MULTI‐parametric MR imaging with fLEXible design (MULTIPLEX)
Authors:
- 31 August 2021
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (2) , 658-673
Abstract
Purpose: To introduce a gradient echo (GRE) ‐based method, namely MULTIPLEX, for single‐scan 3D multi‐parametric MRI with high resolution, signal‐to‐noise ratio (SNR), accuracy, efficiency, and acquisition flexibility.Theory: With a comprehensive design with dual‐repetition time (TR), dual flip angle (FA), multi‐echo, and optional flow modulation features, the MULTIPLEX signals contain information on radiofrequency (RF) B1t fields, proton density, T1, susceptibility and blood flows, facilitating multiple qualitative images and parametric maps.Methods: MULTIPLEX was evaluated on system phantom and human brains, via visual inspection for image contrasts and quality or quantitative evaluation via simulation, phantom scans and literature comparison. Region‐of‐interest (ROI) analysis was performed on parametric maps of the system phantom and brain scans, extracting the mean and SD of the T1, , proton density (PD), and/or quantitative susceptibility mapping (QSM) values for comparison with reference values or literature.Results: One MULTIPLEX scan offers multiple sets of images, including but not limited to: composited PDW/T1W/W, aT1W, SWI, MRA (optional), B1t map, T1 map, / maps, PD map, and QSM. The quantitative error of phantom T1, and PD mapping were 3) whole brain coverage were about 7.5 min, while processing times were <1 min. With flow modulation, additional MRA images can be obtained without affecting the quality or accuracy of other images.Conclusion: The proposed MUTLIPLEX method possesses great potential for multi‐parametric MR imaging.Keywords
This publication has 35 references indexed in Scilit:
- Mapping of low flip angles in magnetic resonancePhysics in Medicine & Biology, 2011
- Chemical shift–based water/fat separation: A comparison of signal modelsMagnetic Resonance in Medicine, 2010
- Susceptibility weighted imaging with multiple echoesJournal of Magnetic Resonance Imaging, 2009
- Hybrid of opposite‐contrast MR angiography (HOP‐MRA) combining time‐of‐flight and flow‐sensitive black‐blood contrastsMagnetic Resonance in Medicine, 2009
- Age-Dependent Normal Values of T2* and T2′ in Brain ParenchymaAmerican Journal of Neuroradiology, 2008
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007
- High‐resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high‐speed incorporation of RF field inhomogeneities (DESPOT1‐HIFI)Journal of Magnetic Resonance Imaging, 2007
- Actual flip‐angle imaging in the pulsed steady state: A method for rapid three‐dimensional mapping of the transmitted radiofrequency fieldMagnetic Resonance in Medicine, 2006
- Rapid high‐resolution T1 mapping by variable flip angles: Accurate and precise measurements in the presence of radiofrequency field inhomogeneityMagnetic Resonance in Medicine, 2006
- SMASH, SENSE, PILS, GRAPPATopics in Magnetic Resonance Imaging, 2004