Abstract
Purpose: To investigate the extent of anterior chamber angle circumference needed to maintain a physiological outflow facility (C). Methods: Twenty anterior segments of porcine eyes were assigned to 5 groups, each with a different degree of cyanoacrylate-mediated angle closure: 90° (n = 4), 180° (n = 4), 270° (n = 4), 360° (n = 4) and four unoccluded control eyes. The outflow facility was measured at baseline, 3, 12, 24, and 36 hours after angle closure. Outflow patterns were evaluated with canalograms and the histomorphology was compared. Results: Baseline outflow facilities of the five groups were similar (F = 0.922, P = 0.477). Complete, circumferential occlusion over 360° induced a significant decrease in facility from baseline at all time-points (P ≤ 0.023 at 3, 12, 24 and 36 hours). However, no difference from baseline was found in any of the partially-occluded (0–270°) groups (F ≥ 0.067, P ≥ 0.296 at 3, 12, 24 and 36 hours). The canalograms confirmed the extent of occlusion with flow through the unblocked regions. Histology revealed no adverse effects of blockage on the TM or aqueous plexus in the unoccluded angle portions. The unoccluded TM appeared normal. Conclusion: Cyanoacrylate-mediated angle occlusion created a reproducible angle closure model. 90° of unoccluded anterior chamber angle circumference was sufficient to maintain physiological outflow. This model may help understand how outflow can be regulated in healthy, nonglaucomatous TM.Keywords
All Related Versions
This publication has 41 references indexed in Scilit:
- Gene transfer to the outflow tractExperimental Eye Research, 2017
- Variations in active outflow along the trabecular outflow pathwayExperimental Eye Research, 2016
- Aqueous outflow: Segmental and distal flowJournal of Cataract & Refractive Surgery, 2014
- Cyanoacrylate: A Handy Tissue Glue in Maxillofacial Surgery: Our Experience in Alexandria, EgyptJournal of Maxillofacial and Oral Surgery, 2012
- Novel Association of Smaller Anterior Chamber Width with Angle Closure in SingaporeansOphthalmology, 2010
- The trabecular meshwork outflow pathways: Structural and functional aspectsExperimental Eye Research, 2009
- Skin graft fixation with cyanoacrylate tissue adhesive in burn patientsBurns, 2007
- Goldmann's equation and clinical measures of aqueous dynamicsExperimental Eye Research, 2004
- Does Pigmentation Affect the Trabecular Meshwork?Archives of Ophthalmology (1950), 1989
- Pressure dependency of transcleral flowExperimental Eye Research, 1977