Ryuji Shigemitsu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ryuji Shigemitsu has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Keiichi Sasaki
6 shared publicationsNobuhiro Yoda
Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, Sendai, 980-8575, Japan
4 shared publicationsToru Ogawa
Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, Sendai 980-8575, Japan
4 shared publications- Toru Ogawa
Division of Comprehensive Dentistry Tohoku University Hospital Sendai Japan
4 shared publications - Ahmed Reda Sammour2 shared publications
Aya Ito-Shibamoto
2 shared publications
Latest Publications
- Open Access
- 5 October 2026
- Published by Elsevier in Materialia
- Vol. 50
Microwave-assisted nitriding of titanium alloy forms a graded titanium nitride surface with enhanced hardness and preserved gingival fibroblast cytocompatibility
- 5 October 2026
- Published by Elsevier in Materialia
- Vol. 50
Open AccessMicrowave-assisted nitriding of titanium alloy forms a graded titanium nitride surface with enhanced hardness and preserved gingival fibroblast cytocompatibility
- Open Access
- 5 August 2026
- Published by Elsevier in SSRN Electronic Journal
Microwave-Assisted Nitriding of Titanium Alloy Forms a Graded Titanium Nitride Surface with Enhanced Hardness and Preserved Gingival Fibroblast Cytocompatibility
This study investigated the phase composition, surface characteristics, near-surface hardness, and gingival fibroblast response of Ti-6Al-4V modified by microwave-assisted nitriding for potential implant-abutment applications. Mirror-polished Ti-6Al-4V discs were treated by microwave-assisted nitriding at 800 or 850 °C and compared with uncoated Ti-6Al-4V and conventionally ion-plated titanium nitride. Commercially pure titanium was included as a reference for cell assays. Both microwave-treated groups exhibited gold-colored, wave-like surfaces with significantly greater roughness than uncoated Ti-6Al-4V and ion-plated titanium nitride. X-ray diffraction revealed titanium nitride, Ti₂N, and TiNₓ phases, with stronger nitride-related peaks after treatment at 850 °C. Glow discharge optical emission spectroscopy showed a gradual elemental transition extending to approximately 8 μm in the microwave-treated groups, whereas ion-plated titanium nitride showed an abrupt transition at approximately 1 μm. The microwave-treated groups exhibited increased near-surface hardness, with the 850 °C treatment showing the highest hardness. Human gingival fibroblast-1 metabolic activity showed no significant differences among groups after 1 or 6 days of culture. These findings indicate that microwave-assisted nitriding can produce a hard, compositionally graded titanium nitride-containing surface on Ti-6Al-4V while maintaining early gingival fibroblast cytocompatibility in vitro.
- 5 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMicrowave-Assisted Nitriding of Titanium Alloy Forms a Graded Titanium Nitride Surface with Enhanced Hardness and Preserved Gingival Fibroblast Cytocompatibility
This study investigated the phase composition, surface characteristics, near-surface hardness, and gingival fibroblast response of Ti-6Al-4V modified by microwave-assisted nitriding for potential implant-abutment applications. Mirror-polished Ti-6Al-4V discs were treated by microwave-assisted nitriding at 800 or 850 °C and compared with uncoated Ti-6Al-4V and conventionally ion-plated titanium nitride. Commercially pure titanium was included as a reference for cell assays. Both microwave-treated groups exhibited gold-colored, wave-like surfaces with significantly greater roughness than uncoated Ti-6Al-4V and ion-plated titanium nitride. X-ray diffraction revealed titanium nitride, Ti₂N, and TiNₓ phases, with stronger nitride-related peaks after treatment at 850 °C. Glow discharge optical emission spectroscopy showed a gradual elemental transition extending to approximately 8 μm in the microwave-treated groups, whereas ion-plated titanium nitride showed an abrupt transition at approximately 1 μm. The microwave-treated groups exhibited increased near-surface hardness, with the 850 °C treatment showing the highest hardness. Human gingival fibroblast-1 metabolic activity showed no significant differences among groups after 1 or 6 days of culture. These findings indicate that microwave-assisted nitriding can produce a hard, compositionally graded titanium nitride-containing surface on Ti-6Al-4V while maintaining early gingival fibroblast cytocompatibility in vitro.
- Open Access
- 11 July 2026
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 12 (1)
One-year marginal bone loss and survival rate of triangular-neck dental implants: a systematic review and meta-analysis
Purpose: This systematic review aimed to evaluate the clinical performance of dental implants with a triangular neck, focusing on 1-year marginal bone loss (MBL) and implant survival rate. Methods: This review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. A comprehensive search of databases (PubMed, Scopus, and Web of Science) was completed on June 8, 2025. Randomized controlled trials (RCTs), retrospective and prospective studies, and case series that studied ≥ 10 implants, reporting on triangular-neck implants, were included. The Cochrane risk of bias 2 tool was used for RCTs, and the Joanna Briggs Institute case series checklist was used for nonrandomized studies. The results were summarized using a random-effects meta-analysis and sensitivity analysis was performed to assess robustness. The Grading of Recommendations Assessment, Development, and Evaluation (GRADE) method was used to determine the certainty of evidence. Results: The search provided 115 titles after removal of duplicates. Eight studies met the inclusion criteria, five of which provided sufficient data for quantitative synthesis. The pooled analysis demonstrated a 1-year mean MBL of 0.35 mm (95% confidence interval [CI]: 0.24–0.46; heterogeneity; I 2 = 23.2%; p = 0.25) and an implant survival rate of 97.8% (95% CI: 95.4%–99.4%; I 2 = 0.0%; p = 0.96). Conclusions: Available single-arm evidence indicates that triangular-neck implants were associated with high implant survival rates and limited marginal bone level changes during the first year of follow-up. However, the current evidence does not permit conclusions regarding comparative clinical benefits relative to other implant designs.
- 11 July 2026
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 12 (1)
Open AccessOne-year marginal bone loss and survival rate of triangular-neck dental implants: a systematic review and meta-analysis
Purpose: This systematic review aimed to evaluate the clinical performance of dental implants with a triangular neck, focusing on 1-year marginal bone loss (MBL) and implant survival rate. Methods: This review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. A comprehensive search of databases (PubMed, Scopus, and Web of Science) was completed on June 8, 2025. Randomized controlled trials (RCTs), retrospective and prospective studies, and case series that studied ≥ 10 implants, reporting on triangular-neck implants, were included. The Cochrane risk of bias 2 tool was used for RCTs, and the Joanna Briggs Institute case series checklist was used for nonrandomized studies. The results were summarized using a random-effects meta-analysis and sensitivity analysis was performed to assess robustness. The Grading of Recommendations Assessment, Development, and Evaluation (GRADE) method was used to determine the certainty of evidence. Results: The search provided 115 titles after removal of duplicates. Eight studies met the inclusion criteria, five of which provided sufficient data for quantitative synthesis. The pooled analysis demonstrated a 1-year mean MBL of 0.35 mm (95% confidence interval [CI]: 0.24–0.46; heterogeneity; I 2 = 23.2%; p = 0.25) and an implant survival rate of 97.8% (95% CI: 95.4%–99.4%; I 2 = 0.0%; p = 0.96). Conclusions: Available single-arm evidence indicates that triangular-neck implants were associated with high implant survival rates and limited marginal bone level changes during the first year of follow-up. However, the current evidence does not permit conclusions regarding comparative clinical benefits relative to other implant designs.
- Open Access
- 2 January 2026
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (5) , 954.e1-954.e14
Anomaly detection of screw loosening of different implant-abutment connection designs using resonance frequency analysis: An in vitro study
- 2 January 2026
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (5) , 954.e1-954.e14
Open AccessAnomaly detection of screw loosening of different implant-abutment connection designs using resonance frequency analysis: An in vitro study
- Open Access
- 20 November 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 184, 109441
Kinematic classification of mandibular movements in patients with temporomandibular disorders based on PCA
- 20 November 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 184, 109441
Open AccessKinematic classification of mandibular movements in patients with temporomandibular disorders based on PCA
- Open Access
- 1 February 2021
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 129, 104173
The effects of bone remodeling on biomechanical behavior in a patient with an implant-supported overdenture
- 1 February 2021
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 129, 104173
Open AccessThe effects of bone remodeling on biomechanical behavior in a patient with an implant-supported overdenture
- Open Access
- 1 January 2018
- Published by Japan Prosthodontic Society in Annals of Japan Prosthodontic Society
- Vol. 10 (4) , 365-368
A Case of Occlusal Reconstruction using a Combination Splint
症例の概要:患者は初診時57歳の男性.歯列の部分欠損と鋏状咬合を認め咬頭嵌合位の咬合接触は不安定であった.上顎にコンビネーションスプリント(残存歯列の咬合面全体を被覆した治療用義歯)を装着し咬合位の安定を図った後に最終補綴を行った. 考察:フェイスボウトランスファーとクロスマウント法を用いて,コンビネーションスプリントを装着した状態での咬合要素を最終義歯へと反映した.これにより,咀嚼能率の向上と口腔関連QOL の改善が達成できた. 結論:下顎位が不安定な症例では最終補綴に先立ち,治療用義歯により咬合支持の確立と咬合位の安定を図ることが重要である.
- 1 January 2018
- Published by Japan Prosthodontic Society in Annals of Japan Prosthodontic Society
- Vol. 10 (4) , 365-368
Open AccessA Case of Occlusal Reconstruction using a Combination Splint
症例の概要:患者は初診時57歳の男性.歯列の部分欠損と鋏状咬合を認め咬頭嵌合位の咬合接触は不安定であった.上顎にコンビネーションスプリント(残存歯列の咬合面全体を被覆した治療用義歯)を装着し咬合位の安定を図った後に最終補綴を行った. 考察:フェイスボウトランスファーとクロスマウント法を用いて,コンビネーションスプリントを装着した状態での咬合要素を最終義歯へと反映した.これにより,咀嚼能率の向上と口腔関連QOL の改善が達成できた. 結論:下顎位が不安定な症例では最終補綴に先立ち,治療用義歯により咬合支持の確立と咬合位の安定を図ることが重要である.
- 1 November 2014
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 54, 44-52
Biological-data-based finite-element stress analysis of mandibular bone with implant-supported overdenture
- 1 November 2014
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 54, 44-52
Biological-data-based finite-element stress analysis of mandibular bone with implant-supported overdenture
- 29 June 2012
- Published by Springer Nature in Odontology
- Vol. 101 (2) , 222-226
Stress distribution in the peri-implant bone with splinted and non-splinted implants by in vivo loading data-based finite element analysis
The aim of this study was to evaluate stress distribution in peri-implant bone and to investigate the influence of splinting implants by finite element analysis (FEA) with in vivo loading data. The magnitude and direction of the force exerted on implants during maximal voluntary clenching of a subject were recorded with 3-D piezoelectric force transducers. FEA using in vivo loading data was conducted on splinted and non-splinted models with two implants. Overall, the splinted model reduced stress in peri-implant bone in comparison with the non-splinted model.
- 29 June 2012
- Published by Springer Nature in Odontology
- Vol. 101 (2) , 222-226
Stress distribution in the peri-implant bone with splinted and non-splinted implants by in vivo loading data-based finite element analysis
The aim of this study was to evaluate stress distribution in peri-implant bone and to investigate the influence of splinting implants by finite element analysis (FEA) with in vivo loading data. The magnitude and direction of the force exerted on implants during maximal voluntary clenching of a subject were recorded with 3-D piezoelectric force transducers. FEA using in vivo loading data was conducted on splinted and non-splinted models with two implants. Overall, the splinted model reduced stress in peri-implant bone in comparison with the non-splinted model.
- 1 January 2009
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 53 (1) , 15-21
Development of in vivo measuring system of the pressure distribution under the denture base of removable partial denture
To develop a system to measure the pressure distribution under the base of a removable partial denture (RPD) and to apply it in vivo. A tactile sensor sheet with 100 sensing points and a measuring system (I-SCAN, Nitta, Osaka, Japan) were used. The sensor was calibrated before being applied in vivo. A subject with a mandibular RPD (Kennedy class II, division 1) participated in this study, and the RPD was duplicated as the experimental denture. The basal surface at distal extension was accommodated to the sensor in a manner similar to direct relining. Measurements were performed with three patterns of occlusal rest design (mesial and distal rests, mesial rest only, and without a rest) during maximal voluntary clenching (MVC) and gum chewing. The calibration measurements showed that the output value from each sensing point and total output of sensing points were positively correlated with the applied load. The pressures recorded in vivo varied depending on the locations of sensing points on the basal surface of the denture. During MVC the pressure distribution changed with the clenching level, and the highest pressure was registered near the residual ridge crest. The pressure distribution also changed according to the number of occlusal rests. The load center shifted about 2mm during MVC and about 4mm during gum chewing. The measuring system developed here enabled us to measure the pressure distribution under the denture base of RPD. The pressure distribution varied along with the design of the occlusal rest.
- 1 January 2009
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 53 (1) , 15-21
Development of in vivo measuring system of the pressure distribution under the denture base of removable partial denture
To develop a system to measure the pressure distribution under the base of a removable partial denture (RPD) and to apply it in vivo. A tactile sensor sheet with 100 sensing points and a measuring system (I-SCAN, Nitta, Osaka, Japan) were used. The sensor was calibrated before being applied in vivo. A subject with a mandibular RPD (Kennedy class II, division 1) participated in this study, and the RPD was duplicated as the experimental denture. The basal surface at distal extension was accommodated to the sensor in a manner similar to direct relining. Measurements were performed with three patterns of occlusal rest design (mesial and distal rests, mesial rest only, and without a rest) during maximal voluntary clenching (MVC) and gum chewing. The calibration measurements showed that the output value from each sensing point and total output of sensing points were positively correlated with the applied load. The pressures recorded in vivo varied depending on the locations of sensing points on the basal surface of the denture. During MVC the pressure distribution changed with the clenching level, and the highest pressure was registered near the residual ridge crest. The pressure distribution also changed according to the number of occlusal rests. The load center shifted about 2mm during MVC and about 4mm during gum chewing. The measuring system developed here enabled us to measure the pressure distribution under the denture base of RPD. The pressure distribution varied along with the design of the occlusal rest.