Application of GEANT4 to the Simulation of High Energy-Resolution Microcalorimeter Detectors
Authors:
- Michael W. RabinMRMichael W. Rabin
- James A. BeallJBJames A. Beall
- William B. DorieseWDWilliam B. Doriese
- Gene C. HiltonGHGene C. Hilton
- Robert D. HoranskyRHRobert D. Horansky
- Kent D. IrwinKIKent D. Irwin
- Joel N. UllomJUJoel N. Ullom
- 18 August 2009
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 56 (4) , 2294-2298
Abstract
GEANT4 is a versatile Monte Carlo code for simulating the interactions of radiation with matter. GEANT4 has proven to be an effective toolkit for the simulation of a wide variety of detectors. We are interested in the application of GEANT4 to a new type of sensor technology being developed for X-ray and gamma-ray measurements. Microcalorimeter detectors based on transition-edge sensors coupled to bulk absorbers are an emerging technology for hard X-ray and soft gamma-ray measurements with unprecedented energy resolution. In this work, we assess the ability of the GEANT4 electromagnetic physics package to reproduce measured microcalorimeter data. We also use the simulations to explore the design space of absorber materials and cryostat design.Keywords
This publication has 11 references indexed in Scilit:
- Toward a 256-Pixel Array of Gamma-Ray Microcalorimeters for Nuclear-Materials AnalysisJournal of Low Temperature Physics, 2008
- Nuclear diagnostics with cryogenic spectrometersNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- Superconducting absorbers for use in ultra-high resolution gamma-ray spectrometers based on low temperature microcalorimeter arraysNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- Multiplexed microcalorimeter arrays for precision measurements from microwave to gamma-ray wavelengthsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- Array-compatible transition-edge sensor microcalorimeter γ-ray detector with 42eV energy resolution at 103keVApplied Physics Letters, 2006
- The dynamic range of ultra-high-resolution cryogenic gamma-ray spectrometersNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2006
- The GEANT low energy Compton scattering (GLECS) package for use in simulating advanced Compton telescopesNew Astronomy Reviews, 2004
- Geant4—a simulation toolkitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- High-resolution operation of frequency-multiplexed transition-edge photon sensorsApplied Physics Letters, 2002
- WIDTHS OF THE ATOMIC K–N7 LEVELSAtomic Data and Nuclear Data Tables, 2001