Compton imaging for medical applications
- 22 July 2022
- journal article
- review article
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 15 (3) , 187-205
Abstract
Compton imaging exploits inelastic scattering, known as Compton scattering, using a Compton camera consisting of a scatterer detector in the front layer and an absorber detector in the back layer. This method was developed for astronomy, and in recent years, research and development for environmental and medical applications has been actively conducted. Compton imaging can discriminate gamma rays over a wide energy range from several hundred keV to several MeV. Therefore, it is expected to be applied to the simultaneous imaging of multiple nuclides in nuclear medicine and prompt gamma ray imaging for range verification in particle therapy. In addition, multiple gamma coincidence imaging is expected to be realized, which allows the source position to be determined from a single coincidence event using nuclides that emit multiple gamma rays simultaneously, such as nuclides that emit a single gamma ray simultaneously with positron decay. This review introduces various efforts toward the practical application of Compton imaging in the medical field, including in vivo studies, and discusses its prospects.Keywords
Funding Information
- Japan Society for the Promotion of Science (21K19936, 20H05667, 20K12683)
- Nakatani Foundation for Advancement of Measuring Technologies in Biomedical Engineering
- Konica Minolta Imaging Science Foundation
This publication has 188 references indexed in Scilit:
- Therapeutic Efficacy of C-Kit-Targeted Radioimmunotherapy Using 90Y-Labeled Anti-C-Kit Antibodies in a Mouse Model of Small Cell Lung CancerPLOS ONE, 2013
- Evaluation of a stochastic reconstruction algorithm for use in Compton camera imaging and beam range verification from secondary gamma emission during proton therapyPhysics in Medicine & Biology, 2012
- Prompt gamma detection for range verification in proton therapyCurrent Applied Physics, 2012
- Performance of 8$\,\times\,$8 Pixel LaBr$_{3}$:Ce and Gd$_{2}$SiO$_{5}$:Ce Scintillator Arrays Coupled to a 64-Channel Multi-Anode PMTIEEE Transactions on Nuclear Science, 2009
- Multiple molecular simultaneous imaging in a live mouse using semiconductor Compton cameraJournal of Analytical Atomic Spectrometry, 2008
- Representation of photon limited data in emission tomography using origin ensemblesPhysics in Medicine & Biology, 2008
- Input files with ORNL—mathematical phantoms of the human body for MCNP-4BComputer Physics Communications, 2007
- A factorization method for the 3D X-ray transformInverse Problems, 1995
- Gamma-radiation imaging system based on the Compton effectProceedings of the Institution of Electrical Engineers, 1977
- A telescope for soft gamma ray astronomyNuclear Instruments and Methods, 1973