Nathalie Guigues
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nathalie Guigues has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Béatrice Lalere
6 shared publicationsMichèle Desenfant
Laboratoire national de métrologie et d’essais - LNE, Paris, France
3 shared publicationsSandrine Raveau
Laboratoire National de métrologie et d’Essais (LNE), Paris, France
3 shared publicationsBénédicte Lepot
Institut national de l’environnement industriel et des risques - INERIS, Parc Technologique ALATA, Verneuil-en-Halatte, France
2 shared publicationsEmmanuel Hance
ANDRA, Centre Meuse/Haute-Marne
2 shared publicationsJérémie Magar
Veolia Recherche & Innovation (VERI), Pôle Technologies Et Systèmes Industriels, Maisons-Laffitte, France
2 shared publications
Latest Publications
- Open Access
- 21 June 2026
- Published by Elsevier in Measurement
- Vol. 285
New procedure for selection and validation of “reference” TOC analyzers for ultrapure water based on experimental performance
- 21 June 2026
- Published by Elsevier in Measurement
- Vol. 285
Open AccessNew procedure for selection and validation of “reference” TOC analyzers for ultrapure water based on experimental performance
- Open Access
- 11 June 2024
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 149 (16) , 4239-4249
Development of a flow system for decentralized electrochemical analysis of heavy metals using screen-printed electrodes: the importance of sensor stability
Aim: obtain a field-deployable portable box for the online detection of heavy metals in water through an automatable software-assisted procedure and square-wave anodic stripping voltammetry.
- 11 June 2024
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 149 (16) , 4239-4249
Open AccessDevelopment of a flow system for decentralized electrochemical analysis of heavy metals using screen-printed electrodes: the importance of sensor stability
Aim: obtain a field-deployable portable box for the online detection of heavy metals in water through an automatable software-assisted procedure and square-wave anodic stripping voltammetry.
- 8 February 2024
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 29 (2) , 163-173
Insights on the validation of alternative tools for water quality monitoring: the case of on-site test kits, portable devices and continuous measuring devices
- 8 February 2024
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 29 (2) , 163-173
Insights on the validation of alternative tools for water quality monitoring: the case of on-site test kits, portable devices and continuous measuring devices
- Open Access
- 14 March 2022
- Published by Springer Nature in SN Applied Sciences
- Vol. 4 (4) , 1-13
Passive sampling as an alternative strategy to monitor metals and PAHs trends at an upstream and rural catchment: a French case study
The study presents an alternative strategy to conventional spot sampling for monitoring metals and polycyclic aromatic hydrocarbons (PAHs) at an upstream, rural and karstic catchment in the north eastern part of France, in order to get insight into their spatial and temporal variability. Passive samplers, as diffusive gradients in thin films (DGT) and semipermeable membrane device (SPMD), are monthly deployed from August 2012 to March 2016 at five of the catchment monitoring stations located on the Saulx and Ornain Rivers. An improvement of the frequency of quantification (by a factor 2 to 8, depending on the targeted compound) is observed allowing us to better identify spatial and temporal variability. For instance, the upstream monitoring station on the Saulx River is characterized by high concentrations of Ni and Mn whereas the upstream monitoring station on the Ornain River is enriched in Cu and Zn. Furthermore, five metals (Al, Fe, Mn, Ni, Zn) and three PAHs (fluoranthene, pyrene and chrysene) show significant variations with water levels when grouped in three categories (low, medium and high water levels) in relation with hydrological and climatic patterns. This study leads to a more accurate assessment of the background pollution in metals and PAHs within surface waters than when based on spot sampling data.
- 14 March 2022
- Published by Springer Nature in SN Applied Sciences
- Vol. 4 (4) , 1-13
Open AccessPassive sampling as an alternative strategy to monitor metals and PAHs trends at an upstream and rural catchment: a French case study
The study presents an alternative strategy to conventional spot sampling for monitoring metals and polycyclic aromatic hydrocarbons (PAHs) at an upstream, rural and karstic catchment in the north eastern part of France, in order to get insight into their spatial and temporal variability. Passive samplers, as diffusive gradients in thin films (DGT) and semipermeable membrane device (SPMD), are monthly deployed from August 2012 to March 2016 at five of the catchment monitoring stations located on the Saulx and Ornain Rivers. An improvement of the frequency of quantification (by a factor 2 to 8, depending on the targeted compound) is observed allowing us to better identify spatial and temporal variability. For instance, the upstream monitoring station on the Saulx River is characterized by high concentrations of Ni and Mn whereas the upstream monitoring station on the Ornain River is enriched in Cu and Zn. Furthermore, five metals (Al, Fe, Mn, Ni, Zn) and three PAHs (fluoranthene, pyrene and chrysene) show significant variations with water levels when grouped in three categories (low, medium and high water levels) in relation with hydrological and climatic patterns. This study leads to a more accurate assessment of the background pollution in metals and PAHs within surface waters than when based on spot sampling data.
- 13 January 2022
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 27 (1) , 43-53
Assessing the performances of on-line analyzers can greatly improve free chlorine monitoring in drinking water
- 13 January 2022
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 27 (1) , 43-53
Assessing the performances of on-line analyzers can greatly improve free chlorine monitoring in drinking water
- 30 October 2019
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 25 (1) , 7-22
Assessing the performance of measurement devices for continuously monitoring of organic matter and nutrient in river water
- 30 October 2019
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 25 (1) , 7-22
Assessing the performance of measurement devices for continuously monitoring of organic matter and nutrient in river water
- 21 December 2015
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 21 (2) , 101-112
Estimating sampling and analysis uncertainties to assess the fitness for purpose of a water quality monitoring network
- 21 December 2015
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 21 (2) , 101-112
Estimating sampling and analysis uncertainties to assess the fitness for purpose of a water quality monitoring network
- 5 August 2013
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 15 (9) , 1692-1705
Combining multivariate statistics and analysis of variance to redesign a water quality monitoring network
The objective of this paper was to demonstrate how multivariate statistics combined with the analysis of variance could support decision-making during the process of redesigning a water quality monitoring network with highly heterogeneous datasets in terms of time and space. Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA) were selected to optimise the selection of water quality parameters to be monitored as well as the number and location of monitoring stations. Sampling frequency was specifically investigated through the analysis of variance. The data used were obtained between 2007 and 2010 at the Long-term Environmental Research Monitoring and Testing System (OPE) located in the north-eastern part of France in relation with a geological disposal of radioactive waste project. PCA results showed that no substantial reduction among the parameters was possible as strong correlation only exists between electrical conductivity, calcium or bicarbonates. HCA results were geospatially represented for each field campaign and compared to one another in terms of similarities and differences allowing us to group the monitoring stations into 12 categories. This approach enabled us to take into account not only the spatial variability of water quality but also its temporal variability. Finally, the analysis of variances showed that three very different behaviours occurred: parameters with high temporal variability and low spatial variability (e.g. suspended matter), parameters with high spatial variability and average temporal variability (e.g. calcium) and finally parameters with both high temporal and spatial variability (e.g. nitrate).
- 5 August 2013
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 15 (9) , 1692-1705
Combining multivariate statistics and analysis of variance to redesign a water quality monitoring network
The objective of this paper was to demonstrate how multivariate statistics combined with the analysis of variance could support decision-making during the process of redesigning a water quality monitoring network with highly heterogeneous datasets in terms of time and space. Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA) were selected to optimise the selection of water quality parameters to be monitored as well as the number and location of monitoring stations. Sampling frequency was specifically investigated through the analysis of variance. The data used were obtained between 2007 and 2010 at the Long-term Environmental Research Monitoring and Testing System (OPE) located in the north-eastern part of France in relation with a geological disposal of radioactive waste project. PCA results showed that no substantial reduction among the parameters was possible as strong correlation only exists between electrical conductivity, calcium or bicarbonates. HCA results were geospatially represented for each field campaign and compared to one another in terms of similarities and differences allowing us to group the monitoring stations into 12 categories. This approach enabled us to take into account not only the spatial variability of water quality but also its temporal variability. Finally, the analysis of variances showed that three very different behaviours occurred: parameters with high temporal variability and low spatial variability (e.g. suspended matter), parameters with high spatial variability and average temporal variability (e.g. calcium) and finally parameters with both high temporal and spatial variability (e.g. nitrate).