Robert R. Zarr
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Robert R. Zarr has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
William C. Thomas
Virginia Polytechnic Institute and State University Blacksburg, VA 24061, USA
2 shared publicationsAlain Koenen
Laboratoire National de Métrologie et d’essais
1 shared publication- Bruno Hay
Laboratoire National de Métrologie et d'Essais (LNE), Paris, France
1 shared publication David. L. McElroy
Oak Ridge National Laboratory 3 , 1 Bethel Valley Rd., Oak Ridge, TN 37830 , (retired)
1 shared publicationJames J. Filliben
Information Technology Laboratory, National Institute of Standards and Technology 3 , 100 Bureau Dr., MS 8980, Gaithersburg, MD 20899-8980
1 shared publication- N. Alan Heckert
Information Technology Laboratory (Statistical Engineering Division), National Institute of Standards and Technology, Gaithersburg, USA
1 shared publication
Latest Publications
- 5 March 2019
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 47 (6) , 4567-4578
Historical Review of the Metered Section Area for the Guarded-Hot-Plate Method
Results of an extensive literature review and investigation of the metered section area for the guarded-hot-plate method, standardized as ASTM C177, Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus, are presented. The guarded-hot-plate apparatus is a primary linear-heat-flow method generally used to determine the thermal conductivity of insulating and building materials. The review examined technical publications from 1885 to 1990 and identified 31 papers of interest. Historical versions of ASTM C177 were also researched as well as test methods from other standard development organizations. The investigation revealed that, over the past 100 years, researchers have independently developed two main approaches for the computation of the metered section area. An assessment of the calculation techniques is presented for round plates with diameters from 250 to 1,000 mm, a guard-to-meter aspect ratio of 2, and guard gap widths of 1–4 mm. The gap effects are not negligible because large gaps (4 mm) on small plates (250 mm) can lead to errors of 10 % or more on the computation of the metered section area, ultimately affecting the uncertainty of the test results of the guarded-hot-plate method. The results of this study are applicable to other thermal conductivity test methods that employ a primary thermal guard to promote 1-D heat flow.
- 5 March 2019
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 47 (6) , 4567-4578
Historical Review of the Metered Section Area for the Guarded-Hot-Plate Method
Results of an extensive literature review and investigation of the metered section area for the guarded-hot-plate method, standardized as ASTM C177, Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus, are presented. The guarded-hot-plate apparatus is a primary linear-heat-flow method generally used to determine the thermal conductivity of insulating and building materials. The review examined technical publications from 1885 to 1990 and identified 31 papers of interest. Historical versions of ASTM C177 were also researched as well as test methods from other standard development organizations. The investigation revealed that, over the past 100 years, researchers have independently developed two main approaches for the computation of the metered section area. An assessment of the calculation techniques is presented for round plates with diameters from 250 to 1,000 mm, a guard-to-meter aspect ratio of 2, and guard gap widths of 1–4 mm. The gap effects are not negligible because large gaps (4 mm) on small plates (250 mm) can lead to errors of 10 % or more on the computation of the metered section area, ultimately affecting the uncertainty of the test results of the guarded-hot-plate method. The results of this study are applicable to other thermal conductivity test methods that employ a primary thermal guard to promote 1-D heat flow.
- 31 August 2018
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 47 (4) , 2979-3002
Sensitivity Analysis of Factors Affecting the Calibration of Heat-Flow-Meter Apparatus
The analysis and results of a sensitivity study of four procedural variables on the calibration response of two commercial heat-flow-meter apparatuses in conformance with ASTM Test Method C518, Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus, are presented. The apparatuses ranged in plate size from 305 mm by 305 mm to 610 mm by 610 mm and were calibrated using Standard Reference Materials 1450c, Fibrous Glass Board, and 1453, Expanded Polystyrene Board, issued by the National Institute of Standards and Technology. A major objective of the study is to rank the relative importance of the factors and interactions affecting the calibration of the apparatus. Seventy-six runs were conducted under input conditions that varied the mean temperatures from 17°C to 30°C, temperature differences from 17 K to 30 K, heat flow up or down across the specimen thickness, and different circulation bath temperatures. For each apparatus and SRM, the experiment followed a full factorial design for the four factors and included three interspatial replicates to assess for temporal drift. The study revealed that mean temperature and heat flow direction were the two most important test method factors affecting the calibration of both apparatuses. Although the temperature effect was the same for both apparatuses, the heat flow direction effect was found to be instrument dependent. The study also found that the calibration factor for each apparatus was affected by the reference material utilized for calibration. Empirically derived predictive models for each apparatus SRM combination are presented covering the experimental region defined by the input test conditions.
- 31 August 2018
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 47 (4) , 2979-3002
Sensitivity Analysis of Factors Affecting the Calibration of Heat-Flow-Meter Apparatus
The analysis and results of a sensitivity study of four procedural variables on the calibration response of two commercial heat-flow-meter apparatuses in conformance with ASTM Test Method C518, Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus, are presented. The apparatuses ranged in plate size from 305 mm by 305 mm to 610 mm by 610 mm and were calibrated using Standard Reference Materials 1450c, Fibrous Glass Board, and 1453, Expanded Polystyrene Board, issued by the National Institute of Standards and Technology. A major objective of the study is to rank the relative importance of the factors and interactions affecting the calibration of the apparatus. Seventy-six runs were conducted under input conditions that varied the mean temperatures from 17°C to 30°C, temperature differences from 17 K to 30 K, heat flow up or down across the specimen thickness, and different circulation bath temperatures. For each apparatus and SRM, the experiment followed a full factorial design for the four factors and included three interspatial replicates to assess for temporal drift. The study revealed that mean temperature and heat flow direction were the two most important test method factors affecting the calibration of both apparatuses. Although the temperature effect was the same for both apparatuses, the heat flow direction effect was found to be instrument dependent. The study also found that the calibration factor for each apparatus was affected by the reference material utilized for calibration. Empirically derived predictive models for each apparatus SRM combination are presented covering the experimental region defined by the input test conditions.
- 8 January 2018
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 123, 1-24
Transient Thermal Response of a Guarded-Hot-Plate Apparatus for Operation Over an Extended Temperature Range
A mathematical model is presented for a new-generation guarded-hot-plate apparatus to measure the thermal conductivity of insulation materials. This apparatus will be used to provide standard reference materials for greater ranges of temperature and pressure than have been previously available. The apparatus requires precise control of 16 interacting heated components to achieve the steady temperature and one-dimensional heat-transfer conditions specified in standardized test methods. Achieving these criteria requires deriving gain settings for the 16 proportional-integral-derivative (PID) controllers, comprising potentially 48 parameters. Traditional tuning procedures based on trial-and-error operation of the actual apparatus impose unacceptably lengthy test times and expense. A primary objective of the present investigation is to describe and confirm the incremental control algorithm for this application and determine satisfactory gain settings using a mathematical model that simulates in seconds test runs that would require days to complete using the apparatus. The first of two steps to achieve precise temperature control is to create and validate a model that accounts for heating rates in the various components and interactions with their surroundings. The next step is to simulate dynamic performance and control with the model and determine settings for the PID controllers. A key criterion in deriving the model is to account for effects that significantly impact thermal conductivity measurements while maintaining a tractable model that meets the simulation time constraint. The mathematical model presented here demonstrates how an intricate apparatus can be represented by many interconnected aggregated-capacity masses to depict overall thermal response for control simulations. The major assemblies are the hot plate with four subcomponents, two cold plates with three subcomponents each, and two edge guards with three subcomponents each. Using symmetry about the hot plate, the number of components in the simulation model is reduced to 12 or 15, depending on the mode of operation for the apparatus. Configurations of the main components with embedded heating elements were carefully designed earlier using detailed finite-element analyses to give essentially isothermal surfaces and one-dimensional heat flow through test specimens. It is not tractable, or perhaps justified, to extend these prior analyses to simulate the controlled transient responses of the apparatus. The earlier design criterion does, however, support the aggregated-capacity simplification implemented in the present thermal model. The governing equations follow from dynamic energy balances on components with controlled heating elements and additional intermediate (“floating”) components. Thermal bridges comprise conduction paths, with and without surface convection and radiation, between components and fixed-temperature “heat sinks.” An implicit finite-difference numerical method was used to solve the resulting system of first-order differential equations. The mathematical model was initially validated using measurement data from test runs where a step change in heating rate was applied to single elements in turn, and component temperatures were recorded up to a nearly steady condition. Thermocouples and standard platinum resistance thermometers were used to measure temperatures, and thermopiles were used to measure temperature differences. Next, extensive simulations were conducted with the mathematical model to estimate suitable gain settings for the various controllers. The criteria were tight temperature control after reaching set points and acceptable times to achieve quasi-steady-state operation. Comparisons between measurements and predicted temperatures for heated components are presented. The results show that the model incorporating the above simplifying approximations is satisfactory for components comprising the hot-plate and cold-plate assemblies. For the edge guards, however, the conventional aggregated-capacity criteria are not as fully satisfied because of their configuration. Temperature variations in the edge guards, fortunately, have a lesser effect on the accuracy of the thermal conductivity measurements. Therefore, the thermal response model is deemed satisfactory for simulating PID feedback to investigate “closed-loop” control of the apparatus, thus meeting the primary objective.
- 8 January 2018
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 123, 1-24
Transient Thermal Response of a Guarded-Hot-Plate Apparatus for Operation Over an Extended Temperature Range
A mathematical model is presented for a new-generation guarded-hot-plate apparatus to measure the thermal conductivity of insulation materials. This apparatus will be used to provide standard reference materials for greater ranges of temperature and pressure than have been previously available. The apparatus requires precise control of 16 interacting heated components to achieve the steady temperature and one-dimensional heat-transfer conditions specified in standardized test methods. Achieving these criteria requires deriving gain settings for the 16 proportional-integral-derivative (PID) controllers, comprising potentially 48 parameters. Traditional tuning procedures based on trial-and-error operation of the actual apparatus impose unacceptably lengthy test times and expense. A primary objective of the present investigation is to describe and confirm the incremental control algorithm for this application and determine satisfactory gain settings using a mathematical model that simulates in seconds test runs that would require days to complete using the apparatus. The first of two steps to achieve precise temperature control is to create and validate a model that accounts for heating rates in the various components and interactions with their surroundings. The next step is to simulate dynamic performance and control with the model and determine settings for the PID controllers. A key criterion in deriving the model is to account for effects that significantly impact thermal conductivity measurements while maintaining a tractable model that meets the simulation time constraint. The mathematical model presented here demonstrates how an intricate apparatus can be represented by many interconnected aggregated-capacity masses to depict overall thermal response for control simulations. The major assemblies are the hot plate with four subcomponents, two cold plates with three subcomponents each, and two edge guards with three subcomponents each. Using symmetry about the hot plate, the number of components in the simulation model is reduced to 12 or 15, depending on the mode of operation for the apparatus. Configurations of the main components with embedded heating elements were carefully designed earlier using detailed finite-element analyses to give essentially isothermal surfaces and one-dimensional heat flow through test specimens. It is not tractable, or perhaps justified, to extend these prior analyses to simulate the controlled transient responses of the apparatus. The earlier design criterion does, however, support the aggregated-capacity simplification implemented in the present thermal model. The governing equations follow from dynamic energy balances on components with controlled heating elements and additional intermediate (“floating”) components. Thermal bridges comprise conduction paths, with and without surface convection and radiation, between components and fixed-temperature “heat sinks.” An implicit finite-difference numerical method was used to solve the resulting system of first-order differential equations. The mathematical model was initially validated using measurement data from test runs where a step change in heating rate was applied to single elements in turn, and component temperatures were recorded up to a nearly steady condition. Thermocouples and standard platinum resistance thermometers were used to measure temperatures, and thermopiles were used to measure temperature differences. Next, extensive simulations were conducted with the mathematical model to estimate suitable gain settings for the various controllers. The criteria were tight temperature control after reaching set points and acceptable times to achieve quasi-steady-state operation. Comparisons between measurements and predicted temperatures for heated components are presented. The results show that the model incorporating the above simplifying approximations is satisfactory for components comprising the hot-plate and cold-plate assemblies. For the edge guards, however, the conventional aggregated-capacity criteria are not as fully satisfied because of their configuration. Temperature variations in the edge guards, fortunately, have a lesser effect on the accuracy of the thermal conductivity measurements. Therefore, the thermal response model is deemed satisfactory for simulating PID feedback to investigate “closed-loop” control of the apparatus, thus meeting the primary objective.
- 20 January 2017
- Published by IOP Publishing in Metrologia
- Vol. 54 (1) , 113-128
Collaborative guarded-hot-plate tests between the Laboratoire national de métrologie et d’essais and the National Institute of Standards and Technology
A collaborative study to compare the long-term measurement performance between guarded-hot-plate facilities at the Laboratoire national de métrologie et d’essais (LNE) in France and the National Institute of Standards and Technology (NIST) in the United States is presented. Thermal conductivity data were compiled from three international comparisons organized from 1997 to 2014. Measurements were conducted in accordance with standardized test methods (ISO 8302 or ASTM C 177) over a temperature range from 280 K to 320 K. Nine thermal insulating materials (either mineral fiber or expanded polystyrene) were examined covering broad ranges of bulk densities (13 kg · m −3 –200 kg · m −3 ) and thicknesses (13 mm–70 mm). A different set of specimens was utilized for each comparison. Results of this study indicate that, over a 17 year interval, the majority of test data from LNE and NIST agreed to within ±1.0%, or less, for mineral fiber materials and to within ±0.5%, or less, for expanded polystyrene. The long-term variability limit of 1% between the two laboratories is in good agreement with their current measurement uncertainties. Regression coefficients and their standard uncertainties for a straight-line model relating thermal conductivity to temperature from 280 K to 320 K were computed by material and laboratory. Graphical analysis of the data and corresponding fits exhibit consistent behavior by material type between the two laboratories. Sources of measurement variability are addressed.
- 20 January 2017
- Published by IOP Publishing in Metrologia
- Vol. 54 (1) , 113-128
Collaborative guarded-hot-plate tests between the Laboratoire national de métrologie et d’essais and the National Institute of Standards and Technology
A collaborative study to compare the long-term measurement performance between guarded-hot-plate facilities at the Laboratoire national de métrologie et d’essais (LNE) in France and the National Institute of Standards and Technology (NIST) in the United States is presented. Thermal conductivity data were compiled from three international comparisons organized from 1997 to 2014. Measurements were conducted in accordance with standardized test methods (ISO 8302 or ASTM C 177) over a temperature range from 280 K to 320 K. Nine thermal insulating materials (either mineral fiber or expanded polystyrene) were examined covering broad ranges of bulk densities (13 kg · m −3 –200 kg · m −3 ) and thicknesses (13 mm–70 mm). A different set of specimens was utilized for each comparison. Results of this study indicate that, over a 17 year interval, the majority of test data from LNE and NIST agreed to within ±1.0%, or less, for mineral fiber materials and to within ±0.5%, or less, for expanded polystyrene. The long-term variability limit of 1% between the two laboratories is in good agreement with their current measurement uncertainties. Regression coefficients and their standard uncertainties for a straight-line model relating thermal conductivity to temperature from 280 K to 320 K were computed by material and laboratory. Graphical analysis of the data and corresponding fits exhibit consistent behavior by material type between the two laboratories. Sources of measurement variability are addressed.
- 1 August 2014
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 119, 296-370
Retrospective Analysis of NIST Standard Reference Material 1450, Fibrous Glass Board, for Thermal Insulation Measurements
Thermal conductivity data acquired previously for the establishment of Standard Reference Material (SRM) 1450, Fibrous Glass Board, as well as subsequent renewals 1450a, 1450b, 1450c, and 1450d, are re-analyzed collectively and as individual data sets. Additional data sets for proto-1450 material lots are also included in the analysis. The data cover 36 years of activity by the National Institute of Standards and Technology (NIST) in developing and providing thermal insulation SRMs, specifically high-density molded fibrous-glass board, to the public. Collectively, the data sets cover two nominal thicknesses of 13 mm and 25 mm, bulk densities from 60 kg·m(-3) to 180 kg·m(-3), and mean temperatures from 100 K to 340 K. The analysis repetitively fits six models to the individual data sets. The most general form of the nested set of multilinear models used is given in the following equation: [Formula: see text]where λ(ρ,T) is the predicted thermal conductivity (W·m(-1)·K(-1)), ρ is the bulk density (kg·m(-3)), T is the mean temperature (K) and ai (for i = 1, 2, … 6) are the regression coefficients. The least squares fit results for each model across all data sets are analyzed using both graphical and analytic techniques. The prevailing generic model for the majority of data sets is the bilinear model in ρ and T. [Formula: see text] One data set supports the inclusion of a cubic temperature term and two data sets with low-temperature data support the inclusion of an exponential term in T to improve the model predictions. Physical interpretations of the model function terms are described. Recommendations for future renewals of SRM 1450 are provided. An Addendum provides historical background on the origin of this SRM and the influence of the SRM on external measurement programs.
- 1 August 2014
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 119, 296-370
Retrospective Analysis of NIST Standard Reference Material 1450, Fibrous Glass Board, for Thermal Insulation Measurements
Thermal conductivity data acquired previously for the establishment of Standard Reference Material (SRM) 1450, Fibrous Glass Board, as well as subsequent renewals 1450a, 1450b, 1450c, and 1450d, are re-analyzed collectively and as individual data sets. Additional data sets for proto-1450 material lots are also included in the analysis. The data cover 36 years of activity by the National Institute of Standards and Technology (NIST) in developing and providing thermal insulation SRMs, specifically high-density molded fibrous-glass board, to the public. Collectively, the data sets cover two nominal thicknesses of 13 mm and 25 mm, bulk densities from 60 kg·m(-3) to 180 kg·m(-3), and mean temperatures from 100 K to 340 K. The analysis repetitively fits six models to the individual data sets. The most general form of the nested set of multilinear models used is given in the following equation: [Formula: see text]where λ(ρ,T) is the predicted thermal conductivity (W·m(-1)·K(-1)), ρ is the bulk density (kg·m(-3)), T is the mean temperature (K) and ai (for i = 1, 2, … 6) are the regression coefficients. The least squares fit results for each model across all data sets are analyzed using both graphical and analytic techniques. The prevailing generic model for the majority of data sets is the bilinear model in ρ and T. [Formula: see text] One data set supports the inclusion of a cubic temperature term and two data sets with low-temperature data support the inclusion of an exponential term in T to improve the model predictions. Physical interpretations of the model function terms are described. Recommendations for future renewals of SRM 1450 are provided. An Addendum provides historical background on the origin of this SRM and the influence of the SRM on external measurement programs.
- 4 March 2011
- Published by Elsevier in ISA Transactions
- Vol. 50 (3) , 504-512
Thermal response simulation for tuning PID controllers in a 1016 mm guarded hot plate apparatus
- 4 March 2011
- Published by Elsevier in ISA Transactions
- Vol. 50 (3) , 504-512
Thermal response simulation for tuning PID controllers in a 1016 mm guarded hot plate apparatus
- Open Access
- 1 January 2010
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 115 (1) , 23-59
Assessment of uncertainties for the NIST 1016 mm guarded-hot-plate apparatus: Extended analysis for low-density fibrous-glass thermal insulation
An assessment of uncertainties for the National Institute of Standards and Technology (NIST) 1016 mm Guarded-Hot-Plate apparatus is presented. The uncertainties are reported in a format consistent with current NIST policy on the expression of measurement uncertainty. The report describes a procedure for determination of component uncertainties for thermal conductivity and thermal resistance for the apparatus under operation in either the double-sided or single-sided mode of operation. An extensive example for computation of uncertainties for the single-sided mode of operation is provided for a low-density fibrous-glass blanket thermal insulation. For this material, the relative expanded uncertainty for thermal resistance increases from 1 % for a thickness of 25.4 mm to 3 % for a thickness of 228.6 mm. Although these uncertainties have been developed for a particular insulation material, the procedure and, to a lesser extent, the results are applicable to other insulation materials measured at a mean temperature close to 297 K (23.9 °C, 75 °F). The analysis identifies dominant components of uncertainty and, thus, potential areas for future improvement in the measurement process. For the NIST 1016 mm Guarded-Hot-Plate apparatus, considerable improvement, especially at higher values of thermal resistance, may be realized by developing better control strategies for guarding that include better measurement techniques for the guard gap thermopile voltage and the temperature sensors.
- 1 January 2010
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 115 (1) , 23-59
Open AccessAssessment of uncertainties for the NIST 1016 mm guarded-hot-plate apparatus: Extended analysis for low-density fibrous-glass thermal insulation
An assessment of uncertainties for the National Institute of Standards and Technology (NIST) 1016 mm Guarded-Hot-Plate apparatus is presented. The uncertainties are reported in a format consistent with current NIST policy on the expression of measurement uncertainty. The report describes a procedure for determination of component uncertainties for thermal conductivity and thermal resistance for the apparatus under operation in either the double-sided or single-sided mode of operation. An extensive example for computation of uncertainties for the single-sided mode of operation is provided for a low-density fibrous-glass blanket thermal insulation. For this material, the relative expanded uncertainty for thermal resistance increases from 1 % for a thickness of 25.4 mm to 3 % for a thickness of 228.6 mm. Although these uncertainties have been developed for a particular insulation material, the procedure and, to a lesser extent, the results are applicable to other insulation materials measured at a mean temperature close to 297 K (23.9 °C, 75 °F). The analysis identifies dominant components of uncertainty and, thus, potential areas for future improvement in the measurement process. For the NIST 1016 mm Guarded-Hot-Plate apparatus, considerable improvement, especially at higher values of thermal resistance, may be realized by developing better control strategies for guarding that include better measurement techniques for the guard gap thermopile voltage and the temperature sensors.