Development of in vivo measuring system of the pressure distribution under the denture base of removable partial denture
Authors:
- Kei KuboKKKei Kubo
- Tetsuo KawataTKTetsuo Kawata
- Hanako SuenagaHSHanako Suenaga
- Nobuhiro YodaNYNobuhiro Yoda
- Ryuji ShigemitsuRSRyuji Shigemitsu
- Toru OgawaTOToru Ogawa
- Keiichi SasakiKSKeiichi Sasaki
- 1 January 2009
- journal article
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 53 (1) , 15-21
Abstract
To develop a system to measure the pressure distribution under the base of a removable partial denture (RPD) and to apply it in vivo. A tactile sensor sheet with 100 sensing points and a measuring system (I-SCAN, Nitta, Osaka, Japan) were used. The sensor was calibrated before being applied in vivo. A subject with a mandibular RPD (Kennedy class II, division 1) participated in this study, and the RPD was duplicated as the experimental denture. The basal surface at distal extension was accommodated to the sensor in a manner similar to direct relining. Measurements were performed with three patterns of occlusal rest design (mesial and distal rests, mesial rest only, and without a rest) during maximal voluntary clenching (MVC) and gum chewing. The calibration measurements showed that the output value from each sensing point and total output of sensing points were positively correlated with the applied load. The pressures recorded in vivo varied depending on the locations of sensing points on the basal surface of the denture. During MVC the pressure distribution changed with the clenching level, and the highest pressure was registered near the residual ridge crest. The pressure distribution also changed according to the number of occlusal rests. The load center shifted about 2mm during MVC and about 4mm during gum chewing. The measuring system developed here enabled us to measure the pressure distribution under the denture base of RPD. The pressure distribution varied along with the design of the occlusal rest.Keywords
This publication has 22 references indexed in Scilit:
- Influence of Abutment Selection in Maxillary Kennedy Class II RPD on Elastic Stress Distribution in Oral Mucosa: An FEM StudyJournal of Prosthodontics, 2006
- Effect of Major Connectors in the Mandibular Removable Partial Denture on the Pressure Distribution.Nihon Hotetsu Shika Gakkai Zasshi, 2001
- Influence of Buccal Interocclusal Distance on the Pressure Distribution. In Vitro Study.Nihon Hotetsu Shika Gakkai Zasshi, 2000
- Influence of a Soft Lining Material on the Stress Distributions in Denture-supporting Tissues. The Finite Element Analysis Using the Contact Elements.Nihon Hotetsu Shika Gakkai Zasshi, 2000
- The Influence of Clasp Designs on Stress Distribution of Abutment Teeth and Displacement of Denture Base under Horizontal Loads.Nihon Hotetsu Shika Gakkai Zasshi, 1999
- In vivo Assessment of Occlusal Stress Distribution in Free-end Saddle Removable Partial Dentures. Part 1. Stress Distribution in Various Removable Partial Dentures.Nihon Hotetsu Shika Gakkai Zasshi, 1997
- Fundamental Studies on Functional Pressure and Stress-Bearing. II-2. Centric Occlusion of Upper Complete Denture.Nihon Hotetsu Shika Gakkai Zasshi, 1993
- Pressures recorded at the denture base?mucosal surface interface in complete denture wearersJournal of Oral Rehabilitation, 1987
- A comparison of two methods of quantifying masticatory pressures developed under dentures with variable occlusal widthsJournal of Oral Rehabilitation, 1979
- Strain on the framework of a mandibular free-end saddle partial denture under loadJournal of Biomedical Materials Research, 1967