Passive sampling as an alternative strategy to monitor metals and PAHs trends at an upstream and rural catchment: a French case study
Open Access
- 14 March 2022
- journal article
- research article
- Published by Springer Nature in SN Applied Sciences
- Vol. 4 (4) , 1-13
Abstract
The study presents an alternative strategy to conventional spot sampling for monitoring metals and polycyclic aromatic hydrocarbons (PAHs) at an upstream, rural and karstic catchment in the north eastern part of France, in order to get insight into their spatial and temporal variability. Passive samplers, as diffusive gradients in thin films (DGT) and semipermeable membrane device (SPMD), are monthly deployed from August 2012 to March 2016 at five of the catchment monitoring stations located on the Saulx and Ornain Rivers. An improvement of the frequency of quantification (by a factor 2 to 8, depending on the targeted compound) is observed allowing us to better identify spatial and temporal variability. For instance, the upstream monitoring station on the Saulx River is characterized by high concentrations of Ni and Mn whereas the upstream monitoring station on the Ornain River is enriched in Cu and Zn. Furthermore, five metals (Al, Fe, Mn, Ni, Zn) and three PAHs (fluoranthene, pyrene and chrysene) show significant variations with water levels when grouped in three categories (low, medium and high water levels) in relation with hydrological and climatic patterns. This study leads to a more accurate assessment of the background pollution in metals and PAHs within surface waters than when based on spot sampling data.Keywords
This publication has 26 references indexed in Scilit:
- Spatial and temporal trends in occurrence of emerging and legacy contaminants in the Lower Columbia River 2008–2010Science of The Total Environment, 2014
- Evaluation of trace metals bioavailability in Japanese river waters using DGT and a chemical equilibrium modelWater Research, 2013
- Combining multivariate statistics and analysis of variance to redesign a water quality monitoring networkEnvironmental Science: Processes & Impacts, 2013
- Chemcatcher® and DGT passive sampling devices for regulatory monitoring of trace metals in surface waterJournal of Environmental Monitoring, 2008
- Evaluation of the Chemcatcher and DGT passive samplers for monitoring metals with highly fluctuating water concentrationsJournal of Environmental Monitoring, 2007
- Introduction to emerging tools and their use in water monitoringTrAC Trends in Analytical Chemistry, 2007
- Strategic monitoring for the European Water Framework DirectiveTrAC Trends in Analytical Chemistry, 2006
- Passive sampling techniques for monitoring pollutants in waterTrAC Trends in Analytical Chemistry, 2005
- Evaluation of river water quality monitoring stations by principal component analysisWater Research, 2005
- Sampling frequency for monitoring the actual state of groundwater systemsJournal of Hydrology, 1996