Dominic Mah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dominic Mah has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Aamir Raoof Memon
Institute for Health and Sport, Victoria University, Melbourne, Victoria, Australia
1 shared publication - Amy Elizabeth Harwood
Department of Sport and Exercise Sciences, Manchester Metropolitan University, Manchester, UK
1 shared publication Ana Morais Azevedo
Private practice, Lissabon, Portugal
1 shared publication- Ariella Jessica Smith
Department of Orthopaedic Surgery, Hornsby Ku-ring-gai Hospital, Hornsby, NSW, Australia
1 shared publication Benjamin Francis Pfister
Orthopaedic Department Lismore Base Hospital Lismore New South Wales 2480 Australia
1 shared publication- Chao Cao
Department of Medical Oncology, Dana-Farber Cancer Institute, Boston, MA 02215, USA
1 shared publication
Latest Publications
- Open Access
- 30 June 2021
- Published by BMJ in BMJ Open Sport & Exercise Medicine
- Vol. 7 (2) , e001171
Let us introduce ourselves, #WeAreBOSEM
- 30 June 2021
- Published by BMJ in BMJ Open Sport & Exercise Medicine
- Vol. 7 (2) , e001171
Open AccessLet us introduce ourselves, #WeAreBOSEM
- 20 May 2021
- Published by Wiley in Anz Journal of Surgery
- Vol. 91 (7-8) , 1369-1375
Increased orthopaedic presentations as a result of COVID‐19‐related social restrictions in a regional setting, despite local and global trends
Background: The coronavirus (COVID‐19) pandemic has affected the utilisation of emergency department (ED) services worldwide. The aim of this study was to assess the impact of COVID‐19‐related public health measures on orthopaedic presentations to a regional Australian hospital.Methods: A case–control study was performed at a regional trauma hospital in New South Wales (NSW), Australia. Data was collected prospectively from patients that required orthopaedic review in the period corresponding to a declaration of a global pandemic to the end of the NSW lockdown, and compared with retrospective data from the corresponding period in 2019. The five‐year average of orthopaedic presentations to ED during the study period were obtained for comparison. The primary outcomes were overall number of presentations, mechanism and anatomical location of injuries, operative versus non‐operative management and disposition.Results: During the study period in 2020, presentations requiring orthopaedic review were significantly more frequent than 2019 (496 vs. 280, p < 0.0001), with more requiring admission in 2020 (p < 0.0001). The absolute number of patients managed operatively was higher (p = 0.0002) and significantly more patients were referred for community follow‐up (p < 0.0001). There was a 20% increase of consults in 2020 compared to the average number of referrals during the same period in the previous five years.Conclusions: Contrary to other published literature, lockdown conditions imposed during the COVID‐19 pandemic resulted in a surprising 77% increase in orthopaedic presentations to this regional Australian hospital. These findings can be used to better direct resources, preparation and staff education in the current and for future pandemics.
- 20 May 2021
- Published by Wiley in Anz Journal of Surgery
- Vol. 91 (7-8) , 1369-1375
Increased orthopaedic presentations as a result of COVID‐19‐related social restrictions in a regional setting, despite local and global trends
Background: The coronavirus (COVID‐19) pandemic has affected the utilisation of emergency department (ED) services worldwide. The aim of this study was to assess the impact of COVID‐19‐related public health measures on orthopaedic presentations to a regional Australian hospital.Methods: A case–control study was performed at a regional trauma hospital in New South Wales (NSW), Australia. Data was collected prospectively from patients that required orthopaedic review in the period corresponding to a declaration of a global pandemic to the end of the NSW lockdown, and compared with retrospective data from the corresponding period in 2019. The five‐year average of orthopaedic presentations to ED during the study period were obtained for comparison. The primary outcomes were overall number of presentations, mechanism and anatomical location of injuries, operative versus non‐operative management and disposition.Results: During the study period in 2020, presentations requiring orthopaedic review were significantly more frequent than 2019 (496 vs. 280, p < 0.0001), with more requiring admission in 2020 (p < 0.0001). The absolute number of patients managed operatively was higher (p = 0.0002) and significantly more patients were referred for community follow‐up (p < 0.0001). There was a 20% increase of consults in 2020 compared to the average number of referrals during the same period in the previous five years.Conclusions: Contrary to other published literature, lockdown conditions imposed during the COVID‐19 pandemic resulted in a surprising 77% increase in orthopaedic presentations to this regional Australian hospital. These findings can be used to better direct resources, preparation and staff education in the current and for future pandemics.
- 1 October 2019
- Published by Elsevier in Journal of Science and Medicine in Sport
- Vol. 22, S93-S94
Case Study: Dupuytren's Contracture in a Young Female Powerlifter
- 1 October 2019
- Published by Elsevier in Journal of Science and Medicine in Sport
- Vol. 22, S93-S94
Case Study: Dupuytren's Contracture in a Young Female Powerlifter
- 23 October 2018
- Published by BMJ in British Journal of Sports Medicine
- Vol. 53 (10) , 607-608
University of Melbourne: combining practice with innovation in the latest completely online Masters of Sports Medicine (continuing professional development series)
Faculty of Medicine, Dentistry & Health Sciences, The University of Melbourne, Melbourne, Australia. Masters of Sports Medicine. Delivered 100% online, the newly released Masters of Sports Medicine at the University of Melbourne targets clinicians looking to develop a successful sports and exercise medicine (SEM) career. Such postgraduate qualifications open doors as an SEM professional with recognised expertise, as well as providing stepping stones towards final-stage specialty training.1–4 Launched in 2018, this is Australia’s latest postgraduate SEM programme. It is designed for medical doctors, physiotherapists and podiatrists worldwide with ≥3 years of sports-relevant clinical experience (table 1), seeking to extend expertise in all areas of SEM including physical activity, community participation and high-performance sport. The programme is directed by Sonya …
- 23 October 2018
- Published by BMJ in British Journal of Sports Medicine
- Vol. 53 (10) , 607-608
University of Melbourne: combining practice with innovation in the latest completely online Masters of Sports Medicine (continuing professional development series)
Faculty of Medicine, Dentistry & Health Sciences, The University of Melbourne, Melbourne, Australia. Masters of Sports Medicine. Delivered 100% online, the newly released Masters of Sports Medicine at the University of Melbourne targets clinicians looking to develop a successful sports and exercise medicine (SEM) career. Such postgraduate qualifications open doors as an SEM professional with recognised expertise, as well as providing stepping stones towards final-stage specialty training.1–4 Launched in 2018, this is Australia’s latest postgraduate SEM programme. It is designed for medical doctors, physiotherapists and podiatrists worldwide with ≥3 years of sports-relevant clinical experience (table 1), seeking to extend expertise in all areas of SEM including physical activity, community participation and high-performance sport. The programme is directed by Sonya …
- 15 August 2018
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 47 (1) , 162-173
Corrosion of 3D-Printed Orthopaedic Implant Materials
3D-printing technologies such as electron beam melting (EBM) have allowed for patient-specific orthopaedic implants, however differences generated from the fabrication process may alter the corrosion properties of Ti6Al4V implants. This study evaluated the corrosion characteristics of EBM-fabricated Ti6Al4V, alongside any linked microstructural and surface changes. EBM-fabricated Ti6Al4V and wrought Ti6Al4V specimens (n = 10 per group) underwent microstructural and surface characterisation before and after corrosion testing. Cyclic potentiodynamic polarisation of specimens was conducted in accordance with ASTM Standard F2129-17. The degree of corrosion damage was subsequently assessed via qualitative and quantitative measures. EBM-fabricated Ti6Al4V demonstrated a higher proportion of β phases and greater surface roughness, compared to wrought Ti6Al4V. Significant differences were observed for all corrosion parameters between the two groups. The lower breakdown potentials (Eb) for EBM-fabricated Ti6Al4V (2.035 V), compared to wrought Ti6Al4V (3.667 V), indicate a lower resistance to pitting corrosion. A greater resultant spread, and severity of corrosion damage was noted on wrought Ti6Al4V. An inferior in vitro corrosion resistance was observed for EBM-fabricated Ti6Al4V. Without post-processing, the rougher surface and differences in microstructure are likely to contribute to this. This suggests potential clinical implications upon in vivo implantation, although corrosion measures remain above recommended minimums.
- 15 August 2018
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 47 (1) , 162-173
Corrosion of 3D-Printed Orthopaedic Implant Materials
3D-printing technologies such as electron beam melting (EBM) have allowed for patient-specific orthopaedic implants, however differences generated from the fabrication process may alter the corrosion properties of Ti6Al4V implants. This study evaluated the corrosion characteristics of EBM-fabricated Ti6Al4V, alongside any linked microstructural and surface changes. EBM-fabricated Ti6Al4V and wrought Ti6Al4V specimens (n = 10 per group) underwent microstructural and surface characterisation before and after corrosion testing. Cyclic potentiodynamic polarisation of specimens was conducted in accordance with ASTM Standard F2129-17. The degree of corrosion damage was subsequently assessed via qualitative and quantitative measures. EBM-fabricated Ti6Al4V demonstrated a higher proportion of β phases and greater surface roughness, compared to wrought Ti6Al4V. Significant differences were observed for all corrosion parameters between the two groups. The lower breakdown potentials (Eb) for EBM-fabricated Ti6Al4V (2.035 V), compared to wrought Ti6Al4V (3.667 V), indicate a lower resistance to pitting corrosion. A greater resultant spread, and severity of corrosion damage was noted on wrought Ti6Al4V. An inferior in vitro corrosion resistance was observed for EBM-fabricated Ti6Al4V. Without post-processing, the rougher surface and differences in microstructure are likely to contribute to this. This suggests potential clinical implications upon in vivo implantation, although corrosion measures remain above recommended minimums.
- 1 December 2015
- Published by Elsevier in Journal of Science and Medicine in Sport
- Vol. 19, e43
Social Media and UNSW Sports Medicine Society: A new face in Sports and Exercise Medicine
- 1 December 2015
- Published by Elsevier in Journal of Science and Medicine in Sport
- Vol. 19, e43
Social Media and UNSW Sports Medicine Society: A new face in Sports and Exercise Medicine