Correlating the Effect of Dynamic Variability in the Sensor Environment on Sensor Design
Author:
Open Access
- 9 January 2023
- thesis
- Published by Florida International University
Abstract
This dissertation studies the effect of biofluid dynamics on the electrochemical response of a wearable sensor for monitoring of chronic wounds. The research investigates various dynamic in vivo parameters and correlates them with experimentally measured behavior with wound monitoring as a use case. Wearable electrochemical biosensors suffer from several unaddressed challenges, like stability and sensitivity, that need to be resolved for obtaining accurate data. One of the major challenges in the use of these sensors is continuous variation in biofluid composition. Wound healing is a dynamic process with wound composition changing continuously. This dissertation investigates the effects of several in vivo biochemical and environmental parameters on the sensor response to establish actionable correlations. Real-time assessment of wound healing was carried out through longitudinal monitoring of uric acid and other wound fluid characteristics. A textile sensor was designed using a simple fabrication approach combining conductive inks with a polymeric substrate, for conformal contact with the wound bed. A −1 cm−2, establishing the applicability of the sensor for measurements in the physiologically relevant range. The sensor was also found to be stable for a period of 3 days when subjected to physiological and elevated temperatures (37oC and 40oC) confirming its relevance for long-term monitoring. A direct correlation between sensor response and the dynamic parameters was seen, with the results showing a ~20% deviation from the accurate UA reading. The results confirmed that as a consequence of these parameters temporally changing in the wound environment, the sensor response will be altered. The work develops mathematical models correlating this effect on sensor response to allow for real-time sensor calibration. The clinical validation studies established the feasibility of UA measurement by the developed electrochemical sensor and derive correlations between the wound chronicity and UA levels. The protocols developed in this work for the design, fabrication, and calibration of the sensor to correct for the dynamic in vivo behavior can be extended to any wearable sensor for improved accuracy.Keywords
This publication has 263 references indexed in Scilit:
- Wearable Organic Electrochemical Transistor Patch for Multiplexed Sensing of Calcium and Ammonium Ions from Human PerspirationAdvanced Healthcare Materials, 2019
- Enzyme‐Based Glucose Sensor: From Invasive to Wearable DeviceAdvanced Healthcare Materials, 2018
- A Textile Dressing for Temporal and Dosage Controlled Drug DeliveryAdvanced Functional Materials, 2017
- Flexible Hybrid Electronics: Direct Interfacing of Soft and Hard Electronics for Wearable Health MonitoringAdvanced Functional Materials, 2016
- A Textile‐Based Stretchable Multi‐Ion Potentiometric SensorAdvanced Healthcare Materials, 2016
- Flexible pH‐Sensing Hydrogel Fibers for Epidermal ApplicationsAdvanced Healthcare Materials, 2016
- Dermal Patch with Integrated Flexible Heater for on Demand Drug DeliveryAdvanced Healthcare Materials, 2015
- Contact Lens Sensors in Ocular DiagnosticsAdvanced Healthcare Materials, 2014
- Highly Conductive, Flexible, and Compressible All‐Graphene Passive Electronic Skin for Sensing Human TouchAdvanced Materials, 2014
- Multifunctional Skin‐Like Electronics for Quantitative, Clinical Monitoring of Cutaneous Wound HealingAdvanced Healthcare Materials, 2014