Priyal Shah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Priyal Shah has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Nils A. Loewen
Department of Ophthalmology, University of Würzburg, Würzburg, Germany
7 shared publications - Chao Wang
Department of Ophthalmology University of Pittsburgh Medical Center Pittsburgh Pennsylvania United States
5 shared publications - Hamed Esfandiari
Department of Ophthalmology University of Pittsburgh Medical Center Pittsburgh Pennsylvania United States
5 shared publications - Ralitsa T. Loewen
Department of Ophthalmology University of Pittsburgh Medical Center Pittsburgh Pennsylvania United States
5 shared publications - Susannah Waxman
Department of Ophthalmology, University of Pittsburgh School of Medicine, Pittsburgh, USA
5 shared publications - Yalong Dang
Department of Ophthalmology, Sanmenxia Eye Hospital/Sanmenxia Central Hospital Affiliated to Henan University of Science and Technology, Sanmenxia, China
4 shared publications
Latest Publications
- Open Access
- 27 November 2018
- Published by MDPI AG in Preprints.org
Outflow Facility and Extent of Angle Closure in a Porcine Model
Purpose: To investigate the extent of anterior chamber angle circumference needed to maintain a physiological outflow facility (C). Methods: Twenty anterior segments of porcine eyes were assigned to 5 groups, each with a different degree of cyanoacrylate-mediated angle closure: 90° (n = 4), 180° (n = 4), 270° (n = 4), 360° (n = 4) and four unoccluded control eyes. The outflow facility was measured at baseline, 3, 12, 24, and 36 hours after angle closure. Outflow patterns were evaluated with canalograms and the histomorphology was compared. Results: Baseline outflow facilities of the five groups were similar (F = 0.922, P = 0.477). Complete, circumferential occlusion over 360° induced a significant decrease in facility from baseline at all time-points (P ≤ 0.023 at 3, 12, 24 and 36 hours). However, no difference from baseline was found in any of the partially-occluded (0–270°) groups (F ≥ 0.067, P ≥ 0.296 at 3, 12, 24 and 36 hours). The canalograms confirmed the extent of occlusion with flow through the unblocked regions. Histology revealed no adverse effects of blockage on the TM or aqueous plexus in the unoccluded angle portions. The unoccluded TM appeared normal. Conclusion: Cyanoacrylate-mediated angle occlusion created a reproducible angle closure model. 90° of unoccluded anterior chamber angle circumference was sufficient to maintain physiological outflow. This model may help understand how outflow can be regulated in healthy, nonglaucomatous TM.
- 27 November 2018
- Published by MDPI AG in Preprints.org
Open AccessOutflow Facility and Extent of Angle Closure in a Porcine Model
Purpose: To investigate the extent of anterior chamber angle circumference needed to maintain a physiological outflow facility (C). Methods: Twenty anterior segments of porcine eyes were assigned to 5 groups, each with a different degree of cyanoacrylate-mediated angle closure: 90° (n = 4), 180° (n = 4), 270° (n = 4), 360° (n = 4) and four unoccluded control eyes. The outflow facility was measured at baseline, 3, 12, 24, and 36 hours after angle closure. Outflow patterns were evaluated with canalograms and the histomorphology was compared. Results: Baseline outflow facilities of the five groups were similar (F = 0.922, P = 0.477). Complete, circumferential occlusion over 360° induced a significant decrease in facility from baseline at all time-points (P ≤ 0.023 at 3, 12, 24 and 36 hours). However, no difference from baseline was found in any of the partially-occluded (0–270°) groups (F ≥ 0.067, P ≥ 0.296 at 3, 12, 24 and 36 hours). The canalograms confirmed the extent of occlusion with flow through the unblocked regions. Histology revealed no adverse effects of blockage on the TM or aqueous plexus in the unoccluded angle portions. The unoccluded TM appeared normal. Conclusion: Cyanoacrylate-mediated angle occlusion created a reproducible angle closure model. 90° of unoccluded anterior chamber angle circumference was sufficient to maintain physiological outflow. This model may help understand how outflow can be regulated in healthy, nonglaucomatous TM.
- Open Access
- 9 July 2018
- Published by MDPI AG in Preprints.org
RKI-1447, a Rho-Kinase Inhibitor Causes Ocular Hypotension, Actin Stress Fiber Disruption and Increased Phagocytosis
Purpose: This study investigated the hypotensive effect of RKI-1447, a Rho kinase inhibitor, in a porcine ex vivo pigmentary glaucoma model. Methods: Twenty-eight porcine anterior chambers were perfused with medium supplemented with 1.67 × 107 pigment particles/mL for 48 hours before treatment with RKI-1447 (n = 16) or vehicle control (n = 12). Intraocular pressure (IOP) was recorded and outflow facility was calculated. Primary trabecular meshwork cells were exposed to RKI-1447 or vehicle control; effects on the cytoskeleton, motility, and phagocytosis were evaluated. Result: Compared to baseline, the perfusion of pigment caused a significant increase in IOP in the RKI-1447 group (P = 0.003) at 48 hours. Subsequent treatment with RKI-1447 significantly reduced IOP from 20.14 ± 2.59 mmHg to 13.38 ± 0.91 mmHg (P = 0.02). Pigment perfusion reduced the outflow facility from 0.27 ± 0.03 at baseline to 0.18 ± 0.02 at 48 hours (P < 0.001). This was partially reversed with RKI-1447. RKI-1447 caused no apparent histological changes in the micro- or macroscopic TM appearance. RKI-1447-treated primary TM cells showed significant disruption of the actin cytoskeleton both in the presence and absence of pigment (P < 0.001) but no effect on TM migration was observed. Pigment-treated TM cells exhibited a reduction in TM phagocytosis, which RKI-1447 reversed. Conclusion: RKI-1447 significantly reduces IOP by disrupting TM stress fibers and increasing TM phagocytosis. These features may make it useful for the treatment of secondary glaucomas with an increased phagocytic load.
- 9 July 2018
- Published by MDPI AG in Preprints.org
Open AccessRKI-1447, a Rho-Kinase Inhibitor Causes Ocular Hypotension, Actin Stress Fiber Disruption and Increased Phagocytosis
Purpose: This study investigated the hypotensive effect of RKI-1447, a Rho kinase inhibitor, in a porcine ex vivo pigmentary glaucoma model. Methods: Twenty-eight porcine anterior chambers were perfused with medium supplemented with 1.67 × 107 pigment particles/mL for 48 hours before treatment with RKI-1447 (n = 16) or vehicle control (n = 12). Intraocular pressure (IOP) was recorded and outflow facility was calculated. Primary trabecular meshwork cells were exposed to RKI-1447 or vehicle control; effects on the cytoskeleton, motility, and phagocytosis were evaluated. Result: Compared to baseline, the perfusion of pigment caused a significant increase in IOP in the RKI-1447 group (P = 0.003) at 48 hours. Subsequent treatment with RKI-1447 significantly reduced IOP from 20.14 ± 2.59 mmHg to 13.38 ± 0.91 mmHg (P = 0.02). Pigment perfusion reduced the outflow facility from 0.27 ± 0.03 at baseline to 0.18 ± 0.02 at 48 hours (P < 0.001). This was partially reversed with RKI-1447. RKI-1447 caused no apparent histological changes in the micro- or macroscopic TM appearance. RKI-1447-treated primary TM cells showed significant disruption of the actin cytoskeleton both in the presence and absence of pigment (P < 0.001) but no effect on TM migration was observed. Pigment-treated TM cells exhibited a reduction in TM phagocytosis, which RKI-1447 reversed. Conclusion: RKI-1447 significantly reduces IOP by disrupting TM stress fibers and increasing TM phagocytosis. These features may make it useful for the treatment of secondary glaucomas with an increased phagocytic load.
- Open Access
- 27 June 2018
- Published by MDPI AG in Preprints.org
Intraocular Pressure Reduction in a Pigmentary Glaucoma Model by Goniotome Ab Interno Trabeculectomy
Purpose: To investigate whether microsurgical excision of trabecular meshwork (TM) in an ex vivo pigmentary glaucoma model can normalize the hypertensive phenotype. Methods: Eight eyes of a porcine pigmentary glaucoma model underwent 90° of microsurgical TM excision with an aspirating dual-blade (Goniotome (G)). 24 hours later, an additional 90° of TM were removed. Anterior segments with sham surgeries served as the control (C). Outflow facility and intraocular pressure (IOP) were analyzed. Histology with hematoxylin and eosin (H&E) was obtained. Results: After the first 90° TM excision, IOP was significantly lower in G (10.23±2.39 mmHg, n=7) than C (20.04±1.97mmHg, n=8, PConclusion: Excision of 90° of TM in a pigmentary glaucoma model using an aspirating dual-blade decreased IOP and increased outflow facility. Translational Relevance: Microsurgical TM excision over 90° can effectively restore outflow in pigmentary glaucoma.
- 27 June 2018
- Published by MDPI AG in Preprints.org
Open AccessIntraocular Pressure Reduction in a Pigmentary Glaucoma Model by Goniotome Ab Interno Trabeculectomy
Purpose: To investigate whether microsurgical excision of trabecular meshwork (TM) in an ex vivo pigmentary glaucoma model can normalize the hypertensive phenotype. Methods: Eight eyes of a porcine pigmentary glaucoma model underwent 90° of microsurgical TM excision with an aspirating dual-blade (Goniotome (G)). 24 hours later, an additional 90° of TM were removed. Anterior segments with sham surgeries served as the control (C). Outflow facility and intraocular pressure (IOP) were analyzed. Histology with hematoxylin and eosin (H&E) was obtained. Results: After the first 90° TM excision, IOP was significantly lower in G (10.23±2.39 mmHg, n=7) than C (20.04±1.97mmHg, n=8, PConclusion: Excision of 90° of TM in a pigmentary glaucoma model using an aspirating dual-blade decreased IOP and increased outflow facility. Translational Relevance: Microsurgical TM excision over 90° can effectively restore outflow in pigmentary glaucoma.
- Open Access
- 19 April 2018
- Published by MDPI AG in Preprints.org
Five-Year Clinical Outcomes of Trabectome Surgery at a Single Glaucoma Center
Purpose: To analyze the five-year results of Trabectome ab interno trabeculectomy of a single glaucoma center. Method: In this retrospective interventional single-center case series, data of 93 patients undergoing ab interno trabeculotomy between September 2010, and December 2012 were included. Kaplan-Meier analysis was performed using success criteria defined as postoperative intraocular pressure (IOP) ≤21 mm Hg, or >20% reduction from preoperative IOP, and no need for further glaucoma surgery. Risk factors for failure were identified using Cox proportional hazards ratio (HR). Results: The retention rate for five years follow-up was 66%. The cumulative probability of success at 1, 2, 3, 4 and 5 years was 82.6%, 76.7%, 73.9%, 72.3%, and 67.5%. Risk factors for failure were lower baseline IOP (HR=0.27, P=0.001), younger age (HR=0.25, P=0.02), and higher central corneal thickness (HR=0.18, P= 0.01). Pseudoexfoliation was associated with a higher success rate (HR= 0.39, P=0.02). IOP was decreased significantly from 20.0±5.6 mmHg at baseline to 15.6±4.6 mmHg at 5-year follow-up (P=0.001). The baseline number of glaucoma medications was 1.8±1.2, which decreased to 1.0±1.2 medications at 5 years. Conclusion: Trabectome surgery was associated with a good long-term efficacy and safety profile in this single-center case series with a high retention rate. A higher baseline IOP, older age, thinner cornea, and pseudoexfoliation glaucoma were associated with a higher success rate.
- 19 April 2018
- Published by MDPI AG in Preprints.org
Open AccessFive-Year Clinical Outcomes of Trabectome Surgery at a Single Glaucoma Center
Purpose: To analyze the five-year results of Trabectome ab interno trabeculectomy of a single glaucoma center. Method: In this retrospective interventional single-center case series, data of 93 patients undergoing ab interno trabeculotomy between September 2010, and December 2012 were included. Kaplan-Meier analysis was performed using success criteria defined as postoperative intraocular pressure (IOP) ≤21 mm Hg, or >20% reduction from preoperative IOP, and no need for further glaucoma surgery. Risk factors for failure were identified using Cox proportional hazards ratio (HR). Results: The retention rate for five years follow-up was 66%. The cumulative probability of success at 1, 2, 3, 4 and 5 years was 82.6%, 76.7%, 73.9%, 72.3%, and 67.5%. Risk factors for failure were lower baseline IOP (HR=0.27, P=0.001), younger age (HR=0.25, P=0.02), and higher central corneal thickness (HR=0.18, P= 0.01). Pseudoexfoliation was associated with a higher success rate (HR= 0.39, P=0.02). IOP was decreased significantly from 20.0±5.6 mmHg at baseline to 15.6±4.6 mmHg at 5-year follow-up (P=0.001). The baseline number of glaucoma medications was 1.8±1.2, which decreased to 1.0±1.2 medications at 5 years. Conclusion: Trabectome surgery was associated with a good long-term efficacy and safety profile in this single-center case series with a high retention rate. A higher baseline IOP, older age, thinner cornea, and pseudoexfoliation glaucoma were associated with a higher success rate.
- Open Access
- 27 March 2018
- Published by MDPI AG in Preprints.org
Outflow Enhancement by Three Different ab Interno Trabeculectomy Procedures in a Porcine Anterior Segment Model
Purpose: To evaluate three different microincisional ab interno trabeculectomy procedures in a porcine eye perfusion model. Methods: In perfused porcine anterior segments, 90 degrees of trabecular meshwork (TM) were ablated using the Trabectome (T; n = 8), Goniotome (G; n = 8), or Kahook device (K; n = 8). After 24 hours, additional 90 degrees of TM were removed. Intraocular pressure (IOP) and outflow facility were measured at 5 µL/min and 10 µL/min perfusion to simulate an elevated IOP. Structure and function were assessed with canalograms and histology. Results: At 5 µL/min infusion rate, T resulted in a greater IOP reduction than G or K from baseline (76.12% decrease versus 48.19% and 47.96%, P = 0.013). IOP reduction between G and K was similar (P = 0.420). Removing another 90 degrees of TM caused an additional IOP reduction only in T and G but not in K. Similarly, T resulted in the largest increase in outflow facility at 5 µL/min compared with G and K (first ablation: 3.41 times increase versus 1.95 and 1.87; second ablation: 4.60 versus 2.50 and 1.74) with similar results at 10 µL/min (first ablation: 3.28 versus 2.29 and 1.90 (P = 0.001); second ablation: 4.10 versus 3.01 and 2.01 (P = 0.001)). Canalograms indicated circumferential flow beyond the ablation endpoints. Conclusions: T, G and K significantly increased the outflow facility. In this model, T had a larger effect than G and K.
- 27 March 2018
- Published by MDPI AG in Preprints.org
Open AccessOutflow Enhancement by Three Different ab Interno Trabeculectomy Procedures in a Porcine Anterior Segment Model
Purpose: To evaluate three different microincisional ab interno trabeculectomy procedures in a porcine eye perfusion model. Methods: In perfused porcine anterior segments, 90 degrees of trabecular meshwork (TM) were ablated using the Trabectome (T; n = 8), Goniotome (G; n = 8), or Kahook device (K; n = 8). After 24 hours, additional 90 degrees of TM were removed. Intraocular pressure (IOP) and outflow facility were measured at 5 µL/min and 10 µL/min perfusion to simulate an elevated IOP. Structure and function were assessed with canalograms and histology. Results: At 5 µL/min infusion rate, T resulted in a greater IOP reduction than G or K from baseline (76.12% decrease versus 48.19% and 47.96%, P = 0.013). IOP reduction between G and K was similar (P = 0.420). Removing another 90 degrees of TM caused an additional IOP reduction only in T and G but not in K. Similarly, T resulted in the largest increase in outflow facility at 5 µL/min compared with G and K (first ablation: 3.41 times increase versus 1.95 and 1.87; second ablation: 4.60 versus 2.50 and 1.74) with similar results at 10 µL/min (first ablation: 3.28 versus 2.29 and 1.90 (P = 0.001); second ablation: 4.10 versus 3.01 and 2.01 (P = 0.001)). Canalograms indicated circumferential flow beyond the ablation endpoints. Conclusions: T, G and K significantly increased the outflow facility. In this model, T had a larger effect than G and K.
- Open Access
- 5 February 2018
- Published by MDPI AG in Preprints.org
Ocular Hypotension, Actin Stress Fiber Disruption and Phagocytosis Increase by RKI-1447, a Rho-Kinase Inhibitor
Objective: The Rho GTPase/Rho kinase pathway is an important target in glaucoma treatment. This study investigated the hypotensive effect of RKI-1447, a Rho kinase inhibitor developed for cancer treatment, in a porcine ex vivo pigmentary glaucoma model. Materials and Methods: Twenty-eight fresh porcine anterior chambers were perfused with pigment medium (1.67 × 107 pigment particles/mL) for 48 hours before being subjected to the RKI-1447 (n = 16) or the vehicle control (n = 12). Another twelve eyes with normal medium perfusion served as the control. The intraocular pressure (IOP) was recorded at two-minute intervals and the outflow facility was calculated. To investigate the intracellular mechanism of the IOP reduction, primary trabecular meshwork cells were exposed to RKI-1447 or the vehicle control and then analyzed for changes in cytoskeleton, motility, and phagocytosis. Results: Compared to the baseline, the perfusion of pigment caused a significant increase in IOP in the RKI-1447 group (P = 0.003) at 48 hours. Subsequent treatment with RKI-1447 significantly reduced IOP from 20.14 ± 2.59 mmHg to 13.38 ± 0.91 mmHg (P = 0.02). Pigment perfusion reduced the outflow facility from 0.27 ± 0.03 at baseline to 0.18 ± 0.02 at 48 hours (P < 0.001). This was partially reversed with RKI-1447. RKI-1447 exhibited no apparent changes in the micro- or macroscopic appearance, including histology. Primary TM cells exposed to RKI-1447 showed a significant disruption of the actin cytoskeleton both in the presence and absence of pigment exposure (P < 0.001) but no effect on TM migration was observed. Pigment-treated TM cells exhibited a reduction in TM phagocytosis, which RKI reversed. Conclusions: RKI-1447 is a novel ROCK inhibitor that significantly reduces IOP by disrupting TM stress fibers and increasing TM phagocytosis. These features may make it especially useful for the treatment of secondary glaucomas with an increased phagocytosis load but also for other open angle glaucomas.
- 5 February 2018
- Published by MDPI AG in Preprints.org
Open AccessOcular Hypotension, Actin Stress Fiber Disruption and Phagocytosis Increase by RKI-1447, a Rho-Kinase Inhibitor
Objective: The Rho GTPase/Rho kinase pathway is an important target in glaucoma treatment. This study investigated the hypotensive effect of RKI-1447, a Rho kinase inhibitor developed for cancer treatment, in a porcine ex vivo pigmentary glaucoma model. Materials and Methods: Twenty-eight fresh porcine anterior chambers were perfused with pigment medium (1.67 × 107 pigment particles/mL) for 48 hours before being subjected to the RKI-1447 (n = 16) or the vehicle control (n = 12). Another twelve eyes with normal medium perfusion served as the control. The intraocular pressure (IOP) was recorded at two-minute intervals and the outflow facility was calculated. To investigate the intracellular mechanism of the IOP reduction, primary trabecular meshwork cells were exposed to RKI-1447 or the vehicle control and then analyzed for changes in cytoskeleton, motility, and phagocytosis. Results: Compared to the baseline, the perfusion of pigment caused a significant increase in IOP in the RKI-1447 group (P = 0.003) at 48 hours. Subsequent treatment with RKI-1447 significantly reduced IOP from 20.14 ± 2.59 mmHg to 13.38 ± 0.91 mmHg (P = 0.02). Pigment perfusion reduced the outflow facility from 0.27 ± 0.03 at baseline to 0.18 ± 0.02 at 48 hours (P < 0.001). This was partially reversed with RKI-1447. RKI-1447 exhibited no apparent changes in the micro- or macroscopic appearance, including histology. Primary TM cells exposed to RKI-1447 showed a significant disruption of the actin cytoskeleton both in the presence and absence of pigment exposure (P < 0.001) but no effect on TM migration was observed. Pigment-treated TM cells exhibited a reduction in TM phagocytosis, which RKI reversed. Conclusions: RKI-1447 is a novel ROCK inhibitor that significantly reduces IOP by disrupting TM stress fibers and increasing TM phagocytosis. These features may make it especially useful for the treatment of secondary glaucomas with an increased phagocytosis load but also for other open angle glaucomas.
- Open Access
- 5 February 2018
- Published by MDPI AG in Preprints.org
Impact of Same-Session Trabectome Surgery on Ahmed Glaucoma Valve Outcomes
Purpose: To evaluate the efficacy and survival rates of same session ab interno trabeculectomy with the trabectome and Ahmed glaucoma valve implant (AT) in comparison to the Ahmed glaucoma valve alone (A). Method: A total of 107 eyes undergoing primary glaucoma surgery were enrolled in this retrospective comparative case series, including 48 eyes which underwent AT and 59 eyes which received A alone. Participants were identified using the procedural terminology codes, and their medical records were reviewed. The primary outcome measure was surgical success, defined as intraocular pressure (IOP) > 5 mmHg, ≤ 21 mmHg, and IOP reduction ≥ 20% from baseline at two consecutive visits after three months, no reoperation for glaucoma. Secondary outcome measures were IOP, the number of glaucoma medications, incidence of a hypertensive phase, and best corrected visual acuity (BCVA). Results: The cumulative probability of success at one year was 70% in AT, and 65% in A (p=0.85). IOP decreased significantly from 26.6 ± 10.1 mmHg at baseline to 14.7 ± 3.3 mmHg at the final follow-up in AT (p= 0.001). The corresponding numbers for A were 28.8 ± 10.2 and 16.7 ± 4.9, respectively (p= 0.001). The final IOP was significantly lower in AT (p= 0.022). The number of medications at baseline was comparable in both groups (2.6 ± 1.2 in AT and 2.5 ± 1.3 in A, p=0.851). Corresponding number at 1 year visit was 1.2±2 in AT and 2.8±1.8 in A (p=0.001). The incidence of a hypertensive phase was 18.7% in AT and 35.5% in A (p=0.05). HP resolved in only 30% of eyes. The criteria for HP resolution were fulfilled in 9 eyes (30%). There was no difference in the rate of resolution of the hypertensive phase between AT and A (33.3% and 28.5%, respectively, p=0.67). Conclusion: Ahmed glaucoma valve implant with same session trabectome surgery significantly decreased the rate of the hypertensive phase and postoperative IOP as well as the number of glaucoma medications.
- 5 February 2018
- Published by MDPI AG in Preprints.org
Open AccessImpact of Same-Session Trabectome Surgery on Ahmed Glaucoma Valve Outcomes
Purpose: To evaluate the efficacy and survival rates of same session ab interno trabeculectomy with the trabectome and Ahmed glaucoma valve implant (AT) in comparison to the Ahmed glaucoma valve alone (A). Method: A total of 107 eyes undergoing primary glaucoma surgery were enrolled in this retrospective comparative case series, including 48 eyes which underwent AT and 59 eyes which received A alone. Participants were identified using the procedural terminology codes, and their medical records were reviewed. The primary outcome measure was surgical success, defined as intraocular pressure (IOP) > 5 mmHg, ≤ 21 mmHg, and IOP reduction ≥ 20% from baseline at two consecutive visits after three months, no reoperation for glaucoma. Secondary outcome measures were IOP, the number of glaucoma medications, incidence of a hypertensive phase, and best corrected visual acuity (BCVA). Results: The cumulative probability of success at one year was 70% in AT, and 65% in A (p=0.85). IOP decreased significantly from 26.6 ± 10.1 mmHg at baseline to 14.7 ± 3.3 mmHg at the final follow-up in AT (p= 0.001). The corresponding numbers for A were 28.8 ± 10.2 and 16.7 ± 4.9, respectively (p= 0.001). The final IOP was significantly lower in AT (p= 0.022). The number of medications at baseline was comparable in both groups (2.6 ± 1.2 in AT and 2.5 ± 1.3 in A, p=0.851). Corresponding number at 1 year visit was 1.2±2 in AT and 2.8±1.8 in A (p=0.001). The incidence of a hypertensive phase was 18.7% in AT and 35.5% in A (p=0.05). HP resolved in only 30% of eyes. The criteria for HP resolution were fulfilled in 9 eyes (30%). There was no difference in the rate of resolution of the hypertensive phase between AT and A (33.3% and 28.5%, respectively, p=0.67). Conclusion: Ahmed glaucoma valve implant with same session trabectome surgery significantly decreased the rate of the hypertensive phase and postoperative IOP as well as the number of glaucoma medications.