Accurate Monte Carlo simulation and image reconstruction for Compton cameras
Author:
- 15 May 2026
- journal article
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (3)
Abstract
Objective. The expanding applications of Compton cameras in biomedical imaging demand precise simulation and reconstruction methods that incorporate realistic physics to optimize performance. To address this need, this study develops an integrated computational framework that combines a Geant4-based Monte Carlo simulation with a dedicated image reconstruction algorithm. Approach. Compared with previous approaches, this framework accurately models inter-pixel energy deposition crosstalk and depth of interaction in Monte Carlo simulation, while also accounting for multiple Compton scattering. In addition, it incorporates accurate models into the system matrix calculation within the list-mode maximum-likelihood expectation-maximization image reconstruction algorithm, including the Compton scattering cross section, the spatial resolution of both the scatterer and absorber detectors, and Doppler broadening effects. Main Results. The framework was validated through simulations of a proposed medical Compton camera design employing a silicon scatterer and a cadmium zinc telluride absorber. Compared with conventional simplified models, the proposed accurate system matrix model yields a marked improvement in reconstruction quality across diverse source geometries, including ideal point, planar, and line sources, as well as hot sources with a uniform background. Significance. This work establishes a high-fidelity framework that enables both physically realistic simulation and quantitatively accurate image reconstruction for Compton cameras. By rigorously validating the model's advantage across multiple source types, it provides an essential tool for advancing the design, optimization, and practical application of Compton imaging systems in biomedical imaging.Keywords
Funding Information
- National Natural Science Foundation of China (11905011)
- National Natural Science Foundation of China (12375157)
This publication has 56 references indexed in Scilit:
- Simultaneous fluorescence and Compton scattering computed tomography based on linear polarization X-rayNuclear Science and Techniques, 2024
- A Monte Carlo simulation method for polarized gamma-ray nuclear resonance fluorescenceNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2023
- Compton imaging for medical applicationsRadiological Physics and Technology, 2022
- A portable Si/CdTe Compton camera and its applications to the visualization of radioactive substancesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015
- MEGAlib – The Medium Energy Gamma-ray Astronomy LibraryNew Astronomy Reviews, 2006
- Geant4—a simulation toolkitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- A Compton camera for nuclear medicine applications using 113mIn1Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999
- Hartree-Fock Compton profiles for the elementsAtomic Data and Nuclear Data Tables, 1975
- A proposed γ cameraNature, 1974
- A telescope for soft gamma ray astronomyNuclear Instruments and Methods, 1973