Sensitivity Analysis of Factors Affecting the Calibration of Heat-Flow-Meter Apparatus
- 31 August 2018
- journal article
- research article
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 47 (4) , 2979-3002
Abstract
The analysis and results of a sensitivity study of four procedural variables on the calibration response of two commercial heat-flow-meter apparatuses in conformance with ASTM Test Method C518, Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus, are presented. The apparatuses ranged in plate size from 305 mm by 305 mm to 610 mm by 610 mm and were calibrated using Standard Reference Materials 1450c, Fibrous Glass Board, and 1453, Expanded Polystyrene Board, issued by the National Institute of Standards and Technology. A major objective of the study is to rank the relative importance of the factors and interactions affecting the calibration of the apparatus. Seventy-six runs were conducted under input conditions that varied the mean temperatures from 17°C to 30°C, temperature differences from 17 K to 30 K, heat flow up or down across the specimen thickness, and different circulation bath temperatures. For each apparatus and SRM, the experiment followed a full factorial design for the four factors and included three interspatial replicates to assess for temporal drift. The study revealed that mean temperature and heat flow direction were the two most important test method factors affecting the calibration of both apparatuses. Although the temperature effect was the same for both apparatuses, the heat flow direction effect was found to be instrument dependent. The study also found that the calibration factor for each apparatus was affected by the reference material utilized for calibration. Empirically derived predictive models for each apparatus SRM combination are presented covering the experimental region defined by the input test conditions.Keywords
This publication has 19 references indexed in Scilit:
- Calibration of a Heat Flow Meter ApparatusJournal of Thermal Insulation and Building Envelopes, 1994
- Discussion of Heat Flow Meter Apparatus Calibration and Traceability Issues for Thermal Conductivity MeasurementsJournal of Thermal Insulation and Building Envelopes, 1994
- Control Stability of a Heat-Flow-Meter ApparatusJournal of Thermal Insulation and Building Envelopes, 1994
- A Workshop on Measurement Errors and Methods of Calibration of a Heat Flow Meter ApparatusJournal of Thermal Insulation and Building Envelopes, 1994
- Evaluation of a commercial, computer-operated heat flow meter apparatusReview of Scientific Instruments, 1993
- Intra-Laboratory Comparison of a Line-Heat-Source Guarded Hot Plate and Heat-Flow-Meter Apparatus1991
- Historical Development of Large Heat Flow Meter Apparatus for Measurements of Thermal Resistance of Insulations1987
- NVLAP and the Thermal Insulation Proficiency Testing ProgramJournal of Thermal Insulation, 1985
- Implementation of a New Quality-Control Instrument for Thermal Measurements of a Low-Density Building Insulation1980
- The Calibration of Heat Flow Meters1980