Corrosion of 3D-Printed Orthopaedic Implant Materials
- 15 August 2018
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 47 (1) , 162-173
Abstract
3D-printing technologies such as electron beam melting (EBM) have allowed for patient-specific orthopaedic implants, however differences generated from the fabrication process may alter the corrosion properties of Ti6Al4V implants. This study evaluated the corrosion characteristics of EBM-fabricated Ti6Al4V, alongside any linked microstructural and surface changes. EBM-fabricated Ti6Al4V and wrought Ti6Al4V specimens (n = 10 per group) underwent microstructural and surface characterisation before and after corrosion testing. Cyclic potentiodynamic polarisation of specimens was conducted in accordance with ASTM Standard F2129-17. The degree of corrosion damage was subsequently assessed via qualitative and quantitative measures. EBM-fabricated Ti6Al4V demonstrated a higher proportion of β phases and greater surface roughness, compared to wrought Ti6Al4V. Significant differences were observed for all corrosion parameters between the two groups. The lower breakdown potentials (Eb) for EBM-fabricated Ti6Al4V (2.035 V), compared to wrought Ti6Al4V (3.667 V), indicate a lower resistance to pitting corrosion. A greater resultant spread, and severity of corrosion damage was noted on wrought Ti6Al4V. An inferior in vitro corrosion resistance was observed for EBM-fabricated Ti6Al4V. Without post-processing, the rougher surface and differences in microstructure are likely to contribute to this. This suggests potential clinical implications upon in vivo implantation, although corrosion measures remain above recommended minimums.Keywords
This publication has 46 references indexed in Scilit:
- Next Generation Orthopaedic Implants by Additive Manufacturing Using Electron Beam MeltingInternational Journal of Biomaterials, 2012
- Evaluation of microstructural development in electron beam melted Ti-6Al-4VMaterials Characterization, 2012
- Evaluation of titanium alloy fabricated using electron beam melting system for dental applicationsJournal of Materials Processing Technology, 2011
- In situ corrosion monitoring of Ti–6Al–4V alloy in H2SO4/HCl mixed solution using electrochemical AFMElectrochimica Acta, 2011
- Mechanical evaluation of porous titanium (Ti6Al4V) structures with electron beam melting (EBM)Journal of the Mechanical Behavior of Biomedical Materials, 2010
- Microstructures and mechanical properties of electron beam-rapid manufactured Ti–6Al–4V biomedical prototypes compared to wrought Ti–6Al–4VMaterials Characterization, 2009
- Dependence of the Critical Pitting Temperature on surface roughnessCorrosion Science, 2003
- Characterization of different materials for corrosion resistance under simulated body fluid conditionsMaterials Characterization, 2002
- Understanding and controlling the bone–implant interfaceBiomaterials, 1999
- Mechanical properties of biomedical titanium alloysMaterials Science and Engineering: A, 1998