The development and validation of an easy to use automatic QT-interval algorithm
Open Access
- 1 September 2017
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (9) , e0184352
Abstract
To evaluate QT-interval dynamics in patients and in drug safety analysis, beat-to-beat QT-interval measurements are increasingly used. However, interobserver differences, aberrant T-wave morphologies and changes in heart axis might hamper accurate QT-interval measurements. To develop and validate a QT-interval algorithm robust to heart axis orientation and T-wave morphology that can be applied on a beat-to-beat basis. Additionally to standard ECG leads, the root mean square (ECGRMS), standard deviation and vectorcardiogram were used. QRS-onset was defined from the ECGRMS. T-wave end was defined per individual lead and scalar ECG using an automated tangent method. A median of all T-wave ends was used as the general T-wave end per beat. Supine-standing tests of 73 patients with Long-QT syndrome (LQTS) and 54 controls were used because they have wide ranges of RR and QT-intervals as well as changes in T-wave morphology and heart axis orientation. For each subject, automatically estimated QT-intervals in three random complexes chosen from the low, middle and high RR range, were compared with manually measured QT-intervals by three observers. After visual inspection of the randomly selected complexes, 21 complexes were excluded because of evident noise, too flat T-waves or premature ventricular beats. Bland-Altman analyses of automatically and manually determined QT-intervals showed a bias of 0.9) between the algorithm and all observers individually as well as between the algorithm and the mean QT-interval of the observers. Our automated algorithm provides reliable beat-to-beat QT-interval assessment, robust to heart axis and T-wave morphology.Keywords
This publication has 28 references indexed in Scilit:
- Conventional QT Variability Measurement vs. Template Matching Techniques: Comparison of Performance Using Simulated and Real ECGPLOS ONE, 2012
- The phenomenon of “QT stunning”: The abnormal QT prolongation provoked by standing persists even as the heart rate returns to normal in patients with long QT syndromeHeart Rhythm, 2012
- The Response of the QT Interval to the Brief Tachycardia Provoked by StandingJACC, 2010
- The QT interval: Too long, too short or just rightHeart Rhythm, 2009
- Diagnostic Miscues in Congenital Long-QT SyndromeCirculation, 2007
- Inaccurate electrocardiographic interpretation of long QT: The majority of physicians cannot recognize a long QT when they see oneHeart Rhythm, 2005
- Electrophysiological basis of QT dispersion measurementsProgress in Cardiovascular Diseases, 2000
- Forming inferences about some intraclass correlation coefficients.Psychological Methods, 1996
- QT dispersion: an indication of arrhythmia risk in patients with long QT intervals.Heart, 1990
- The Measurement of the Q-T Interval of the ElectrocardiogramCirculation, 1952