Investigating the Accuracy of Ultrasound Imaging in Measuring Fetal Weight in Comparison with the Actual Postpartum Weight
Authors:
- Sultan Abdulwadoud AlshoabiSASultan Abdulwadoud Alshoabi
- Abdulhadi M. TarshunATAbdulhadi M. Tarshun
- Ziyad O. AlnomanZAZiyad O. Alnoman
- Fahad H. AljohaniFAFahad H. Aljohani
- Fadwa M. AlahmadiFAFadwa M. Alahmadi
- Awatif M. OmerAOAwatif M. Omer
- Osamah M. AbdulaalOAOsamah M. Abdulaal
- Awadia GareeballahAGAwadia Gareeballah
- Abdulaziz A. QurashiAQAbdulaziz A. Qurashi
- Fahad H. AlhazmiFAFahad H. Alhazmi
- Kamal D. AlsultanKamal D. Alsultan
- Moawia GameraddinMGMoawia Gameraddin
Open Access
- 24 June 2025
- journal article
- research article
- Published by MDPI AG in Pediatric Reports
- Vol. 17 (4) , 70
Abstract
Background: Antenatal ultrasonography measurements of the estimated fetal weight (EFW) are a critical point in the decision-making process of obstetric planning and management to preserve the safety of both the newborn and the mother. This study aims to investigate the accuracy of ultrasonography to measure the EFW in comparison with the actual birth weight (BW) measured immediately after delivery. Methods: In this retrospective study, electronic records of 270 newborns who fulfilled the inclusion criteria were retrieved. A structured data sheet was used to collect the EFW, calculated by the Hadlock A formula using real-time ultrasound imaging on the day of delivery or the day before, and the actual BW immediately after delivery. Results: Out of 270 fetuses, 53.7% (145) were female, and 46.3% (125) were male. The mean BW was 2918.1 ± 652.81 g (range: 880 to 5100). The mean EFW was 3271.55 ± 691.47 g (range: 951 to 4942). The mean gestational age was 38 ± 2.48 weeks (range: 29 to 42). Spearman’s rho correlation test revealed strong compatibility between EFW and BW (r = 0.82, p < 0.001). Linear regression analysis showed a strong correlation between EFW and BW (R = 0.875, R2 = 0.766, and p < 0.001). The cross-tabulation test showed 86.8%, 78.4%, and 26.9% compatibility between measurements of EFW and the true BW in group-1 (4000 g) fetuses (p< 0.001). Conclusions: EFW using ultrasonography yields high compatibility with the actual BW. Despite the slight overestimation, ultrasonography provides high clinical value in obstetric assessment and subsequent management.Keywords
This publication has 27 references indexed in Scilit:
- Predicting abnormal fetal growth using deep learningnpj Digital Medicine, 2025
- Reimagining and Contextualizing Fetal Weight EstimationMCN: The American Journal of Maternal/Child Nursing, 2021
- Predicting fetal weight by three-dimensional limb volume ultrasound (AVol/TVol) and abdominal circumferenceChinese Medical Journal, 2021
- Comparison of the accuracy of INTERGROWTH-21 formula with other ultrasound formulae in fetal weight estimationTaiwanese Journal of Obstetrics and Gynecology, 2019
- Birth weight variants are associated with variable fetal intrauterine growth from 20 weeks of gestationScientific Reports, 2018
- Ultrasonographic estimation of fetal weight: development of new model and assessment of performance of previous modelsUltrasound in Obstetrics & Gynecology, 2018
- Ultrasound versus Clinical Examination to Estimate Fetal Weight at TermGeburtshilfe und Frauenheilkunde, 2017
- What are the limits of accuracy in fetal weight estimation with conventional biometry in two‐dimensional ultrasound? A novel postpartum studyUltrasound in Obstetrics & Gynecology, 2012
- Good accuracy of ultrasound estimations of fetal weight performed by midwivesActa Obstetricia et Gynecologica Scandinavica, 2007
- The effect of maternal height on birth weight and birth lengthEarly Human Development, 1991