Reproducibility of Ventricular Fibrillation Characteristics in Patients Undergoing Implantable Cardioverter Defibrillator Implantation
Authors:
- Michelle A. ParkerMPMichelle A. Parker
- Dave JohnsonDJDave Johnson
- Nikki RobinsonNRNikki Robinson
- Alan H. KadishAKAlan H. Kadish
- 1 November 1997
- journal article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 8 (11) , 1209-1217
Abstract
Reproducibility of VF Characteristics. Introduction: The purpose of this study was to evaluate the immediate reproducibility of local electrogram characteristics recorded during repeated episodes of induced ventricular fibrillation (VF) in patients undergoing implantable cardioverter defibrillator (ICD) implantation. Methods and Results: Power spectral analysis (using a fast Fourier transform algorithm) of electrograms recorded during 3 seconds of VF were analyzed in 24 patients undergoing ICD implantation using a Medtronic Transvene lead. Patients had 2 to 7 episodes of VF that were induced during defibrillation threshold testing. VF was induced by burst pacing (n = 20) or T wave shock (n = 4). Simultaneous electrograms during VF were recorded from a Medtronic Transvene lead with the following configurations: (1) a narrow spaced (12 mm) dedicated bipole used clinically for sensing; (2) a unipolar electrogram from the right ventricular coil; and (3) a widely spaced (18.3 mm) integrated bipole using the distal tip and the coil. Intraclass correlation coefficients (ICCs) were determined to examine the reproducibility of these VF characteristics among VF episodes in each patient. Recordings from both bipolar configurations had ICCs from 0.40 to 0.55, whereas unipolar recordings ICCs were below 0.40. Reproducibility was similar for dedicated and integrated recordings. Conclusions: Frequency characteristics of repeated episodes of VF induced in the same subjects show fair‐to‐good but not excellent reproducibility. Bipolar recordings were far more reproducible than unipolar recordings, but both bipolar configurations had similar reproducibility. These findings have implications for both the pathophysiology of induced VF and the design of VF detection algorithms.Keywords
This publication has 15 references indexed in Scilit:
- Modifications in the evolution of the dominant frequency in ventricular fibrillation induced by amiodarone, diltiazem, and flecainideJournal of Electrocardiology, 1996
- Analysis of the Body Surface ECG Measured in Independent Leads During Ventricular Fibrillation in HumansPacing and Clinical Electrophysiology, 1995
- Spatial and temporal linking of epicardial activation directions during ventricular fibrillation in dogs. Evidence for underlying organization.Circulation, 1992
- Median frequency — a new parameter for predicting defibrillation success rateAnnals of Emergency Medicine, 1991
- Pharmacological analysis of established ventricular fibrillationBritish Journal of Pharmacology, 1990
- Mechanisms underlying the development of ventricular fibrillation during early myocardial ischemia.Circulation Research, 1990
- Fourier analysis of ventricular fibrillation and synchronization of DC countershocks in defibrillationJournal of Electrocardiology, 1988
- Time Domain and Spectral Analysis of Electrograms in Man During Regular Ventricular Activity and Ventricular FibrillationIEEE Transactions on Biomedical Engineering, 1984
- The transition to ventricular fibrillation induced by reperfusion after acute ischemia in the dog: a period of organized epicardial activation.Circulation, 1981
- Flow of "injury" current and patterns of excitation during early ventricular arrhythmias in acute regional myocardial ischemia in isolated porcine and canine hearts. Evidence for two different arrhythmogenic mechanisms.Circulation Research, 1980