Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kamal Dahan Alsultan has a total of 61 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Knowledge, Compliance, and Associated Factors of Radiation Protection Adherence Among Dental Students, Interns, and Dentists: A Cross-Sectional Study

    by Kamal Dahan Alsultan, Redhwan Saleh Al-Gabri, Awadia Gareeballah, Dayan Mohammed Alaydaa, Saeedah Omar Alrifi, Alya Waheed Hejazi, Suliman Salih, Moawia Gameraddin, Sultan Abdulwadoud Alshoabi, Faisal Alrehily, et al.

    Dental radiography is essential for diagnosis and treatment planning, but exposure to ionizing radiation requires strict adherence to radiation protection principles. This study evaluated radiation protection knowledge, self-reported compliance, and their associated factors among dental students, interns, and dentists. A cross-sectional study included 136 participants (86.1% response rate). A content-reviewed bilingual questionnaire assessed 7 knowledge items (6 scored in the composite knowledge score) and 12 self-reported compliance items. Pilot testing, translation, content validity (scale-level average content validity index [S-CVI/Ave] = 0.91), and internal consistency (α = 0.78; Kuder–Richardson Formula 20 [KR-20] = 0.70) were evaluated. Multivariable ordinary least squares regression examined factors associated with compliance using SPSS 27 and Python software. The composite knowledge score was 0.804; the pediatric radiation protection item had a correct-response rate of 54.4% (single-item assessment). Mean compliance was 3.09/4. Composite knowledge score was independently associated with self-reported compliance (B = 1.092, 95% confidence interval: 0.817–1.366, p < 0.001). Compliance was significantly lower among Year 5 students and interns than among Year 3 students (p = 0.037 and p = 0.005, respectively), whereas gender and the remaining training-level contrasts were not significant (R 2 = 0.360). Knowledge showed a moderate-to-strong positive correlation with compliance (rₛ= 0.528, p < 0.001). Exploratory analyses indicated a stronger knowledge–compliance association among more advanced trainees (Year 5, interns, and dentists/faculty) than among earlier-year students. The largest compliance gaps involved X-ray image repetition frequency, use of protective shielding devices, and motion-restraining tools. Composite knowledge score was independently associated with self-reported compliance, and adjusted compliance was lower among Year 5 students and interns than among Year 3 students. However, the cross-sectional design and reliance on self-reported data preclude causal interpretation. Lower compliance was observed for X-ray image repetition frequency, protective shielding devices, and motion-restraining tools. These findings support competency-based training and curriculum review, but recommendations remain exploratory and require confirmation in larger multi-institutional prospective studies.

  • Open Access

    Bridging TG‐116 and TG‐232: A retrospective multi‐vendor evaluation of deviation index re‐centering and process control in digital radiography

    by Ezzat AbuAzzah, Faisal Alrehily, Moawia Gameraddin, Sultan Alshoabi, Walaa Alsharif, Kamal Dahan Alsultan, Abdullah Alshamrani, Khaled Al‐Radadi, Ramy Badawy, Samer Al‐Jabri, et al.

    Background: The deviation index (DI) is a vendor‐neutral indicator of detector exposure relative to the configured target exposure index (TEI). Because TEI is a protocol value rather than a calibrated physical quantity, poorly aligned TEI settings can create systematic DI offsets, obscure protocol problems, and prevent meaningful statistical process control. Objective: This retrospective multi‐vendor study evaluated whether routine DICOM metadata can identify biased DI distributions, separate fixed TEI‐setting offsets from protocol‐adherence variation, estimate candidate TEI updates, and support TG‐232‐aligned standard deviation‐based monitoring after DI re‐centering. Methods: We retrospectively analyzed 38 916 digital radiography examinations performed from January 1, 2024 through August 27, 2024 using three vendor platforms at a tertiary hospital. DICOM metadata were benchmarked against published technical standards using a composite adherence index (CAI) for SID, kVp, mAs, grid use, and AEC use. A secondary gradient‐boosting/SHAP analysis was retained as a non‐causal variance discovery to rank the metadata patterns used to predict DI. Candidate TEI updates were estimated within the vendor‐region‐projection groups by algebraically re‐centering the observed mean DI ( to 0.0. Robustness was assessed using sensitivity analyses restricted by automatic exposure control, beam energy, and patient habitus proxy measures. Results: The baseline = −3.1 (SD 3.7), and only 11.3% of examinations were within |DI| ≤ 1. Forty of 45 vendor–region–projection groups (88.9%) had an absolute group greater than 1.0. Separately, the mean CAI was 0.176. The secondary SHAP analysis ranked the configured TEI, manufacturer, SID, exposure, and kVp as high‐contribution predictors of DI; these findings were interpreted as predictive attribution, not causal evidence. DI re‐centering reduced the overall variance by 42.9% (13.5 to 7.7), increased the proportion of examinations within |DI| ≤ 1 to 34.3%, and reduced severe deviations (|DI| > 3) from 60.3% to 23.1%. Conclusion: In this retrospective, multi‐vendor study, the TEI setting review was operationalized as a structured, data‐driven responsibility of a clinical site. By verifying protocol adherence, equipment performance, image quality, and dose indicators before centering the , departments can support the conversion of the DI from a biased compliance signal into a practical process‐control metric for exposure governance.

  • Open Access

    Perianal Fistulae Medical Imaging Maps: A Pictorial Diagnostic Review

    by Sultan Abdulwadoud Alshoabi, Abdulkhaleq Ayedh Binnuhaid, Abdullatif O. Magram, Abdullgabbar M. Hamid, Fahad H. Alhazmi, Abdulkareem Algahtani, Bashair Alhummiany, Kamal D. Alsultan, Alaa Alshoabi, Rahaf Hamid, et al.

    Perianal fistula, or anal fistula, is an abnormal granulomatous tract connecting the anal canal or rectum to the surrounding skin. It causes perianal pain and fistulous discharge, negatively impacting patients’ quality of life. The mechanism underlying fistula formation remains incompletely understood. Medical imaging is essential for accurate preoperative assessment of the shape, number and branching of fistulous tracts, identification of internal openings and Parks’ classification. This pictorial review provides an image-based overview of the key medical imaging concepts essential for the diagnosis of perianal fistulae and summarises the roles, advantages and limitations of the available imaging modalities for evaluating perianal fistulae. The current evidence on X-ray fistulography, computed tomography (CT) fistulography, transcutaneous ultrasonography (TCUS), endoanal ultrasonography (EAUS) and pelvic magnetic resonance imaging (MRI) was reviewed, emphasising on their diagnostic performance and clinical applications. Conventional X-ray fistulography has progressively been abandoned because it is invasive, is uncomfortable for patients, provides poor soft tissue contrast and inadequately visualises anal sphincters, complex fistulous tracts, secondary branches and abscesses. CT fistulography is useful for evaluating perianal abscesses and fistula when MRI and EAUS are unavailable. TCUS is widely available, non-invasive and radiation-free but is operator-dependent and has limited ability to evaluate high perianal fistulae. EAUS accurately evaluates fistulous tracts, can be performed at the bedside or intraoperatively and is reliable when MRI is contraindicated. However, EAUS is operator-dependent, is contraindicated in patients with severe anal stenosis or acute anal pain, and has a small field of view. Pelvic MRI is the gold standard, providing excellent visualisation of anal canal anatomy, superior soft tissue contrast, accurate mapping of fistulous tracts, localisation of internal openings, assessment of the involvement of anal sphincters and detection of secondary tracts, abscesses and associated complications. Consequently, MRI is a preferred imaging modality, which can guide treatment decisions and monitoring of treatment response.

  • Open Access

    Multisystemic Tuberculosis Masquerading as Aggressive Cardiac Tumor Causing Budd–Chiari Syndrome Disseminated to the Brain Resulting in Death of a Six-Year-Old Boy

    by Eman S. Al-Akhali, Sultan Abdulwadoud Alshoabi, Halah Fuad Muslem, Fahad H. Alhazmi, Amirah F. Alsaedi, Kamal D. Alsultan, Amel F. Alzain, Awatif M. Omer, Maisa Elzaki, Abdullgabbar M. Hamid

    Tuberculosis (TB) is an ancient and re-emerging granulomatous infectious disease that continues to challenge public health. Early diagnosis and prompt effective treatment are crucial for preventing disease progression and reducing both morbidity and mortality. These steps play a vital role in infection control and in lowering death rates at both individual and population levels. Although diagnostic methods have improved sufficiently in recent decades, TB can still present with ambiguous laboratory and imaging features. This ambiguity can lead to diagnostic pitfalls and potentially disastrous outcomes due to delayed diagnosis. In this article, we present a case of TB that was difficult to diagnose. The disease had invaded the mediastinum, right atrium, right coronary artery, and inferior vena cava (IVC), resulting in Budd–Chiari syndrome. This rare presentation created clinical, laboratory, and radiological confusion, resulting in a diagnostic dilemma that ultimately led to open cardiac surgery. The patient initially presented with progressive shortness of breath on exertion and fatigue, which suggested possible heart disease. This suspicion was reinforced by computed tomography (CT) imaging, which showed infiltrative mass lesions predominantly in the right side of the heart, invading the right coronary artery and IVC, with imaging features mimicking angiosarcoma. Although laboratory findings revealed an exudative effusion with lymphocyte predominance and elevated adenosine deaminase (ADA), the Gram stain was negative for bacteria, and an acid-fast bacilli (AFB) smear was also negative. These findings contributed to diagnostic uncertainty and delayed the confirmation of TB. Open surgery with excisional biopsy and histopathological analysis ultimately confirmed TB. We conclude that TB should not be ruled out solely based on negative Mycobacterium bacteria in pericardial effusion or AFB smear. TB can mimic aggressive tumors such as angiosarcoma or lymphoma with invasion of the surrounding tissues and blood vessels. Awareness of the clinical presentation, imaging findings, and potential diagnostic pitfalls of TB is essential, especially in endemic regions.

  • Open Access

    Investigating the Accuracy of Ultrasound Imaging in Measuring Fetal Weight in Comparison with the Actual Postpartum Weight

    by Sultan Abdulwadoud Alshoabi, Abdulhadi M. Tarshun, Ziyad O. Alnoman, Fahad H. Aljohani, Fadwa M. Alahmadi, Awatif M. Omer, Osamah M. Abdulaal, Awadia Gareeballah, Abdulaziz A. Qurashi, Fahad H. Alhazmi, et al.

    Background: Antenatal ultrasonography measurements of the estimated fetal weight (EFW) are a critical point in the decision-making process of obstetric planning and management to preserve the safety of both the newborn and the mother. This study aims to investigate the accuracy of ultrasonography to measure the EFW in comparison with the actual birth weight (BW) measured immediately after delivery. Methods: In this retrospective study, electronic records of 270 newborns who fulfilled the inclusion criteria were retrieved. A structured data sheet was used to collect the EFW, calculated by the Hadlock A formula using real-time ultrasound imaging on the day of delivery or the day before, and the actual BW immediately after delivery. Results: Out of 270 fetuses, 53.7% (145) were female, and 46.3% (125) were male. The mean BW was 2918.1 ± 652.81 g (range: 880 to 5100). The mean EFW was 3271.55 ± 691.47 g (range: 951 to 4942). The mean gestational age was 38 ± 2.48 weeks (range: 29 to 42). Spearman’s rho correlation test revealed strong compatibility between EFW and BW (r = 0.82, p < 0.001). Linear regression analysis showed a strong correlation between EFW and BW (R = 0.875, R2 = 0.766, and p < 0.001). The cross-tabulation test showed 86.8%, 78.4%, and 26.9% compatibility between measurements of EFW and the true BW in group-1 (4000 g) fetuses (p< 0.001). Conclusions: EFW using ultrasonography yields high compatibility with the actual BW. Despite the slight overestimation, ultrasonography provides high clinical value in obstetric assessment and subsequent management.

  • Open Access

    Cardiac amyloidosis: A diagnostic challenge

    by Eman S. Al_Akhali, Sultan A. Alshoabi, Abdullgabbar M. Hamid, Kamal D. Alsultan, Awatif M. Omer, Mohammed A. Alhammadi


  • Open Access

    Assessment of the Knowledge and Practice of Infection Control among Radiographers in Saudi Arabia: A Cross-Sectional Survey Study

    by Awadia Gareeballah, Samah Matar Al-Sehli, Rana Theeb Al-Mutairi, Moawia Gameraddin, Walaa Alsharif, Maisa Elzaki, Sultan Abdulwadoud Alshoabi, Kamal Dahan Alsultan, Amel F. Alzain, Awatif M. Omer, et al.

    Effective control of healthcare-associated infections (HAIs) involves a collaborative effort among various healthcare stakeholders, including healthcare workers, patients, and professionals. Radiographers, as essential members of the healthcare team, play a crucial role in HAI prevention by diligently adhering to standard infection control precautions (SICP) and maintaining a high level of knowledge regarding infection control procedures. The study aimed to assess the knowledge and practice of radiographers concerning infection control in radiology departments in Saudi Arabia. Methods: A descriptive cross-sectional study was conducted in Saudi Arabia in the period from February to May 2022, with data collected using an online survey in the form of a google forms questionnaire disseminated through social media as an electronic link and including the patient’s demographic characteristic such as age, gender, education level, experience, and prior infection control training and multiple closed ended questions to assess knowledge of standard infection control precautions and the practice of infection control. Overall, 113 participants responded to the survey and entered their responses directly, and the data were analyzed using the SPSS (statistical package for social science). Results: The study revealed that the mean score of knowledge and awareness of the practice of infection control among radiographers in Saudi Arabia was (63.0 and 61.9, respectively), which were considered moderate levels. Females were significantly more knowledgeable about infection control and more aware of the practice than males (p-values = 0.019). The participants who previously attended courses of infection control training had a significantly higher score with a mean rank of (60.9) than those who had not (43.4), (p-value = 0.013). The radiographers’ level of experience, age, and academic qualification had no significant influence on overall knowledge and practice of infection control (p-values > 0.05). Conclusions: In Saudi Arabia, radiographers have a moderate level of knowledge and practice of infection control. There is a need for an ongoing training and education program for practicing radiographers to ensure they perform better in infection control measures.


  • Top Cited Papers
    Open Access

    Hydatid Disease: A Radiological Pictorial Review of a Great Neoplasms Mimicker

    by Sultan Abdulwadoud Alshoabi, Abdulaziz H. Alkalady, Khaled M. Almas, Abdullatif O. Magram, Ali K. Algaberi, Amal A. Alareqi, Abdullgabbar M. Hamid, Fahad H. Alhazmi, Abdulaziz A. Qurashi, Osamah M. Abdulaal, et al.

    Hydatid cyst is a common name for the larval stage of a tapeworm species of Echinococcus granulosus, which is transmitted from animals to humans via the fecal–oral route. Hydatid cysts predominantly affect the liver (75%), followed by the lung (15%), and they can affect many organs in the human body. Medical imaging modalities are the keystone for the diagnosis of hydatid cysts with high sensitivity and specificity. Ultrasound imaging with high resolution is the first choice for diagnosis, differential diagnosis, staging, establishing a role in interventional management, and follow-up, and it can differentiate Type I hydatid cysts from simple liver cysts. Unenhanced computed tomography (CT) is indicated where or when an ultrasound is unsatisfactory, such as with chest or brain hydatid cysts, when detecting calcification, and in obese patients. Magnetic resonance imaging (MRI) is superior for demonstrating cyst wall defects, biliary communication, neural involvement, and differentiating hydatid cysts from simple cysts using diffusion-weighted imaging (DWI) sequences. According to the phase of growth, hydatid cysts occur in different sizes and shapes, which may mimic benign or malignant neoplasms and may create diagnostic challenges in some cases. Hydatid cysts can mimic simple cysts, choledochal cysts, Caroli’s disease, or mesenchymal hamartomas of the liver. They can mimic lung cystic lesions, mycetoma, blood clots, Rasmussen aneurysms, and even lung carcinomas. Differential diagnosis can be difficult for arachnoid cysts, porencephalic cysts, pyogenic abscesses, and even cystic tumors of the brain, and can create diagnostic dilemmas in the musculoskeletal system.


  • Open Access

    Morphometric Analysis of the Midline Mandibular Lingual Canal and Mandibular Lingual Foramina: A Cone Beam Computed Tomography (CBCT) Evaluation

    by Ahmed Yaseen Alqutaibi, Muath Saad Alassaf, Shadia A. Elsayed, Abdulmajeed Saud Alharbi, Abdulsamad Talaat Habeeb, Marwan Ahmad Alqurashi, Khalid Ahmed Albulushi, Mohamed Omar Elboraey, Kamal Alsultan, Ihab Ismail Mahmoud

    Background: This study aimed to evaluate the midline mandibular lingual canals and foramina and their anatomic variations using CBCT scans. Methods: This study used retrospective analysis. A total of 320 CBCT scans were used to evaluate the study parameters, which comprised the presence or absence of the mandibular lingual foramen (MLF)/mandibular lingual canal (MLC) and its category, the distance between the buccal cortex and the start of the MLC, the distance between the inferior border of the mandible and the superior border of the foramen at its lingual and buccal terminals. The length and diameter of each canal at its lingual and buccal terminals. Results: MLC was found in all included CBCT scans. Out of 320 included CBCT scans, a single canal was represented by 30.9%, double canals (Supra with Infra -spinosum) configuration appeared in 54.7%, and triple canals (Supra-Inter-Infra) represented 14.7%. The supraspinosum canals averaged 5.81 ± 2.08 mm in length and 0.87 ± 0.30 mm in diameter at the lingual terminal. In terms of the number of canals, there was a significant difference between men and women (p ≤ 0.001), with 60% of the men in the sample having double canals and 43.1% of the women having single canals. Moreover, the male gender had a higher prevalence of triple canals (21.3% vs. 8.1%) than females. Males and females were distributed equally among the supraspinosum canals, with no statistically significant difference (p ≤ 0.7). A considerable increase in the finding of interspinosum and infraspinosum canals was seen in the male sample (p ≤ 0.001). Conclusions: midline mandibular canals were found in all investigated CBCTs of the sample of both sexes; however, the anatomy and location of the MLF and canals varied significantly among the Saudi population.