Perfluorocarbon Compound Aerosols for Delivery to the Lung as Potential 19F Magnetic Resonance Reporters of Regional Pulmonary pO2
Authors:
- Stephen R. ThomasSTStephen R. Thomas
- Leon GradonLGLeon Gradon
- Sotiris E. PratsinisSPSotiris E. Pratsinis
- Ronald G. PrattRPRonald G. Pratt
- George P. FotouGFGeorge P. Fotou
- ANTHONY J. McGORONAMANTHONY J. McGORON
- Albert L. PodgorskiAPAlbert L. Podgorski
- Ronald W. MillardRMRonald W. Millard
- 1 January 1997
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 32 (1) , 29-38
Abstract
RATIONALE AND OBJECTIVES Perfluorocarbon (PFC) aerosols present the opportunity for simultaneous analysis of lung structure and pulmonary oxygenation patterns. The authors investigated techniques to nebulize neat liquid PFCs for inhalation as a new method of PFC administration and tested the hypothesis that PFC aerosols may be developed for efficient delivery to the lung in an experimental rat model allowing the potential for sequential monitoring of pulmonary status via quantitative fluorine-19 (19F) magnetic resonance (MR) partial pressure of oxygen (pO2) imaging. METHODS Pneumatic aerosol generators were configured to produce a neat liquid PFC perfluorotributylamine (FC-43) aerosol. Perfluorocarbon inhalation breathing protocols for the rat model included: spontaneous direct breathing from an aerosol chamber, and use of a tracheotomy tube to bypass nasal breathing. The PFC aerosol delivery into the rat lung was documented through 19F MR imaging in correlation with high-resolution anatomic proton MR images. Theoretical model calculations for PFC mass deposition were compared with experimental results. RESULTS The pneumatic generator produced a PFC aerosol droplet within the theoretically targeted range (geometric mean particle diameter of 1.2 µm; concentration of ~4 X 107 droplets per cm3). No measurable aerosol reached the lungs during spontaneous breathing because of the efficient filtering capabilities of the turbinated nasal passages. With tracheotomy, aerosol depositions within the lung were achieved in mass quantities consistent with theoretical expectations; however, the distribution patterns were nonuniform and unpredictable. Oxygen-enhanced 19F imaging was demonstrated. CONCLUSIONS Perfluorocarbon aerosols of controlled size distribution can be produced at sufficient concentration with pneumatic generators for distribution to the terminal pulmonary architecture and visualization using 19F MR imaging. The potential exists for in vivo oxygen-sensitive imaging in the pulmonary system and development of sophisticated experimental animal models of systemic oxygen transport as a function of pulmonary status.Keywords
This publication has 24 references indexed in Scilit:
- In vivo pO2 imaging in the porcine model with perfluorocarbon F-19 NMR at low fieldMagnetic Resonance Imaging, 1996
- Evaluation of the influence of the aqueous phase bioconstituent environment on the F‐19 T1 of perfluorocarbon blood substitute emulsionsJournal of Magnetic Resonance Imaging, 1994
- Imaging oxygen tension in liver and spleen by 19F NMRMagnetic Resonance in Medicine, 1993
- A noninvasive assessment of myocardial oxygen tension: 19f nmr spectroscopy of sequestered perfluorocarbon emulsionMagnetic Resonance in Medicine, 1992
- Measurement of Preretinal Oxygen Tension in the Vitrectomized Human Eye Using Fluorine-19 Magnetic Resonance SpectroscopyArchives of Ophthalmology (1950), 1992
- Measurement of lung clearance with pulses of radioactively-labelled aerosolsJournal of Aerosol Science, 1986
- MR Imaging of the Lung Using Liquid PerfluorocarbonsJournal of Computer Assisted Tomography, 1986
- Fluorine-19 relaxation study of perfluoro chemicals as oxygen carriersThe Journal of Physical Chemistry, 1983
- The solubility of oxygen in highly fluorinated liquidsJournal of Fluorine Chemistry, 1977
- Survival of Mammals Breathing Organic Liquids Equilibrated with Oxygen at Atmospheric PressureScience, 1966