STStephen R. Thomas

Stephen R. Thomas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Stephen R. Thomas has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • James G. Kereiakes, Ph.D.

    by William Hendee, Guy Simmons, Stephen R. Thomas, Stephen J. Pomeranz

  • The proposed MOC requirements for physicists are reasonable

    by Stephen R. Thomas, Jeffrey A. Garrett, Colin G. Orton


  • Deployment of a maintenance of certification program in medical physics serves the interest of the profession and the public

    by Stephen R. Thomas, Joseph S. Blinick, William R. Hendee

    • 1 March 2005
      • Vol. 46  (3) , 502-8

    Radiation-absorbed dose from 201Tl-thallous chloride.

    by Stephen R Thomas, Michael G Stabin, Frank P Castronovo

    Revised radiation dosimetry estimates for 201Tl-thallous chloride have been developed using new data specifically acquired to address the issue of testicular uptake of this agent and through reevaluation of extant data for biodistribution in other organs. Quantitative testicular scintigraphy data of sequestered testes (body-background shielded) were obtained from 28 patients (56 studies) injected with 201Tl-thallous chloride at peak exercise. Previously published data for 15 patients injected at maximal exercise were reanalyzed to obtain updated biodistribution parameters for designated organs. Radiation dose was calculated according to the MIRD schema. Radiation dose to testes as a function of age was determined. Comparisons are made between organ dose estimates derived in this study and those previously published. The dose contributions of possible contaminants (200Tl, 202Tl, 203Pb) have been included. Estimates are provided of the dose component from these contaminants if injected at the time of the maximum recommended 5-d shelf life (as opposed to at the designated calibration time). The radiation dose per unit administered activity to adult testes calculated in this study of 0.21 mGy/MBq (0.77 rad/mCi) is approximately a factor of 2 less than the value of 0.45 mGy/MBq (1.7 rad/mCi) previously accepted. The revised dose estimates for other organs show less variation from published values. The effective dose determined in this work is approximately 0.16 mSv/MBq (0.60 rem/mCi). Under the assumption of similar biokinetics as for the adult, the testes dose for children increases significantly as age decreases with a value of 7.5 mGy/MBq (28 rad/mCi) for a newborn. Contributions from radiocontaminants that may be encountered in the preparation of 201Tl-thallous chloride are shown to range from a fraction of a percent up to approximately 20% of the total dose for some organs, with the higher values arising from the long half-life contaminant 202Tl after a 5-d shelf life. It is recommended that the dose values determined in this study be used when estimating the radiation dose to the adult testes from intravenous administration of 201Tl-thallous chloride. The potential for increased radiation dose per administered activity to the testes at younger ages should be evaluated before performing procedures on children. The presence of radiocontaminants in the product should be considered when estimating radiation dose and may add a significant contribution to dose dependent on the specific radionuclide and concentration at the time of administration.


  • The American Board of Radiology Maintenance of Certification (MOC) Program in Radiologic Physics

    by Stephen R. Thomas, William R. Hendee, Bhudatt R. Paliwal

    Maintenance of Certification (MOC) recognizes that in addition to medical knowledge, several essential elements involved in delivering quality care must be developed and maintained throughout one's career. The MOC process is designed to facilitate and document the professional development of each diplomate of The American Board of Radiology (ABR) through its focus on the essential elements of quality care in Diagnostic Radiology and its subspecialties, and in the specialties of Radiation Oncology and Radiologic Physics. The initial elements of the ABR-MOC have been developed in accord with guidelines of The American Board of Medical Specialties. All diplomates with a ten-year, time-limited primary certificate in Diagnostic Radiologic Physics, Therapeutic Radiologic Physics, or Medical Nuclear Physics who wish to maintain certification must successfully complete the requirements of the appropriate ABR-MOC program for their specialty. Holders of multiple certificates must meet ABR-MOC requirements specific to the certificates held. Diplomates with lifelong certificates are not required to participate in the MOC, but are strongly encouraged to do so. MOC is based on documentation of individual participation in the four components of MOC: (1) professional standing, (2) lifelong learning and self-assessment, (3) cognitive expertise, and (4) performance in practice. Within these components, MOC addresses six competencies: medical knowledge, patient care, interpersonal and communication skills, professionalism, practice-based learning and improvement, and systems-based practice.


  • Effective Dose of Dual-Energy X-Ray Absorptiometry Scans in Children as a Function of Age

    by Stephen R. Thomas, Heidi J. Kalkwarf, Donna D. Buckley, James E. Heubi


  • Options for Radionuclide Therapy: From Fixed Activity to Patient-Specific Treatment Planning

    by Stephen R. Thomas

    The therapeutic use of radioisotopes in medicine as unsealed sources has a long history dating back to the 1930s. The established and continuing objectives are to provide radiation dose to the target tissue at the desired cytotoxic level while avoiding or minimizing toxic effects. Selected radionuclide therapy protocols including 32P for polycythemia vera, 131I for Graves' disease, and 131I for postsurgical ablation of thyroid remnants in the management of differentiated thyroid cancer are presented for historical review with the focus on protocols for administering the radiopharmaceuticals and the role played by dosimetry. The discussion also includes consideration of complications and the assessment of outcome for these diseases. The vista for radionuclide therapy today is reviewed along with the options for determining the administered activity. Patient specific dosimetry encompasses a number of levels ranging from basic measurement of relevant biokinetic parameters and use of standard models to calculate (and extrapolate) radiation dose to sophisticated three-dimensional techniques employing fusion of physiologic and high-resolution anatomic images coupled with advanced 3-D voxel patient representation and Monte Carlo techniques for use in radiation dose calculation. The role of patient specific dosimetry in clinical trials (Phase I, II, III trials) along with its utility in treatment planning, follow-up evaluation, and elucidation of dose-response relationships is discussed. The challenge ahead for those who advocate patient specific dosimetry is to assemble the outcome data and perform the analysis to support this contention.


    • 1 February 2002
      • Vol. 43  (2) , 210-4

    MIRD dose estimate report no. 19: radiation absorbed dose estimates from (18)F-FDG.

    by Marguerite T Hays, Evelyn E Watson, Stephen R Thomas, Michael Stabin


  • Perfluorocarbon Compound Aerosols for Delivery to the Lung as Potential 19F Magnetic Resonance Reporters of Regional Pulmonary pO2

    by Stephen R. Thomas, Leon Gradon, Sotiris E. Pratsinis, Ronald G. Pratt, George P. Fotou, ANTHONY J. McGORON, Albert L. Podgorski, Ronald W. Millard

    RATIONALE AND OBJECTIVES Perfluorocarbon (PFC) aerosols present the opportunity for simultaneous analysis of lung structure and pulmonary oxygenation patterns. The authors investigated techniques to nebulize neat liquid PFCs for inhalation as a new method of PFC administration and tested the hypothesis that PFC aerosols may be developed for efficient delivery to the lung in an experimental rat model allowing the potential for sequential monitoring of pulmonary status via quantitative fluorine-19 (19F) magnetic resonance (MR) partial pressure of oxygen (pO2) imaging. METHODS Pneumatic aerosol generators were configured to produce a neat liquid PFC perfluorotributylamine (FC-43) aerosol. Perfluorocarbon inhalation breathing protocols for the rat model included: spontaneous direct breathing from an aerosol chamber, and use of a tracheotomy tube to bypass nasal breathing. The PFC aerosol delivery into the rat lung was documented through 19F MR imaging in correlation with high-resolution anatomic proton MR images. Theoretical model calculations for PFC mass deposition were compared with experimental results. RESULTS The pneumatic generator produced a PFC aerosol droplet within the theoretically targeted range (geometric mean particle diameter of 1.2 µm; concentration of ~4 X 107 droplets per cm3). No measurable aerosol reached the lungs during spontaneous breathing because of the efficient filtering capabilities of the turbinated nasal passages. With tracheotomy, aerosol depositions within the lung were achieved in mass quantities consistent with theoretical expectations; however, the distribution patterns were nonuniform and unpredictable. Oxygen-enhanced 19F imaging was demonstrated. CONCLUSIONS Perfluorocarbon aerosols of controlled size distribution can be produced at sufficient concentration with pneumatic generators for distribution to the terminal pulmonary architecture and visualization using 19F MR imaging. The potential exists for in vivo oxygen-sensitive imaging in the pulmonary system and development of sophisticated experimental animal models of systemic oxygen transport as a function of pulmonary status.