Veronique M. F. Meijborg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Veronique M. F. Meijborg has a total of 163 co-authors. Here are the top co-authors by number of shared publications:
- Ruben Coronel
Departments of Clinical and Experimental Cardiology, Heart Center Amsterdam UMC, location University of Amsterdam Amsterdam the Netherlands
16 shared publications - Bastiaan J. Boukens
Laboratory of Experimental Cardiology, Department of Cardiology, LUMC, Leiden, The Netherlands
7 shared publications - Benjamin Kappler
LifeTec Group B.V, 10-11, Kennedyplein, Eindhoven 5611 ZS, The Netherlands; Department of Cardiothoracic Surgery, University Medical Center of Amsterdam, AMC Heart Center, Amsterdam 1105 AZ, The Netherlands
4 shared publications - Marco Stijnen
LifeTec Group, Eindhoven, The Netherlands
4 shared publications - P. J. Tan
University College London
4 shared publications Carlos Ledezma
3 shared publications
Latest Publications
- Open Access
- 9 January 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (2)
Computer-aided characterization of the arrhythmogenic substrate after myocardial infarction
Ventricular tachycardia (VT) and ventricular fibrillation remain major contributors to sudden cardiac death, with current therapies limited by our incomplete understanding of the arrhythmogenic substrate. This narrative review explores recent developments in computer-aided techniques for characterizing the arrhythmogenic substrate, focusing on post-myocardial infarction VT. High-resolution cardiac imaging now enables detailed visualization of structural abnormalities, including heterogeneous scar architecture and fatty infiltration. Sophisticated invasive mapping techniques provide insights into local electrophysiological properties, while novel non-invasive mapping approaches offer complementary views of global electrical patterns. Integration of these modalities through computational simulations allows for mechanistic insights into arrhythmia initiation and maintenance, particularly in post-myocardial infarction VT, where structural and functional substrates interact in complex ways. Emerging artificial intelligence applications enhance substrate analysis through automated feature extraction and pattern recognition, enabling more sophisticated risk stratification. These computer-aided approaches are advancing from research tools to clinical applications, with early evidence suggesting improved ablation outcomes and better risk prediction. However, significant challenges remain in validation, standardization, and clinical implementation of these innovations. This narrative review highlights recent methodological advances and clinical applications of computer-aided substrate characterization, and conceptualizes future directions towards personalized arrhythmia management, also beyond post-infarction VTs.
- 9 January 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (2)
Open AccessComputer-aided characterization of the arrhythmogenic substrate after myocardial infarction
Ventricular tachycardia (VT) and ventricular fibrillation remain major contributors to sudden cardiac death, with current therapies limited by our incomplete understanding of the arrhythmogenic substrate. This narrative review explores recent developments in computer-aided techniques for characterizing the arrhythmogenic substrate, focusing on post-myocardial infarction VT. High-resolution cardiac imaging now enables detailed visualization of structural abnormalities, including heterogeneous scar architecture and fatty infiltration. Sophisticated invasive mapping techniques provide insights into local electrophysiological properties, while novel non-invasive mapping approaches offer complementary views of global electrical patterns. Integration of these modalities through computational simulations allows for mechanistic insights into arrhythmia initiation and maintenance, particularly in post-myocardial infarction VT, where structural and functional substrates interact in complex ways. Emerging artificial intelligence applications enhance substrate analysis through automated feature extraction and pattern recognition, enabling more sophisticated risk stratification. These computer-aided approaches are advancing from research tools to clinical applications, with early evidence suggesting improved ablation outcomes and better risk prediction. However, significant challenges remain in validation, standardization, and clinical implementation of these innovations. This narrative review highlights recent methodological advances and clinical applications of computer-aided substrate characterization, and conceptualizes future directions towards personalized arrhythmia management, also beyond post-infarction VTs.
- Open Access
AAV6-HCN4t-mediated biological pacing as a potential life-saving therapy for congenital complete heart block
Congenital complete heart block (CCHB) is a life-threatening condition in fetuses due to severe bradycardia. Maternal administration of β-adrenergic agonists is used to increase fetal heart rates, but its effectiveness is limited and lost over time most likely due to insufficient expression of HCN channels in some individuals. We report the development of an injectable gene therapy that produces reliable cardiac pacemaker function in the presence of β-adrenergic stimulation. Intramyocardial injection of adeno-associated viral serotype 6 vectors expressing HCN4t (AAV6-HCN4t) into the left ventricular apex significantly increased ectopic pacing frequency and heart rate in response to isoproterenol in rats with complete heart block, and this effect remained stable throughout the 4 weeks of follow-up. Injection of AAV6-HCN4t showed similar reliable biological pacing in complete heart block pigs. These results suggest that AAV6-HCN4t generates robust biological pacing in the presence of isoproterenol, providing the foundation for a potentially life-saving therapy for in utero CCHB.
Open AccessAAV6-HCN4t-mediated biological pacing as a potential life-saving therapy for congenital complete heart block
Congenital complete heart block (CCHB) is a life-threatening condition in fetuses due to severe bradycardia. Maternal administration of β-adrenergic agonists is used to increase fetal heart rates, but its effectiveness is limited and lost over time most likely due to insufficient expression of HCN channels in some individuals. We report the development of an injectable gene therapy that produces reliable cardiac pacemaker function in the presence of β-adrenergic stimulation. Intramyocardial injection of adeno-associated viral serotype 6 vectors expressing HCN4t (AAV6-HCN4t) into the left ventricular apex significantly increased ectopic pacing frequency and heart rate in response to isoproterenol in rats with complete heart block, and this effect remained stable throughout the 4 weeks of follow-up. Injection of AAV6-HCN4t showed similar reliable biological pacing in complete heart block pigs. These results suggest that AAV6-HCN4t generates robust biological pacing in the presence of isoproterenol, providing the foundation for a potentially life-saving therapy for in utero CCHB.
- Open Access
- 14 July 2025
- Published by Oxford University Press (OUP) in Cardiovascular Research
- Vol. 121 (9) , 1385-1391
Right stellate ganglion stimulation modulates arrhythmogenesis in acute left lateral ventricular ischaemia
Aims: Acute myocardial ischaemia causes fatal arrhythmias as result of a flow of ‘injury current’. Left stellate ganglion stimulation (LSGS) modulates the injury current and is arrhythmogenic during left anterior ventricular wall ischaemia. The role of right stellate ganglion stimulation (RSGS) in arrhythmogenesis is unclear. We hypothesized that RSGS is proarrhythmic during left lateral ventricular wall ischaemia. Methods and results: In 11 anaesthetized female pigs, ventricular repolarization was measured in unipolar epicardial electrograms from the left lateral ventricular wall. Seven subsequent episodes of acute ischaemia (5 min) were produced by occlusion of the circumflex coronary artery (CX), separated by 20 min of reperfusion. The second occlusion served as a control. After 3 min of ischaemia during the third occlusion, LSGS was initiated for 30 s. In the 4th occlusion, RSGS was performed. After decentralization of both left and right stellate ganglia and vagal nerves, LSGS and RSGS were initiated (6th and 7th occlusions). RSGS during ischaemia was more arrhythmogenic than LSGS or control with more spontaneous ventricular premature beats (3–5 min of ischaemia) and two instances of ventricular fibrillation. The LSGS-induced effect on repolarization was absent in myocardium that had been ischaemic for 3 min by CX occlusion. Conclusions: LSGS-induced repolarization shortening is absent in ischaemic myocardium. RSGS was more arrhythmogenic following CX occlusion than LSGS or control. These data demonstrate that the arrhythmogenic influence of RSGS or LSGS is contingent on the location of ischaemic zone supporting the clinical findings that bilateral sympathectomy is superior to left sympathectomy alone.
- 14 July 2025
- Published by Oxford University Press (OUP) in Cardiovascular Research
- Vol. 121 (9) , 1385-1391
Open AccessRight stellate ganglion stimulation modulates arrhythmogenesis in acute left lateral ventricular ischaemia
Aims: Acute myocardial ischaemia causes fatal arrhythmias as result of a flow of ‘injury current’. Left stellate ganglion stimulation (LSGS) modulates the injury current and is arrhythmogenic during left anterior ventricular wall ischaemia. The role of right stellate ganglion stimulation (RSGS) in arrhythmogenesis is unclear. We hypothesized that RSGS is proarrhythmic during left lateral ventricular wall ischaemia. Methods and results: In 11 anaesthetized female pigs, ventricular repolarization was measured in unipolar epicardial electrograms from the left lateral ventricular wall. Seven subsequent episodes of acute ischaemia (5 min) were produced by occlusion of the circumflex coronary artery (CX), separated by 20 min of reperfusion. The second occlusion served as a control. After 3 min of ischaemia during the third occlusion, LSGS was initiated for 30 s. In the 4th occlusion, RSGS was performed. After decentralization of both left and right stellate ganglia and vagal nerves, LSGS and RSGS were initiated (6th and 7th occlusions). RSGS during ischaemia was more arrhythmogenic than LSGS or control with more spontaneous ventricular premature beats (3–5 min of ischaemia) and two instances of ventricular fibrillation. The LSGS-induced effect on repolarization was absent in myocardium that had been ischaemic for 3 min by CX occlusion. Conclusions: LSGS-induced repolarization shortening is absent in ischaemic myocardium. RSGS was more arrhythmogenic following CX occlusion than LSGS or control. These data demonstrate that the arrhythmogenic influence of RSGS or LSGS is contingent on the location of ischaemic zone supporting the clinical findings that bilateral sympathectomy is superior to left sympathectomy alone.
- Open Access
- 18 July 2023
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 12 (14) , e026419
Diagnostic Accuracy of the Standing Test in Adults Suspected for Congenital Long‐QT Syndrome
Background: An elegant bedside provocation test has been shown to aid the diagnosis of long‐QT syndrome (LQTS) in a retrospective cohort by evaluation of QT intervals and T‐wave morphology changes resulting from the brief tachycardia provoked by standing. We aimed to prospectively determine the potential diagnostic value of the standing test for LQTS. Methods and Results: In adults suspected for LQTS who had a standing test, the QT interval was assessed manually and automated. In addition, T‐wave morphology changes were determined. A total of 167 controls and 131 genetically confirmed patients with LQTS were included. A prolonged heart rate–corrected QT interval (QTc) (men ≥430 ms, women ≥450 ms) at baseline before standing yielded a sensitivity of 61% (95% CI, 47–74) in men and 54% (95% CI, 42–66) in women, with a specificity of 90% (95% CI, 80–96) and 89% (95% CI, 81–95), respectively. In both men and women, QTc≥460 ms after standing increased sensitivity (89% [95% CI, 83–94]) but decreased specificity (49% [95% CI, 41–57]). Sensitivity further increased ( P <0.01) when a prolonged baseline QTc was accompanied by a QTc≥460 ms after standing in both men (93% [95% CI, 84–98]) and women (90% [95% CI, 81–96]). However, the area under the curve did not improve. T‐wave abnormalities after standing did not further increase the sensitivity or the area under the curve significantly. Conclusions: Despite earlier retrospective studies, a baseline ECG and the standing test in a prospective evaluation displayed a different diagnostic profile for congenital LQTS but no unequivocal synergism or advantage. This suggests that there is markedly reduced penetrance and incomplete expression in genetically confirmed LQTS with retention of repolarization reserve in response to the brief tachycardia provoked by standing.
- 18 July 2023
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 12 (14) , e026419
Open AccessDiagnostic Accuracy of the Standing Test in Adults Suspected for Congenital Long‐QT Syndrome
Background: An elegant bedside provocation test has been shown to aid the diagnosis of long‐QT syndrome (LQTS) in a retrospective cohort by evaluation of QT intervals and T‐wave morphology changes resulting from the brief tachycardia provoked by standing. We aimed to prospectively determine the potential diagnostic value of the standing test for LQTS. Methods and Results: In adults suspected for LQTS who had a standing test, the QT interval was assessed manually and automated. In addition, T‐wave morphology changes were determined. A total of 167 controls and 131 genetically confirmed patients with LQTS were included. A prolonged heart rate–corrected QT interval (QTc) (men ≥430 ms, women ≥450 ms) at baseline before standing yielded a sensitivity of 61% (95% CI, 47–74) in men and 54% (95% CI, 42–66) in women, with a specificity of 90% (95% CI, 80–96) and 89% (95% CI, 81–95), respectively. In both men and women, QTc≥460 ms after standing increased sensitivity (89% [95% CI, 83–94]) but decreased specificity (49% [95% CI, 41–57]). Sensitivity further increased ( P <0.01) when a prolonged baseline QTc was accompanied by a QTc≥460 ms after standing in both men (93% [95% CI, 84–98]) and women (90% [95% CI, 81–96]). However, the area under the curve did not improve. T‐wave abnormalities after standing did not further increase the sensitivity or the area under the curve significantly. Conclusions: Despite earlier retrospective studies, a baseline ECG and the standing test in a prospective evaluation displayed a different diagnostic profile for congenital LQTS but no unequivocal synergism or advantage. This suggests that there is markedly reduced penetrance and incomplete expression in genetically confirmed LQTS with retention of repolarization reserve in response to the brief tachycardia provoked by standing.
- Open Access
- 19 August 2022
- Published by Wiley in Annals of Noninvasive Electrocardiology
- Vol. 27 (6) , e12994
Steep repolarization time gradients in pig hearts cause distinct changes in composite electrocardiographic T‐wave parameters
Background: The T wave of the electrocardiogram (ECG) reflects ventricular repolarization. Repolarization heterogeneity is associated with reentrant arrhythmias. Several T‐wave markers (including QT interval) have been associated with ventricular arrhythmias, but studies linking such markers to underlying local repolarization time (RT) inhomogeneities are lacking. We aimed to investigate the relation of several T‐wave markers to controlled drug‐induced regional RT gradients in intact pig hearts.Methods: Repolarization time gradients were created by regional infusion of dofetilide and pinacidil in four atrially paced porcine Langendorff‐perfused hearts placed inside a torso tank. From the 12‐lead ECG on the torso tank, the mean, maximum, and dispersion (max–min) of QTtime, JTtime, Tpeak–end, Twidth, TQratio, dV/dtmax, Tarea, Tamp, and T‐upslope duration were determined, as well as upslope end difference between leads V1 and V6.Results: Temporal T‐wave parameters Tpeak–end, Twidth, and TQratio show a significant and high correlation with RT gradient, best reflected by mean value. Tarea (mean, max and dispersion) and dV/dtmax dispersion show only a moderate significant correlation. T‐upslope duration shows a significant correlation in particular for mean values. Mean, maximum, or dispersion of QTtime and V1–V6 upslope end difference were not significantly correlated with RT gradient.Conclusion: Composite 12‐lead ECG T‐wave parameters Tpeak–end, Twidth, TQratio, upslope duration, and Tarea show a good correlation with underlying RT heterogeneity, whereas standard clinical metrics such as QTtime do not reflect local RT heterogeneity. The composite T‐wave metrics may thus provide better insights in arrhythmia susceptibility than traditional QTtime metrics.
- 19 August 2022
- Published by Wiley in Annals of Noninvasive Electrocardiology
- Vol. 27 (6) , e12994
Open AccessSteep repolarization time gradients in pig hearts cause distinct changes in composite electrocardiographic T‐wave parameters
Background: The T wave of the electrocardiogram (ECG) reflects ventricular repolarization. Repolarization heterogeneity is associated with reentrant arrhythmias. Several T‐wave markers (including QT interval) have been associated with ventricular arrhythmias, but studies linking such markers to underlying local repolarization time (RT) inhomogeneities are lacking. We aimed to investigate the relation of several T‐wave markers to controlled drug‐induced regional RT gradients in intact pig hearts.Methods: Repolarization time gradients were created by regional infusion of dofetilide and pinacidil in four atrially paced porcine Langendorff‐perfused hearts placed inside a torso tank. From the 12‐lead ECG on the torso tank, the mean, maximum, and dispersion (max–min) of QTtime, JTtime, Tpeak–end, Twidth, TQratio, dV/dtmax, Tarea, Tamp, and T‐upslope duration were determined, as well as upslope end difference between leads V1 and V6.Results: Temporal T‐wave parameters Tpeak–end, Twidth, and TQratio show a significant and high correlation with RT gradient, best reflected by mean value. Tarea (mean, max and dispersion) and dV/dtmax dispersion show only a moderate significant correlation. T‐upslope duration shows a significant correlation in particular for mean values. Mean, maximum, or dispersion of QTtime and V1–V6 upslope end difference were not significantly correlated with RT gradient.Conclusion: Composite 12‐lead ECG T‐wave parameters Tpeak–end, Twidth, TQratio, upslope duration, and Tarea show a good correlation with underlying RT heterogeneity, whereas standard clinical metrics such as QTtime do not reflect local RT heterogeneity. The composite T‐wave metrics may thus provide better insights in arrhythmia susceptibility than traditional QTtime metrics.
- 28 April 2022
- Published by Elsevier in Heart Rhythm
- Vol. 19 (5) , S168-S169
PO-631-03 DEEP LEARNING FOR THE IDENTIFICATION OF PATIENTS WITH A HIGH RISK FOR IDIOPATHIC VENTRICULAR FIBRILLATION
- 28 April 2022
- Published by Elsevier in Heart Rhythm
- Vol. 19 (5) , S168-S169
PO-631-03 DEEP LEARNING FOR THE IDENTIFICATION OF PATIENTS WITH A HIGH RISK FOR IDIOPATHIC VENTRICULAR FIBRILLATION
- Open Access
- 22 October 2021
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 12
Ex vivo Validation of Noninvasive Epicardial and Endocardial Repolarization Mapping
Background: The detection and localization of electrophysiological substrates currently involve invasive cardiac mapping. Electrocardiographic imaging (ECGI) using the equivalent dipole layer (EDL) method allows the noninvasive estimation of endocardial and epicardial activation and repolarization times (AT and RT), but the RT validation is limited to in silico studies. We aimed to assess the temporal and spatial accuracy of the EDL method in reconstructing the RTs from the surface ECG under physiological circumstances and situations with artificially induced increased repolarization heterogeneity.Methods: In four Langendorff-perfused pig hearts, we simultaneously recorded unipolar electrograms from plunge needles and pseudo-ECGs from a volume-conducting container equipped with 61 electrodes. The RTs were computed from the ECGs during atrial and ventricular pacing and compared with those measured from the local unipolar electrograms. Regional RT prolongation (cooling) or shortening (pinacidil) was achieved by selective perfusion of the left anterior descending artery (LAD) region.Results: The differences between the computed and measured RTs were 19.0 ± 17.8 and 18.6 ± 13.7 ms for atrial and ventricular paced beats, respectively. The region of artificially delayed or shortened repolarization was correctly identified, with minimum/maximum RT roughly in the center of the region in three hearts. In one heart, the reconstructed region was shifted by ~2.5 cm. The total absolute difference between the measured and calculated RTs for all analyzed patterns in selectively perfused hearts (n = 5) was 39.6 ± 27.1 ms.Conclusion: The noninvasive ECG repolarization imaging using the EDL method of atrial and ventricular paced beats allows adequate quantitative reconstruction of regions of altered repolarization.
- 22 October 2021
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 12
Open AccessEx vivo Validation of Noninvasive Epicardial and Endocardial Repolarization Mapping
Background: The detection and localization of electrophysiological substrates currently involve invasive cardiac mapping. Electrocardiographic imaging (ECGI) using the equivalent dipole layer (EDL) method allows the noninvasive estimation of endocardial and epicardial activation and repolarization times (AT and RT), but the RT validation is limited to in silico studies. We aimed to assess the temporal and spatial accuracy of the EDL method in reconstructing the RTs from the surface ECG under physiological circumstances and situations with artificially induced increased repolarization heterogeneity.Methods: In four Langendorff-perfused pig hearts, we simultaneously recorded unipolar electrograms from plunge needles and pseudo-ECGs from a volume-conducting container equipped with 61 electrodes. The RTs were computed from the ECGs during atrial and ventricular pacing and compared with those measured from the local unipolar electrograms. Regional RT prolongation (cooling) or shortening (pinacidil) was achieved by selective perfusion of the left anterior descending artery (LAD) region.Results: The differences between the computed and measured RTs were 19.0 ± 17.8 and 18.6 ± 13.7 ms for atrial and ventricular paced beats, respectively. The region of artificially delayed or shortened repolarization was correctly identified, with minimum/maximum RT roughly in the center of the region in three hearts. In one heart, the reconstructed region was shifted by ~2.5 cm. The total absolute difference between the measured and calculated RTs for all analyzed patterns in selectively perfused hearts (n = 5) was 39.6 ± 27.1 ms.Conclusion: The noninvasive ECG repolarization imaging using the EDL method of atrial and ventricular paced beats allows adequate quantitative reconstruction of regions of altered repolarization.
- 1 September 2021
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 321 (3) , H569-H576
Interplay between temporal and spatial dispersion of repolarization in the initiation and perpetuation of torsades de pointes in the chronic atrioventricular block dog
Ventricular arrhythmias, consisting of single ectopic beats (sEB), multiple EB (mEB), and torsades de pointes (TdP, defined as ≥5 beats with QRS vector twisting around isoelectric line) can be induced in the anesthetized chronic atrioventricular block (CAVB) dog by dofetilide (IKr blocker). The interplay between temporal dispersion of repolarization, quantified as short-term variability (STV), and spatial dispersion of repolarization (SDR) in the initiation and perpetuation of these arrhythmias remains unclear. Five inducible (≥3 TdPs/10 min) CAVB dogs underwent one mapping experiment and were observed for 10 min from the start of dofetilide infusion (0.025 mg/kg, 5 min). An intracardiac decapolar electrogram (EGM) catheter and 30 intramural cardiac needles in the left ventricle (LV) were introduced. STVARI was derived from 31 consecutive activation recovery intervals (ARIs) on the intracardiac EGM, using the formula: . The mean SDR3D in the LV was determined as the three-dimensional repolarization time differences between the intramural cardiac needles. Moments of measurement included baseline (BL) and after dofetilide infusion before first 1) sEB (occurrence at 100 ± 35 s), 2) mEB (224 ± 96 s), and 3) non-self-terminating TdP (454 ± 298 s). STVARI increased from 2.15 ± 0.32 ms at BL to 3.73 ± 0.99 ms* before the first sEB and remained increased without further significant progression to mEB (4.41 ± 0.45 ms*) and TdP (5.07 ± 0.84 ms*) (*P < 0.05 compared with BL). SDR3D did not change from 31 ± 11 ms at BL to 43 ± 13 ms before sEB but increased significantly before mEB (68 ± 7 ms*) and to TdP (86 ± 9 ms*+) (+P < 0.05 compared with sEB). An increase in STV contributes to the initiation of sEB, whereas an increase in SDR is important for the perpetuation of non-self-terminating TdPs. NEW & NOTEWORTHY This study compared two well-established electrophysiological parameters, being temporal and spatial dispersion of repolarization, and provided new insights into their interplay in the arrhythmogenesis of torsades de pointes arrhythmias. Although it confirmed that an increase in temporal dispersion of repolarization contributes to the initiation of single ectopic beats, it showed that an increase in spatial dispersion of repolarization is important for the perpetuation of non-self-terminating torsades de pointes arrhythmias.- 1 September 2021
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 321 (3) , H569-H576
Interplay between temporal and spatial dispersion of repolarization in the initiation and perpetuation of torsades de pointes in the chronic atrioventricular block dog
Ventricular arrhythmias, consisting of single ectopic beats (sEB), multiple EB (mEB), and torsades de pointes (TdP, defined as ≥5 beats with QRS vector twisting around isoelectric line) can be induced in the anesthetized chronic atrioventricular block (CAVB) dog by dofetilide (IKr blocker). The interplay between temporal dispersion of repolarization, quantified as short-term variability (STV), and spatial dispersion of repolarization (SDR) in the initiation and perpetuation of these arrhythmias remains unclear. Five inducible (≥3 TdPs/10 min) CAVB dogs underwent one mapping experiment and were observed for 10 min from the start of dofetilide infusion (0.025 mg/kg, 5 min). An intracardiac decapolar electrogram (EGM) catheter and 30 intramural cardiac needles in the left ventricle (LV) were introduced. STVARI was derived from 31 consecutive activation recovery intervals (ARIs) on the intracardiac EGM, using the formula: . The mean SDR3D in the LV was determined as the three-dimensional repolarization time differences between the intramural cardiac needles. Moments of measurement included baseline (BL) and after dofetilide infusion before first 1) sEB (occurrence at 100 ± 35 s), 2) mEB (224 ± 96 s), and 3) non-self-terminating TdP (454 ± 298 s). STVARI increased from 2.15 ± 0.32 ms at BL to 3.73 ± 0.99 ms* before the first sEB and remained increased without further significant progression to mEB (4.41 ± 0.45 ms*) and TdP (5.07 ± 0.84 ms*) (*P < 0.05 compared with BL). SDR3D did not change from 31 ± 11 ms at BL to 43 ± 13 ms before sEB but increased significantly before mEB (68 ± 7 ms*) and to TdP (86 ± 9 ms*+) (+P < 0.05 compared with sEB). An increase in STV contributes to the initiation of sEB, whereas an increase in SDR is important for the perpetuation of non-self-terminating TdPs. NEW & NOTEWORTHY This study compared two well-established electrophysiological parameters, being temporal and spatial dispersion of repolarization, and provided new insights into their interplay in the arrhythmogenesis of torsades de pointes arrhythmias. Although it confirmed that an increase in temporal dispersion of repolarization contributes to the initiation of single ectopic beats, it showed that an increase in spatial dispersion of repolarization is important for the perpetuation of non-self-terminating torsades de pointes arrhythmias.- 24 July 2018
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 1 (4)
Bridging Organ- and Cellular-Level Behavior in Ex Vivo Experimental Platforms Using Populations of Models of Cardiac Electrophysiology
The inability to discern between pathology and physiological variability is a key issue in cardiac electrophysiology since this prevents the use of minimally invasive acquisitions to predict early pathological behavior. The goal of this work is to demonstrate how experimentally calibrated populations of models (ePoM) may be employed to inform which cellular-level pathologies are responsible for abnormalities observed in organ-level acquisitions while accounting for intersubject variability; this will be done through an exemplary computational and experimental approach. Unipolar epicardial electrograms (EGM) were acquired during an ex vivo porcine heart experiment. A population of the Ten Tusscher 2006 model was calibrated to activation–recovery intervals (ARI), measured from the electrograms, at three representative times. The distributions of the parameters from the resulting calibrated populations were compared to reveal statistically significant pathological variations. Activation–recovery interval reduction was observed in the experiments, and the comparison of the calibrated populations of models suggested a reduced L-type calcium conductance and a high extra-cellular potassium concentration as the most probable causes for the abnormal electrograms. This behavior was consistent with a reduction in the cardiac output (CO) and was confirmed by other experimental measurements. A proof of concept method to infer cellular pathologies by means of organ-level acquisitions is presented, allowing for an earlier detection of pathology than would be possible with current methods. This novel method that uses mathematical models as a tool for formulating hypotheses regarding the cellular causes of observed organ-level behaviors, while accounting for physiological variability has been unexplored.
- 24 July 2018
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 1 (4)
Bridging Organ- and Cellular-Level Behavior in Ex Vivo Experimental Platforms Using Populations of Models of Cardiac Electrophysiology
The inability to discern between pathology and physiological variability is a key issue in cardiac electrophysiology since this prevents the use of minimally invasive acquisitions to predict early pathological behavior. The goal of this work is to demonstrate how experimentally calibrated populations of models (ePoM) may be employed to inform which cellular-level pathologies are responsible for abnormalities observed in organ-level acquisitions while accounting for intersubject variability; this will be done through an exemplary computational and experimental approach. Unipolar epicardial electrograms (EGM) were acquired during an ex vivo porcine heart experiment. A population of the Ten Tusscher 2006 model was calibrated to activation–recovery intervals (ARI), measured from the electrograms, at three representative times. The distributions of the parameters from the resulting calibrated populations were compared to reveal statistically significant pathological variations. Activation–recovery interval reduction was observed in the experiments, and the comparison of the calibrated populations of models suggested a reduced L-type calcium conductance and a high extra-cellular potassium concentration as the most probable causes for the abnormal electrograms. This behavior was consistent with a reduction in the cardiac output (CO) and was confirmed by other experimental measurements. A proof of concept method to infer cellular pathologies by means of organ-level acquisitions is presented, allowing for an earlier detection of pathology than would be possible with current methods. This novel method that uses mathematical models as a tool for formulating hypotheses regarding the cellular causes of observed organ-level behaviors, while accounting for physiological variability has been unexplored.