Ali Alajmi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ali Alajmi has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Hosny Abou-Ziyan
Mechanical Power Engineering Department, College of Technological Studies, PAAET, Shuwaikh 70654, Kuwait
3 shared publications - Hameed Al-Awadi
Mechanical Engineering Department, College of Technological Studies, PAAET, Kuwait City 70554, Kuwait
2 shared publications David Sailor
1 shared publicationEman AbouZiyan
Ain Shams University
1 shared publicationHosny Abou-Ziyan
College of Technological Studies, PAAET
1 shared publicationJonathan Wright
Department of Civil and Building Engineering, Loughborough University, Loughborough, Leicestershire LE11 3TU, UK
1 shared publication
Latest Publications
- 30 January 2026
- Published by Springer Nature
- p. 303-316
Inverse Uncertainty Analysis to Predict Indeterministic Building Design Parameters Based on Detailed Energy Measurements in Hot Climates
- 30 January 2026
- Published by Springer Nature
- p. 303-316
Inverse Uncertainty Analysis to Predict Indeterministic Building Design Parameters Based on Detailed Energy Measurements in Hot Climates
- Open Access
- 8 September 2025
- Published by Elsevier in Energy Reports
- Vol. 14, 2204-2216
Quantifying energy use intensity and peak demand in a hot-arid residential building: Insights from four years of high-resolution monitoring
- 8 September 2025
- Published by Elsevier in Energy Reports
- Vol. 14, 2204-2216
Open AccessQuantifying energy use intensity and peak demand in a hot-arid residential building: Insights from four years of high-resolution monitoring
- Open Access
- 24 October 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 53 (1) , 27
Retrofitting Strategy of Residential Buildings Based on Detailed Energy Monitoring Measurements in Hot Climate
In this comprehensive study, a typical house underwent extensive monitoring over several years to measure direct deterministic consumption of each active system component. The indeterministic components including infiltration, air conditioner, fenestration and envelope performances were found through inverse sensitivity analysis. The data collected over the monitoring period revealed that the Energy Use Intensity (EUI) of the house amounted to 184 kWh/m2/year, for which the air-conditioning system accounted for approximately 80%. To reduce this demand, it is imperative to enhance the air tightness and thermal characteristics of the fenestration and envelope of the building. In addition, the air conditioner with higher performance must be promoted.
- 24 October 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 53 (1) , 27
Open AccessRetrofitting Strategy of Residential Buildings Based on Detailed Energy Monitoring Measurements in Hot Climate
In this comprehensive study, a typical house underwent extensive monitoring over several years to measure direct deterministic consumption of each active system component. The indeterministic components including infiltration, air conditioner, fenestration and envelope performances were found through inverse sensitivity analysis. The data collected over the monitoring period revealed that the Energy Use Intensity (EUI) of the house amounted to 184 kWh/m2/year, for which the air-conditioning system accounted for approximately 80%. To reduce this demand, it is imperative to enhance the air tightness and thermal characteristics of the fenestration and envelope of the building. In addition, the air conditioner with higher performance must be promoted.
- Open Access
Energy Assessment of the Thermal Bridging Effects on Different Structural Envelope Types Using Mixed-Equivalent-Wall Method
In this paper, the effect of house envelopes including thermal bridges on the daily, monthly, and annual consumption of the air conditioning system of a detached house and an attached house, with a façade in the east, west, north, or south direction, is investigated; moreover, the capacity of the air conditioning system is calculated for detached and attached houses based on the maximum hourly peak load during severe weather conditions. The four tested house envelopes are exterior insulation and finish system (EIFS), autoclaved aerated concrete block (AAC-B), classical (cement blocks with insulation in between), and AAC column and beam (AAC-CB). The work is conducted using a method that combines the finite element method (COMSOL Multiphysics), building simulation (EnergyPlus), and the Engineering Equation Solver (EES) programs. The results indicated that the annual consumption of the air conditioning system using AAC-B, classical, and AAC-CB envelopes is larger than that of EIFS by about 3.74, 11.53, and 20.70% for the detached house, and 1.8, 2.9%, and 6.7% for the attached house, respectively. The annual consumption of the air conditioner of the detached house is larger than the average consumption of the attached house by about 25.3, 27.7, 35.8, and 41.7% for EIFS, AAC-B, classical, and AAC-CB house envelopes, respectively. Using the different façade directions of the attached house, the average effect of the house envelope type on the air conditioning system capacity is about 8.84%, with a standard deviation of 0.466%.
Open AccessEnergy Assessment of the Thermal Bridging Effects on Different Structural Envelope Types Using Mixed-Equivalent-Wall Method
In this paper, the effect of house envelopes including thermal bridges on the daily, monthly, and annual consumption of the air conditioning system of a detached house and an attached house, with a façade in the east, west, north, or south direction, is investigated; moreover, the capacity of the air conditioning system is calculated for detached and attached houses based on the maximum hourly peak load during severe weather conditions. The four tested house envelopes are exterior insulation and finish system (EIFS), autoclaved aerated concrete block (AAC-B), classical (cement blocks with insulation in between), and AAC column and beam (AAC-CB). The work is conducted using a method that combines the finite element method (COMSOL Multiphysics), building simulation (EnergyPlus), and the Engineering Equation Solver (EES) programs. The results indicated that the annual consumption of the air conditioning system using AAC-B, classical, and AAC-CB envelopes is larger than that of EIFS by about 3.74, 11.53, and 20.70% for the detached house, and 1.8, 2.9%, and 6.7% for the attached house, respectively. The annual consumption of the air conditioner of the detached house is larger than the average consumption of the attached house by about 25.3, 27.7, 35.8, and 41.7% for EIFS, AAC-B, classical, and AAC-CB house envelopes, respectively. Using the different façade directions of the attached house, the average effect of the house envelope type on the air conditioning system capacity is about 8.84%, with a standard deviation of 0.466%.
- Open Access
Effect of Thermal Bridges of Different External Wall Types on the Thermal Performance of Residential Building Envelope in a Hot Climate
In this paper, the thermal performance of residential building envelopes including thermal bridges (TBs) in a hot climate, using four different exterior wall types, is modelled and assessed. TBs at the junctions between columns and walls and between walls and slabs of the ground floor, roof, and intermediate floors are considered. The tested wall types are classical (two layers of cement blocks with insulation in between), autoclaved aerated concrete bearing (AAC-B), AAC column and beam (AAC-CB), and exterior insulation and finish system (EIFS). The results indicated that thermal bridges have a considerable effect and determine the best external wall type which was the EIFS that has a continuous exterior insulation. EIFS proved to reduce the heat transmission with the outdoor environment for residential buildings by 101.8, 51.2, and 13.9% than the AAC-CB, AAC-B, and classical walls, respectively. Thermal bridges effect on the building envelope using the EIFS is insignificant as the thermal resistance of the envelope and wall differs by less than 1% for small areas. The overall heat transfer coefficients for small buildings are larger than those for large buildings by 8–26%. As the number of intermediate floors increases from 1 to 50, the envelope overall heat transfer coefficient increases by 4.5% for the EIFS, 14.1% for classical, and 19.5% for AAC-CB walls. The AAC-CB, as the common practice wall structure in many hot climate countries, has the lowest performance among the tested wall types.
Open AccessEffect of Thermal Bridges of Different External Wall Types on the Thermal Performance of Residential Building Envelope in a Hot Climate
In this paper, the thermal performance of residential building envelopes including thermal bridges (TBs) in a hot climate, using four different exterior wall types, is modelled and assessed. TBs at the junctions between columns and walls and between walls and slabs of the ground floor, roof, and intermediate floors are considered. The tested wall types are classical (two layers of cement blocks with insulation in between), autoclaved aerated concrete bearing (AAC-B), AAC column and beam (AAC-CB), and exterior insulation and finish system (EIFS). The results indicated that thermal bridges have a considerable effect and determine the best external wall type which was the EIFS that has a continuous exterior insulation. EIFS proved to reduce the heat transmission with the outdoor environment for residential buildings by 101.8, 51.2, and 13.9% than the AAC-CB, AAC-B, and classical walls, respectively. Thermal bridges effect on the building envelope using the EIFS is insignificant as the thermal resistance of the envelope and wall differs by less than 1% for small areas. The overall heat transfer coefficients for small buildings are larger than those for large buildings by 8–26%. As the number of intermediate floors increases from 1 to 50, the envelope overall heat transfer coefficient increases by 4.5% for the EIFS, 14.1% for classical, and 19.5% for AAC-CB walls. The AAC-CB, as the common practice wall structure in many hot climate countries, has the lowest performance among the tested wall types.
- 20 June 2021
- Published by Taylor & Francis in International Journal of Sustainable Engineering
- Vol. 14 (4) , 630-646
Implementing the Integrated Design Process (IDP) to design, construct and monitor an eco-house in hot climate
Eco-houses play a pivotal role in reducing greenhouse gas emissions. To implement such a concept, the current Conventional Design Process (CDP) needs to be improved. Thus, Integrated Design Process (IDP) was recently introduced to the buildings sector. IDP involves early stakeholders in a systematic approach to achieve performance targets. In this study, IDP was implemented in a single-family house, targeting efficient houses with minimum/no cost. Many energy efficiency strategies (EESs), such as envelop insulation, orientation, window properties, and efficient air-conditioning system, have been applied. These energy strategies predicted a substantial energy reduction where the energy use intensity (EUI) would fall from 182 to 72 kWh/m2.year. In addition, solar renewable energy, domestic solar hot water (DSHW), and photovoltaic (PV) panels (10 kW) saved 18.78 MWh/year. Besides, water efficiency strategies (WESs) are anticipated to save 217,581 gallons/year due to the use of a water recycling unit, low flowrate faucets, and efficient shower systems, all of which have been proposed. All the recommended energy efficiency strategies (EESs) and water efficiency strategies (WESs) had a simple payback period of fewer than 10 years and proved their cost feasibility over their life-cycle. Moreover, a considerable CO₂ emission avoidance (117 tons/year) was attained.
- 20 June 2021
- Published by Taylor & Francis in International Journal of Sustainable Engineering
- Vol. 14 (4) , 630-646
Implementing the Integrated Design Process (IDP) to design, construct and monitor an eco-house in hot climate
Eco-houses play a pivotal role in reducing greenhouse gas emissions. To implement such a concept, the current Conventional Design Process (CDP) needs to be improved. Thus, Integrated Design Process (IDP) was recently introduced to the buildings sector. IDP involves early stakeholders in a systematic approach to achieve performance targets. In this study, IDP was implemented in a single-family house, targeting efficient houses with minimum/no cost. Many energy efficiency strategies (EESs), such as envelop insulation, orientation, window properties, and efficient air-conditioning system, have been applied. These energy strategies predicted a substantial energy reduction where the energy use intensity (EUI) would fall from 182 to 72 kWh/m2.year. In addition, solar renewable energy, domestic solar hot water (DSHW), and photovoltaic (PV) panels (10 kW) saved 18.78 MWh/year. Besides, water efficiency strategies (WESs) are anticipated to save 217,581 gallons/year due to the use of a water recycling unit, low flowrate faucets, and efficient shower systems, all of which have been proposed. All the recommended energy efficiency strategies (EESs) and water efficiency strategies (WESs) had a simple payback period of fewer than 10 years and proved their cost feasibility over their life-cycle. Moreover, a considerable CO₂ emission avoidance (117 tons/year) was attained.
- 1 September 2018
- Published by Elsevier in Energy Conversion and Management
- Vol. 172, 39-49
Transforming a passive house into a net-zero energy house: a case study in the Pacific Northwest of the U.S.
- 1 September 2018
- Published by Elsevier in Energy Conversion and Management
- Vol. 172, 39-49
Transforming a passive house into a net-zero energy house: a case study in the Pacific Northwest of the U.S.
- Open Access
- 1 June 2016
- Published by Elsevier in International Journal of Sustainable Built Environment
- Vol. 5 (1) , 123-131
Efficient Genetic Algorithm sets for optimizing constrained building design problem
- 1 June 2016
- Published by Elsevier in International Journal of Sustainable Built Environment
- Vol. 5 (1) , 123-131
Open AccessEfficient Genetic Algorithm sets for optimizing constrained building design problem