PBPulak Bhushan

Pulak Bhushan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Pulak Bhushan has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    SkinAid: A Wirelessly Powered Smart Dressing Solution for Continuous Wound-Tracking Using Textile-Based Frequency Modulation

    by Dieff Vital, Pulak Bhushan, Pawan Gaire, Khadimul Islam, Shashikant Lahade, Vladimir Pozdin, John L. Volakis, Shekhar Bhansali, Shubhendu Bhardwaj

    In this paper, SkinAid , a battery-free, low-cost, robust, and user-friendly smart bandage for electrochemical monitoring and sensing of chronic wounds is proposed. The working principle of the bandage is based on direct frequency modulation of a tri-electrode electrochemical sensing of wound data. The electronics and biotelemetry links were realized using low-cost manufacturing process of textile embroidery onto fabric substrate. The transmitter was represented by a bedsheet with novel corrugated crossed-dipole made of Elektrisola-7 embroidered onto gauze fabric. An input RF signal of 1 W was transmitted at 462 MHz from the bedsheet to the all-textile bandage featuring a rectifying circuit, a voltage-controlled oscillator (VCO), an electrochemical sensor, and a 915-MHz dipole for re-transmission of the modulated wound data. We demonstrate that for wound fluid emulated by various uric acid concentrations from 0.2 mM to 1.2 mM, corresponding modulated frequency varies from 1090 MHz to 1145 MHz for signals captured at 25 cm away from the bandage. For pH modulation ranging from 2 to 10, the corresponding modulated frequency was between 800 MHz and 830 MHz for signals received at more than 6 feet away from the bandage. For quick and reliable assessment, two empirical models were developed for the direct frequency modulation as a function of uric acid and pH. To the best of our knowledge, this is the first time an all-textile (fabric-integrated), battery-free and wirelessly powered smart bandage have been proposed for wound monitoring. This result can be used as a first step in developing RFID-type, battery-free, and low-cost 5 G/6 G smart bandages using millimeterwave and terahertz frequencies where the bedsheet can be host to a MIMO-aided beamforming.


  • Open Access

    Correlating the Effect of Dynamic Variability in the Sensor Environment on Sensor Design

    by Pulak Bhushan

    This dissertation studies the effect of biofluid dynamics on the electrochemical response of a wearable sensor for monitoring of chronic wounds. The research investigates various dynamic in vivo parameters and correlates them with experimentally measured behavior with wound monitoring as a use case. Wearable electrochemical biosensors suffer from several unaddressed challenges, like stability and sensitivity, that need to be resolved for obtaining accurate data. One of the major challenges in the use of these sensors is continuous variation in biofluid composition. Wound healing is a dynamic process with wound composition changing continuously. This dissertation investigates the effects of several in vivo biochemical and environmental parameters on the sensor response to establish actionable correlations. Real-time assessment of wound healing was carried out through longitudinal monitoring of uric acid and other wound fluid characteristics. A textile sensor was designed using a simple fabrication approach combining conductive inks with a polymeric substrate, for conformal contact with the wound bed. A −1 cm−2, establishing the applicability of the sensor for measurements in the physiologically relevant range. The sensor was also found to be stable for a period of 3 days when subjected to physiological and elevated temperatures (37oC and 40oC) confirming its relevance for long-term monitoring. A direct correlation between sensor response and the dynamic parameters was seen, with the results showing a ~20% deviation from the accurate UA reading. The results confirmed that as a consequence of these parameters temporally changing in the wound environment, the sensor response will be altered. The work develops mathematical models correlating this effect on sensor response to allow for real-time sensor calibration. The clinical validation studies established the feasibility of UA measurement by the developed electrochemical sensor and derive correlations between the wound chronicity and UA levels. The protocols developed in this work for the design, fabrication, and calibration of the sensor to correct for the dynamic in vivo behavior can be extended to any wearable sensor for improved accuracy.


  • Ashok chakra-structured meta-structure as a perfect sound absorber for broadband low-frequency sound

    by Shantanu Bhattacharya, Sanjay Kumar, Sanjeet Kumar Singh, Pulak Bhushan, Megha Sahu, Om Prakash

    We present thin acoustic meta-structures with subwavelength dimensions through which almost perfect sound absorption is achieved in the low-frequency domain. Our overall strategy builds on the fact that the sound absorption capabilities of the meta-structures primarily depend on the geometric dimensions and can easily be reconfigured as per requirements through a change of geometry. To analyze various possibilities, we optimize the geometric structure through hybrid regression analysis using the genetic algorithm approach and finite element-based numerical simulations so that the geometry is tuned for high attenuation of acoustic signals over a broad range of frequencies. Both theoretical and experimental data show good parity and are able to establish the meta-structure nature of the assembly with respect to different frequency bands in the low frequency domain.


  • Toxicity assessment of wearable wound sensor constituents on keratinocytes

    by Pulak Bhushan, Yogeswaran Umasankar, Joshua D. Hutcheson, Shekhar Bhansali


  • Biosensor for Monitoring Uric Acid in Wound and Its Proximity: A Potential Wound Diagnostic Tool

    by Pulak Bhushan, Yogeswaran Umasankar, Sohini RoyChoudhury, Penelope A. Hirt, Flor E. MacQuhaec, Luis J. Borda, Hadar A. Lev-Tov, Robert S. Kirsner, Shekhar Bhansali

    This work reports a bi-enzymatic biosensor for monitoring uric acid (UA) in biofluids extracted from wound, perilesional skin and healthy skin. The biosensor is composed of uricase (UOx) as a biocatalyst for UA oxidation, horseradish peroxidase (HRP) for electron transfer and a nanocomposite of multi-walled carbon nanotubes (MWCNTs) and Au nanoparticles (AuNPs) as the substrate. The bi-enzymatic approach provided a two-fold enhancement in current response, while the nanocomposite facilitated higher enzyme loading and fast electron transfer enabling a 2-fold increase in current response. The biosensor was able to measure UA levels in human wound exudate and in biofluids extracted from perilesional and healthy skin. The biosensor exhibited a lowest detectable concentration of 9.91 μM with a sensitivity of 2.5 nA μM−1. The UA levels in wound exudate and biofluid extract from perilesional skin were 3.7 and 1.2 times higher than in healthy skin. This result opened a potential way to use the biofluid in wound proximity as a biomarker for prolonged measurements, preventing electrode occlusion and sensor fouling by the wound debris. The electrode fouling studies demonstrated that the electrode with adsorbed wound exudate had 1.5 times reduction in current compared to electrode adsorbed with biofluid extract from perilesional skin.


  • Open Access

    Additive manufacturing as an emerging technology for fabrication of microelectromechanical systems (MEMS)

    by Sanjay Kumar, Pulak Bhushan, Mohit Pandey, Shantanu Bhattacharya

    The recent success of additive manufacturing processes (also called, 3D printing) in the manufacturing sector has led to a shift in the focus from simple prototyping to real production-grade technology. The enhanced capabilities of 3D printing processes to build intricate geometric shapes with high precision and resolution have led to their increased use in fabrication of microelectromechanical systems (MEMS). The 3D printing technology has offered tremendous flexibility to users for fabricating custom-built components. Over the past few decades, different types of 3D printing technologies have been developed. This article provides a comprehensive review of the recent developments and significant achievements in most widely used 3D printing technologies for MEMS fabrication, their working methodology, advantages, limitations, and potential applications. Furthermore, some of the emerging hybrid 3D printing technologies are discussed, and the current challenges associated with the 3D printing processes are addressed. Finally, future directions for process improvements in 3D printing techniques are presented.


  • Open Access

    Nanocomposite Bienzymatic Sensor for Monitoring Xanthine in Wound Diagnostics

    by Sohini RoyChoudhury, Yogeswaran Umasankar, Pulak Bhushan, Penelope A. Hirt, Flor E. MacQuhae, Luis J. Borda, Hadar A. Lev-Tov, Robert Kirsner, Shekhar Bhansali

    This work reports a biosensor for monitoring xanthine for potential wound healing assessment. Active substrate of the biosensor has xanthine oxidase (XO) and horseradish peroxidase (HRP) physisorbed on a nanocomposite of multiwalled carbon nanotubes (MWCNT) decorated with gold nanoparticles (AuNP). The presence of HRP provided a two-fold increase in response to xanthine, and a three-fold increase in response to the nanocomposite. With a sensitivity of 155.71 nA μM−1 cm−2 the biosensor offers a detection limit of 1.3 μM, with linear response between 22 μM and 0.4 mM. Clinical sample analyses showed the feasibility of xanthine detection from biofluids in a lesion site due to diffusion of the analyte into surrounding biofluids. Higher concentrations by three-fold were observed from wound proximity, than away from injury, with an average recovery of 110%. Results show the feasibility of monitoring wound severity through longitudinal measurements of xanthine from injured vicinity.


  • Investigation of structure–mechanical property relationship in fused filament fabrication of the polymer composites

    by Sanjay Kumar, Pulak Bhushan, Nishant Sinha, Om Prakash, Shantanu Bhattacharya

    Fused filament fabrication (FFF) process is an emerging 3D printing technique primarily used for rapid prototyping in academic and industrial environments. The mechanical properties of these 3D-printed samples are highly anisotropic in nature and depend on various process parameters. Literature suggests that build orientation is a crucial parameter affecting the mesostructural and mechanical properties of these parts. However, there are no existing models that can correlate the mechanical properties of these printed parts with their mesostructural properties. Herein, a multiparametric mathematical model has been developed, establishing a correlation between the tensile strength, neck length, and pore size of the printed parts. An extensive investigation is carried out on six materials, namely acrylonitrile butadiene styrene (ABSplus P430, ABS POLYLAC® PA-757, and LG ABS RS657), polycarbonate (PC), FDM Nylon 12, and PC-ABS alloys printed in two different build orientations (XZ and ZX). The change in mechanical properties with respect to build orientation and the mesostructural properties was examined. It was established that parts printed in the XZ orientation exhibit a higher tensile strength, owing to the higher neck length and smaller pore size. Regression analysis was carried out to develop mathematical models correlating the tensile strength with the mesostructural properties of the printed parts. A good agreement is observed between the theoretically predicted and experimentally found tensile strength.


  • (Invited) Multimodal Enzymatic Sensing for Continuous Wound Monitoring

    by Sohini RoyChoudhury, Pulak Bhushan, Yogeswaran Umasankar, Penelope A. Hirt, Hadar A. Lev-Tov, Robert S. Kirsner, Shekhar Bhansali

    Present wound care is primarily visual, entailing repeated clinical trips. A biosensing system offering direct longitudinal measures of healing can assist to bridge the time between occurrence of wounds and their management. Purine metabolites, xanthine and uric acid, are known to have high correlation with wound chronicity and healing. With increased apoptosis, concentrations of these analytes reportedly increase. In this study, their biochemical pathways in purine metabolism are explored to provide a method to monitor healing on a multimodal sensing platform. This work employs enzymes xanthine oxidase and uricase, for detection of uric acid and xanthine respectively. pH of wounds change with healing, from alkaline to acidic, shifting the potential of detection. Effects of pH have been investigated on the same platform enabling real-time calibration, attempting to provide improved assessment of tissue recovery. Nanomaterials of carbon (C) and gold (Au) have been utilized here, to improve the sensitivity of detection.


  • Tapered lateral flow immunoassay based point-of-care diagnostic device for ultrasensitive colorimetric detection of dengue NS1

    by Sanjay Kumar, Pulak Bhushan, Vinay Krishna, Shantanu Bhattacharya

    Dengue virus, a Flaviviridae family member, has emerged as a major worldwide health concern, making its early diagnosis imperative. Lateral flow immunoassays have been widely employed for point-of-care diagnosis of dengue because of their rapid naked eye readouts, ease of use, and cost-effectiveness. However, they entail a drawback of low sensitivity, limiting their usage in clinical applications. Herein, we report a novel lateral flow immunoassay for detection of dengue leveraging on the benefits of gold decorated graphene oxide sheets as detection labels and a tapered nitrocellulose membrane. The developed assay allows for rapid (10 min) and sensitive detection of dengue NS1 with a detection limit of 4.9 ng mL−1, ∼11-fold improvement over the previously reported values. Additionally, the clinical application of the developed assay has been demonstrated by testing it for dengue virus spiked in human serum. The reported lateral flow immunoassay shows significant promise for early and rapid detection of several target diseases.