Energy Assessment of the Thermal Bridging Effects on Different Structural Envelope Types Using Mixed-Equivalent-Wall Method
Open Access
Abstract
In this paper, the effect of house envelopes including thermal bridges on the daily, monthly, and annual consumption of the air conditioning system of a detached house and an attached house, with a façade in the east, west, north, or south direction, is investigated; moreover, the capacity of the air conditioning system is calculated for detached and attached houses based on the maximum hourly peak load during severe weather conditions. The four tested house envelopes are exterior insulation and finish system (EIFS), autoclaved aerated concrete block (AAC-B), classical (cement blocks with insulation in between), and AAC column and beam (AAC-CB). The work is conducted using a method that combines the finite element method (COMSOL Multiphysics), building simulation (EnergyPlus), and the Engineering Equation Solver (EES) programs. The results indicated that the annual consumption of the air conditioning system using AAC-B, classical, and AAC-CB envelopes is larger than that of EIFS by about 3.74, 11.53, and 20.70% for the detached house, and 1.8, 2.9%, and 6.7% for the attached house, respectively. The annual consumption of the air conditioner of the detached house is larger than the average consumption of the attached house by about 25.3, 27.7, 35.8, and 41.7% for EIFS, AAC-B, classical, and AAC-CB house envelopes, respectively. Using the different façade directions of the attached house, the average effect of the house envelope type on the air conditioning system capacity is about 8.84%, with a standard deviation of 0.466%.Keywords
Funding Information
- Public Authority for Applied Education and Training (TS-21-16)
This publication has 20 references indexed in Scilit:
- Design optimization of energy efficient residential buildings in TunisiaBuilding and Environment, 2012
- Equivalent wall method for dynamic characterisation of thermal bridgesEnergy and Buildings, 2012
- Problems in the calculation of thermal bridges in dynamic conditionsEnergy and Buildings, 2011
- Contrasting the capabilities of building energy performance simulation programsBuilding and Environment, 2008
- A new approach to compute heat transfer of ground-coupled envelope in building thermal simulation softwareEnergy and Buildings, 2008
- The impact of thermal bridges on the energy demand of buildings with double brick wall constructionsEnergy and Buildings, 2008
- European residential buildings and empirical assessment of the Hellenic building stock, energy consumption, emissions and potential energy savingsBuilding and Environment, 2007
- Three-dimensional conduction z-transfer function coefficients determined from the response factorsEnergy and Buildings, 2005
- Multi-dimensional heat transfer through complex building envelope assemblies in hourly energy simulation programsEnergy and Buildings, 2002
- Equivalent Wall as a Dynamic Model of a Complex Thermal StructureJournal of Thermal Insulation and Building Envelopes, 1997