the irradiated tumor, possibly resulting in neovascular glaucoma (‘toxic tumor syndrome’). As with any therapy, it is important to treat not only the tumor but the patient, addressing all needs and concerns with appropriate psychological counseling.
- 3 August 2015
- Published by Taylor & Francis in Expert Review of Ophthalmology
- Vol. 10 (6) , 577-585
Proton beam radiotherapy for uveal melanoma
Proton beam radiotherapy for uveal melanoma can be administered as primary treatment, as salvage therapy for a recurrent tumor, as neoadjuvant therapy prior to surgical resection, or as adjuvant therapy after surgical resection. Of all eye-conserving forms of uveal melanoma treatment, proton beam is associated with the lowest overall risk of local tumor recurrence. The physical properties of proton beams make it possible to deliver high-radiation doses to tumors with relative sparing of adjacent tissues from collateral damage. The chances of survival, ocular conservation, visual preservation, and avoidance of iatrogenic morbidity depend greatly on the tumor size, location, and extent. When treating side effects and/or complications, it is helpful to consider whether the etiology is collateral damage to healthy ocular tissues, such as the optic disc, or exudation and release of angiogenic factors from the irradiated tumor, possibly resulting in neovascular glaucoma (‘toxic tumor syndrome’). As with any therapy, it is important to treat not only the tumor but the patient, addressing all needs and concerns with appropriate psychological counseling.
- 13 September 2010
- Published by Wiley in Medical Physics
- Vol. 37 (10) , 5199-5207
Fundus image fusion in EYEPLAN software: An evaluation of a novel technique for ocular melanoma radiation treatment planning
Purpose: The purpose of this study is to evaluate a novel approach for treatment planning using digital fundus image fusion inEYEPLAN for proton beam radiation therapy (PBRT) planning for ocular melanoma. The authors used a prototype version of EYEPLANsoftware, which allows for digital registration of high-resolution fundus photographs. The authors examined the improvement in tumor localization by replanning with the addition of fundus photo superimposition in patients with macular area tumors. Methods: The new version ofEYEPLAN (v3.05) software allows for the registration of fundus photographs as a background image. This is then used in conjunction with clinical examination, tantalum marker clips, surgeon’s mapping, and ultrasound to draw the tumor contour accurately. In order to determine if the fundus image superimposition helps in tumor delineation and treatment planning, the authors identified 79 patients with choroidal melanoma in the macular location that were treated with PBRT. All patients were treated to a dose of 56 GyE in four fractions. The authors reviewed and replanned all 79 macular melanoma cases with superimposition of pretreatment and post-treatment fundus imaging in the new EYEPLANsoftware. For patients with no local failure, the authors analyzed whether fundus photograph fusion accurately depicted and confirmed tumor volumes as outlined in the original treatment plan. For patients with local failure, the authors determined whether the addition of the fundus photograph might have benefited in terms of more accurate tumor volume delineation. Results: The mean follow-up of patients was 33.6 ± 23 months . Tumor growth was seen in six eyes of the 79 macular lesions. All six patients were marginal failures or tumor miss in the region of dose fall-off, including one patient with both in-field recurrence as well as marginal. Among the six recurrences, three were managed by enucleation and one underwent retreatment with proton therapy. Three patients developed distant metastasis and all three patients have since died. The replanning of six patients with their original fundus photograph superimposed showed that in four cases, the treatment field adequately covered the tumor volume. In the other two patients, the overlaid fundus photographs indicated the area of marginal miss. The replanning with the fundus photograph showed improved tumor coverage in these two macular lesions. For the remaining patients without local failure, replanning with fundus photograph superimposition confirmed the tumor volume as drawn in the original treatment plan. Conclusions: Local control was excellent in patients receiving 56 GyE of PBRT for uveal melanomas in the macular region, which traditionally can be more difficult to control. Posterior lesions are better defined with the additional use of fundus image since they can be difficult to mark surgically. In one-third of treatment failing patients, the superposition of the fundus photograph would have clearly allowed improved localization of tumor. The current practice standard is to use the superimposition of the fundus photograph in addition to the surgeon’s clinical and clip mapping of the tumor and ultrasound measurement to draw the tumor volume.
- 13 September 2010
- Published by Wiley in Medical Physics
- Vol. 37 (10) , 5199-5207
Fundus image fusion in EYEPLAN software: An evaluation of a novel technique for ocular melanoma radiation treatment planning
Purpose: The purpose of this study is to evaluate a novel approach for treatment planning using digital fundus image fusion inEYEPLAN for proton beam radiation therapy (PBRT) planning for ocular melanoma. The authors used a prototype version of EYEPLANsoftware, which allows for digital registration of high-resolution fundus photographs. The authors examined the improvement in tumor localization by replanning with the addition of fundus photo superimposition in patients with macular area tumors. Methods: The new version ofEYEPLAN (v3.05) software allows for the registration of fundus photographs as a background image. This is then used in conjunction with clinical examination, tantalum marker clips, surgeon’s mapping, and ultrasound to draw the tumor contour accurately. In order to determine if the fundus image superimposition helps in tumor delineation and treatment planning, the authors identified 79 patients with choroidal melanoma in the macular location that were treated with PBRT. All patients were treated to a dose of 56 GyE in four fractions. The authors reviewed and replanned all 79 macular melanoma cases with superimposition of pretreatment and post-treatment fundus imaging in the new EYEPLANsoftware. For patients with no local failure, the authors analyzed whether fundus photograph fusion accurately depicted and confirmed tumor volumes as outlined in the original treatment plan. For patients with local failure, the authors determined whether the addition of the fundus photograph might have benefited in terms of more accurate tumor volume delineation. Results: The mean follow-up of patients was 33.6 ± 23 months . Tumor growth was seen in six eyes of the 79 macular lesions. All six patients were marginal failures or tumor miss in the region of dose fall-off, including one patient with both in-field recurrence as well as marginal. Among the six recurrences, three were managed by enucleation and one underwent retreatment with proton therapy. Three patients developed distant metastasis and all three patients have since died. The replanning of six patients with their original fundus photograph superimposed showed that in four cases, the treatment field adequately covered the tumor volume. In the other two patients, the overlaid fundus photographs indicated the area of marginal miss. The replanning with the fundus photograph showed improved tumor coverage in these two macular lesions. For the remaining patients without local failure, replanning with fundus photograph superimposition confirmed the tumor volume as drawn in the original treatment plan. Conclusions: Local control was excellent in patients receiving 56 GyE of PBRT for uveal melanomas in the macular region, which traditionally can be more difficult to control. Posterior lesions are better defined with the additional use of fundus image since they can be difficult to mark surgically. In one-third of treatment failing patients, the superposition of the fundus photograph would have clearly allowed improved localization of tumor. The current practice standard is to use the superimposition of the fundus photograph in addition to the surgeon’s clinical and clip mapping of the tumor and ultrasound measurement to draw the tumor volume.
- 4 February 2009
- Published by Wiley in Medical Physics
- Vol. 36 (3) , 719-724
A noninvasive eye fixation monitoring system for CyberKnife radiotherapy of choroidal and orbital tumors
A new noninvasive monitoring system for fixing the eye has been developed to treat orbital and choroidal tumors with CyberKnife‐based radiotherapy. This device monitors the eye during CT/MRI scanning and during treatment. The results of this study demonstrate the feasibility of the fixation light system for CyberKnife‐based treatments of orbital and choroidal tumors and supports the idea that larger choroidal melanomas and choroidal metastases could be treated with CyberKnife without implanting fiducial markers.
- 4 February 2009
- Published by Wiley in Medical Physics
- Vol. 36 (3) , 719-724
A noninvasive eye fixation monitoring system for CyberKnife radiotherapy of choroidal and orbital tumors
A new noninvasive monitoring system for fixing the eye has been developed to treat orbital and choroidal tumors with CyberKnife‐based radiotherapy. This device monitors the eye during CT/MRI scanning and during treatment. The results of this study demonstrate the feasibility of the fixation light system for CyberKnife‐based treatments of orbital and choroidal tumors and supports the idea that larger choroidal melanomas and choroidal metastases could be treated with CyberKnife without implanting fiducial markers.
- 1 January 2009
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 598 (2) , 628-634
Application of flat panel digital imaging for improvement of ocular melanoma patient set-up in proton beam therapy
- 1 January 2009
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 598 (2) , 628-634
Application of flat panel digital imaging for improvement of ocular melanoma patient set-up in proton beam therapy
- 18 October 2005
- Published by Wiley in Medical Physics
- Vol. 32 (11) , 3355-3362
3D MRI‐based tumor delineation of ocular melanoma and its comparison with conventional techniques
The aim of this study is to (1) compare the delineation of the tumor volume for ocular melanoma on high‐resolution three‐dimensional (3D) T2‐weighted fast spin echo magnetic resonance imaging (MRI) images with conventional techniques of A‐ and B‐scan ultrasound, transcleral illumination, and placement of tantalum markers around tumor base and (2) to evaluate whether the surgically placed marker ring tumor delineation can be replaced by 3D MRI based tumor delineation. High‐resolution 3D T2‐weighted fast spin echo (3D FSE) MRI scans were obtained for 60 consecutive ocular melanoma patients using a 1.5 T MRI (GE Medical Systems, Milwaukee, WI), in a standard head coil. These patients were subsequently treated with proton beam therapy at the UC Davis Cyclotron, Davis, CA. The tumor was delineated by placement of tantalum rings (radio‐opaque markers) around the tumor periphery as defined by pupillary transillumination during surgery. A point light source, placed against the sclera, was also used to confirm ring agreement with indirect ophthalmoscopy. When necessary, intraoperative ultrasound was also performed. The patients were planned using EYEPLAN software and the tumor volumes were obtained. For analysis, the tumors were divided into four categories based on tumor height and basal diameter. In order to assess the impact of high‐resolution 3D T2 FSE MRI, the tumor volumes were outlined on the MRI scans by two independent observers and the tumor volumes calculated for each patient. Six (10%) of 60 patients had tumors, which were not visible on 3D MRI images. These six patients had tumors with tumor heights . A small intraobserver variation with a mean of was seen in tumor volumes delineated by 3D T2 FSE MR images. The ratio of tumor volumes measured on MRI to EYEPLAN for the largest to the smallest tumor volumes varied between 0.993 and 1.02 for 54 patients. The tumor volumes measured directly on 3D T2 FSE MRI ranged from 4.03 to with a mean of . The tumor shapes obtained from 3D T2 FSE MR images were comparable to the tumor shapes obtained using EYEPLAN software. The demonstration of intraocular tumor volumes with the high‐resolution 3D fast spin echo T2 weighted MRI is excellent and provides additional information on tumor shape. We found a high degree of accuracy for tumor volumes with direct MRI volumetric measurements in uveal melanoma patients. In some patients with extra large tumors, the tumor base and shape was modified, because of the additional information obtained from 3D T2 FSE MR images.
- 18 October 2005
- Published by Wiley in Medical Physics
- Vol. 32 (11) , 3355-3362
3D MRI‐based tumor delineation of ocular melanoma and its comparison with conventional techniques
The aim of this study is to (1) compare the delineation of the tumor volume for ocular melanoma on high‐resolution three‐dimensional (3D) T2‐weighted fast spin echo magnetic resonance imaging (MRI) images with conventional techniques of A‐ and B‐scan ultrasound, transcleral illumination, and placement of tantalum markers around tumor base and (2) to evaluate whether the surgically placed marker ring tumor delineation can be replaced by 3D MRI based tumor delineation. High‐resolution 3D T2‐weighted fast spin echo (3D FSE) MRI scans were obtained for 60 consecutive ocular melanoma patients using a 1.5 T MRI (GE Medical Systems, Milwaukee, WI), in a standard head coil. These patients were subsequently treated with proton beam therapy at the UC Davis Cyclotron, Davis, CA. The tumor was delineated by placement of tantalum rings (radio‐opaque markers) around the tumor periphery as defined by pupillary transillumination during surgery. A point light source, placed against the sclera, was also used to confirm ring agreement with indirect ophthalmoscopy. When necessary, intraoperative ultrasound was also performed. The patients were planned using EYEPLAN software and the tumor volumes were obtained. For analysis, the tumors were divided into four categories based on tumor height and basal diameter. In order to assess the impact of high‐resolution 3D T2 FSE MRI, the tumor volumes were outlined on the MRI scans by two independent observers and the tumor volumes calculated for each patient. Six (10%) of 60 patients had tumors, which were not visible on 3D MRI images. These six patients had tumors with tumor heights . A small intraobserver variation with a mean of was seen in tumor volumes delineated by 3D T2 FSE MR images. The ratio of tumor volumes measured on MRI to EYEPLAN for the largest to the smallest tumor volumes varied between 0.993 and 1.02 for 54 patients. The tumor volumes measured directly on 3D T2 FSE MRI ranged from 4.03 to with a mean of . The tumor shapes obtained from 3D T2 FSE MR images were comparable to the tumor shapes obtained using EYEPLAN software. The demonstration of intraocular tumor volumes with the high‐resolution 3D fast spin echo T2 weighted MRI is excellent and provides additional information on tumor shape. We found a high degree of accuracy for tumor volumes with direct MRI volumetric measurements in uveal melanoma patients. In some patients with extra large tumors, the tumor base and shape was modified, because of the additional information obtained from 3D T2 FSE MR images.
- 25 January 2001
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 46 (2) , 579-590
Use of high-frequency ultrasound imaging to improve delineation of anterior uveal melanoma for proton irradiation
The aim of this study was to evaluate high-frequency ultrasound imaging (HFUI) as an aid in localizing anterior margins of tumours of the eye for proton therapy. Proton irradiation of ocular melanoma requires an accurate assessment of all tumour margins. The tumour is marked surgically by suturing to the sclera four or five tantalum rings on the borders of the tumour defined by transillumination. In order to evaluate the clinical usefulness of high-frequency ultrasound imaging, four and five rings were surgically placed in a patient with an iris/ciliary body melanoma and in a patient with ciliochoroidal melanoma using transillumination to localize the tumour margins. Subsequently margins were verified by HFUI. In the first patient, the distances between the rings and the limbus were measured using calipers during surgery and were compared with HFUI measurements and measurements from planning software. The distances were comparable within 0.5 mm. In the second patient the treatment was planned in two different ways using EYEPLAN software. In the first scenario the shape of the tumour and its relation to the rings were obtained from the surgeon's mapping, the fundus drawing using a transilluminating point light source, and the HFUI. In the second scenario, the shape of the tumour was deduced from the ring positions only. It was observed that the maximum difference between the tumour edge as seen on high-frequency ultrasound images and the rings was 2.6 mm. The tumour volume was underestimated by 39% when tumour shape was obtained from ring positions only. During the past year we have utilized HFUI in 18 patients having tumours involving the anterior segment of the eye, among which four were treated with proton therapy. In conclusion, we believe that high-frequency ultrasound imaging provides additional information with respect to the location of tumour margins in ciliary body and anterior uveal melanoma. Occult extension of the tumour within the ciliary body or posterior iris may not be appreciated by transillumination alone.
- 25 January 2001
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 46 (2) , 579-590
Use of high-frequency ultrasound imaging to improve delineation of anterior uveal melanoma for proton irradiation
The aim of this study was to evaluate high-frequency ultrasound imaging (HFUI) as an aid in localizing anterior margins of tumours of the eye for proton therapy. Proton irradiation of ocular melanoma requires an accurate assessment of all tumour margins. The tumour is marked surgically by suturing to the sclera four or five tantalum rings on the borders of the tumour defined by transillumination. In order to evaluate the clinical usefulness of high-frequency ultrasound imaging, four and five rings were surgically placed in a patient with an iris/ciliary body melanoma and in a patient with ciliochoroidal melanoma using transillumination to localize the tumour margins. Subsequently margins were verified by HFUI. In the first patient, the distances between the rings and the limbus were measured using calipers during surgery and were compared with HFUI measurements and measurements from planning software. The distances were comparable within 0.5 mm. In the second patient the treatment was planned in two different ways using EYEPLAN software. In the first scenario the shape of the tumour and its relation to the rings were obtained from the surgeon's mapping, the fundus drawing using a transilluminating point light source, and the HFUI. In the second scenario, the shape of the tumour was deduced from the ring positions only. It was observed that the maximum difference between the tumour edge as seen on high-frequency ultrasound images and the rings was 2.6 mm. The tumour volume was underestimated by 39% when tumour shape was obtained from ring positions only. During the past year we have utilized HFUI in 18 patients having tumours involving the anterior segment of the eye, among which four were treated with proton therapy. In conclusion, we believe that high-frequency ultrasound imaging provides additional information with respect to the location of tumour margins in ciliary body and anterior uveal melanoma. Occult extension of the tumour within the ciliary body or posterior iris may not be appreciated by transillumination alone.