Optical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chronic total occlusions” (PRISON IV) trial
Authors:
- Eva SpoormansESEva Spoormans
- Johan BennettJBJohan Bennett
- Christophe DuboisCDChristophe Dubois
- Walter DesmetWDWalter Desmet
- Giovanni UghiGUGiovanni Ughi
- Ann BelmansABAnn Belmans
- Johannes KelderJKJohannes Kelder
- Jan TijssenJTJan Tijssen
- Pierfrancesco AgostoniPAPierfrancesco Agostoni
- Maarten SuttorpMSMaarten Suttorp
- Tom AdriaenssensTATom Adriaenssens
- 1 August 2017
- journal article
- research article
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 13 (5) , e522-e530
Abstract
The PRISON IV trial investigated the next-generation sirolimus-eluting stent (SES) with ultra-thin struts and biodegradable polymer against the second-generation everolimus-eluting stent (EES) with thin struts and durable polymer in patients with successfully recanalised chronic total occlusions (CTO). In this study, we examined the secondary optical coherence tomography endpoints. The main PRISON IV trial randomised 330 patients to either SES or EES. At nine months, 281 (85%) patients underwent repeat angiography. Of these, 60 consecutive patients received optical coherence tomography divided over both stent groups. The mean number of struts analysed was 750±337 and 633±358 in SES and EES patients, respectively (p=0.07). The minimal lumen area, minimal stent area, maximal neointima area and neointimal thickness were comparable between the groups (4.8±2.1 and 4.4±1.5 mm2; 5.3±1.8 and 5.3±1.4 mm2; 2.5±2.0 and 2.2±1.5 mm2; 0.7±1.7 and 0.4±0.2 mm). The percentage of uncovered struts was higher with EES (6.2±7.5% and 11.9±13.4%, p=0.04), whereas the percentage of malapposed struts and mean number of coronary evaginations were significantly higher with SES (2.9±4.0% and 1.2±2.4%, p=0.02; 18.5±17.7 and 5.3±3.1, p=0.004). The optical coherence tomography findings of this substudy demonstrated improved strut coverage with ultra-thin strut SES with bioresorbable polymer compared to thin-strut EES with durable polymer in CTO. On the other hand, SES showed a higher rate of stent strut malappositon and coronary evaginations. The clinical relevance of these findings remains to be demonstrateKeywords
This publication has 15 references indexed in Scilit:
- Randomized Multicenter Trial Investigating Angiographic Outcomes of Hybrid Sirolimus-Eluting Stents With Biodegradable Polymer Compared With Everolimus-Eluting Stents With Durable Polymer in Chronic Total OcclusionsJACC: Cardiovascular Interventions, 2017
- Five-year outcomes of chronic total occlusion treatment with a biolimus A9-eluting biodegradable polymer stent versus a sirolimus-eluting permanent polymer stent in the LEADERS all-comers trialCardiology Journal, 2016
- Optical coherence tomography findings after chronic total occlusion interventions: Insights from the “AngiographiC evaluation of the everolimus-eluting stent in chronic Total occlusions” (ACE-CTO) study (NCT01012869)Cardiovascular Revascularization Medicine, 2016
- STACCATO (Assessment of Stent sTrut Apposition and Coverage in Coronary ArTeries with Optical coherence tomography in patients with STEMI, NSTEMI and stable/unstable angina undergoing everolimus vs. biolimus A9-eluting stent implantation): a randomised controlled trialEuroIntervention, 2016
- Mechanisms of Very Late Drug-Eluting Stent Thrombosis Assessed by Optical Coherence TomographyCirculation, 2016
- Safety and Efficacy of Everolimus- Versus Sirolimus-Eluting StentsJACC, 2016
- Delayed coverage of drug-eluting stents after interventional revascularisation of chronic total occlusions assessed by optical coherence tomography: the ALSTER-OCT-CTO registryEuroIntervention, 2016
- Comparison of a Novel Biodegradable Polymer Sirolimus-Eluting Stent With a Durable Polymer Everolimus-Eluting StentCirculation: Cardiovascular Interventions, 2015
- Coronary evaginations are associated with positive vessel remodelling and are nearly absent following implantation of newer-generation drug-eluting stents: an optical coherence tomography and intravascular ultrasound studyEuropean Heart Journal, 2013
- Automatic segmentation of in-vivo intra-coronary optical coherence tomography images to assess stent strut apposition and coverageThe International Journal of Cardiovascular Imaging, 2011