Port protectors in clinical practice: an audit
Author:
- 28 April 2016
- journal article
- research article
- Published by Mark Allen Group in British Journal of Nursing
- Vol. 25 (8) , S25-S31
Abstract
This article discusses the effect on compliance and incidence of vascular access device (VAD)-related bacteraemia following the introduction of a passive disinfection device (Curos®) for 6 months in four areas at one hospital trust. The hospital's infection prevention and control team replaced the ‘active’ disinfection using a disinfection wipe with ‘scrub the hub’. Disinfection wipes used for needle-free devices were removed from all four trial areas and Curos was incorporated into the aseptic non-touch technique (ANTT®) protocols for the trial wards. Staff training was provided before and during the study, and audits of staff compliance with Curos placement were undertaken monthly. A benchmarking audit of ‘scrub the hub’ techniques was conducted 1 month before audit began. The results of the audit showed VAD-related bacteraemia rates reduced by 69% from 26 cases (confirmed through review of blood culture laboratory data and source identified by consultant microbiologists) before the study, to 8 when staff compliance with Curos placement onto VADs was 80% or more.Keywords
This publication has 11 references indexed in Scilit:
- Strategies to Prevent Central Line–Associated Bloodstream Infections in Acute Care Hospitals: 2014 UpdateInfection Control & Hospital Epidemiology, 2014
- epic3: National Evidence-Based Guidelines for Preventing Healthcare-Associated Infections in NHS Hospitals in EnglandJournal of Hospital Infection, 2014
- AnIn Vitroevaluation of disinfection protocols used for needleless connectors of central venous cathetersLetters in Applied Microbiology, 2013
- Impact of alcohol-impregnated port protectors and needleless neutral pressure connectors on central line–associated bloodstream infections and contamination of blood cultures in an inpatient oncology unitAmerican Journal of Infection Control, 2012
- “Scrub the Hub”Critical Care Nursing Quarterly, 2011
- In vitro and in vivo evaluation of efficacy of citrate/methylene blue/parabens/IPA solution as a skin disinfectantJournal of Infection, 2010
- Improving standards of aseptic practice through an ANTT trust-wide implementation process: a matter of prioritisation and careJournal of Infection Prevention, 2009
- Strategies to Prevent Central Line–Associated Bloodstream Infections in Acute Care HospitalsInfection Control & Hospital Epidemiology, 2008
- Successful Disinfection of Needleless Access Ports: A Matter of Time and FrictionJournal of the Association for Vascular Access, 2007
- Use of chlorhexidine-impregnated dressing to prevent vascular and epidural catheter colonization and infection: a meta-analysisJournal of Antimicrobial Chemotherapy, 2006