Simulation of the Effect of Flexible and Rigid Plate Designs on Murine Fracture Healing
Open Access
- 1 January 2011
- journal article
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 6 (4) , 311-321
Abstract
Although several histological studies in mice have examined healing of fractures secured with bone plates, no data are available at present on the mechanical response of fractured bone or callus tissue. Here, we simulated the healing response of fractures secured with rigid and flexible bone plate-designs. Using finite element methods, we simulated the maximum principal strain, stress, and strain energy density in the fractured region of mouse femurs under three loading conditions. In the rigid plate-design, the strain energy density increased when compression and bending were loaded and decreased when torsion was loaded. In the flexible plate-design, the strain energy density increased under all loading conditions. Since an increase in the strain energy density indicates an increase in mechanical stimulation, the simulation suggests that the flexible plate design may stimulate bone growth more than the rigid plate design. A favorable bone plate design must be stiff enough to avoid dislocation but flexible enough to provide mechanical stimulation.Keywords
This publication has 30 references indexed in Scilit:
- Initial fixation of a finite element model of an AI-Hip cementless stem evaluated by micromotion and stressJournal of Orthopaedic Science, 2010
- Fixation compliance in a mouse osteotomy model induces two different processes of bone healing but does not lead to delayed unionJournal of Biomechanics, 2009
- A CT-Based High-Order Finite Element Analysis of the Human Proximal Femur Compared to In-vitro ExperimentsJournal of Biomechanical Engineering, 2006
- Assessment of the fixation stiffness of some femoral stems of different designsClinical Biomechanics, 2006
- Finite element models predict in vitro vertebral body compressive strength better than quantitative computed tomographyBone, 2003
- The influence of mechanical stimulus on the pattern of tissue differentiation in a long bone fracture — an FEM studyJournal of Biomechanics, 2000
- Load transfer analysis of the distal radius from in-vivo high-resolution CT-imagingJournal of Biomechanics, 1999
- The role of an effective isotropic tissue modulus in the elastic properties of cancellous boneJournal of Biomechanics, 1999
- Effects of Fit and Bonding Characteristics of Femoral Stems on Adaptive Bone RemodelingJournal of Biomechanical Engineering, 1994
- Adaptive bone-remodeling theory applied to prosthetic-design analysisJournal of Biomechanics, 1987