AKAlan H. Kadish

Alan H. Kadish

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alan H. Kadish has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Taresh Taneja

    Division of Cardiology, Northwestern University Medical School, Chicago, Illinois, USA

    2 shared publications
  • Britta Windhagen Mahnert

    Division of Cardiology, Northwestern University Medical School, Chicago, Illinois

    1 shared publication
  • Dave Johnson

    1 shared publication
  • George Horvath

    Division of Cardiology, Department of Medicine and the Feinberg Cardiovascular Research Institute, Northwestern University, Chicago, Illinois

    1 shared publication
  • Jeffrey Goldbbrger

    Division of Cardiology, Department of Medicine and the Feinberg Cardiovascular Research Institute, Northwestern University, Chicago, Illinois

    1 shared publication
  • Jeffrey Goldberger

    Division of Cardiology, Northwestern University Medical School, Chicago, Illinois

    1 shared publication

Latest Publications

  • Effects of Sex and Age on Electrocardiographic and Cardiac Electrophysiological Properties in Adults

    by Taresh Taneja, Britta Windhagen Mahnert, Rod Passman, Jeffrey Goldberger, Alan Kadish

    TANEJA, T., et al.: Effects of Sex, and Age on Electrocardiographic and Cardiac Electrophysiological Properties in Adults. Although differences in patient sex in heart rate and QT interval have been well characterized, sexual differences in other cardiac electrophysiological properties have not been well defined. The study population consisted of 354 consecutive patients without structural heart disease or preexcitation who underwent clinically indicated electrophysiological testing in the drug‐free state. Atrial, AV nodal, and ventricular effective refractory periods (AERP, AVNERP, VERP) were determined at a pacing cycle length of 500 ms using an 8‐beat drive train and 3‐second intertrain pause. There were 124 men and 230 women with a mean age of 45 ± 19 and 47 ± 18 years, respectively The sinus cycle length (SCL) was longer in men than in women (864 ± 186 and 824 ± 172 ms, respectively, P < 0.05). The QRS duration was significantly longer in men (90 ± 12 ms) than women (86 ± 13 ms) (P < 0.005). The HV interval was 48 ± 9 ms in men and 45 ± 8 ms in women (P < 0.05). The sinus node recovery time (SNRT) was significantly longer in men than in women (1215 ± 297 ms and 1135 ± 214 ms, respectively, P < 0.05). AERP and VERP were similar in both sexes. Aging did not influence sexual differences in cardiac electrophysiological properties, although, it independently prolonged the SCL, PR, and QT intervals, AH and HV intervals, SNRT, AVNERP, and the AV Wenckebach cycle length. The SCL, QRS duration, HV interval, and SNRT were significantly longer in men than in women. Aging prolonged cardiac conduction and increased the SCL but the effects were similar in both sexes. AERP and VERP were unaffected by aging or sex.


  • Reproducibility of Ventricular Fibrillation Characteristics in Patients Undergoing Implantable Cardioverter Defibrillator Implantation

    by Taresh Taneja, Jeffrey Goldbbrger, Michelle A. Parker, Dave Johnson, Nikki Robinson, George Horvath, Alan H. Kadish

    Reproducibility of VF Characteristics. Introduction: The purpose of this study was to evaluate the immediate reproducibility of local electrogram characteristics recorded during repeated episodes of induced ventricular fibrillation (VF) in patients undergoing implantable cardioverter defibrillator (ICD) implantation. Methods and Results: Power spectral analysis (using a fast Fourier transform algorithm) of electrograms recorded during 3 seconds of VF were analyzed in 24 patients undergoing ICD implantation using a Medtronic Transvene lead. Patients had 2 to 7 episodes of VF that were induced during defibrillation threshold testing. VF was induced by burst pacing (n = 20) or T wave shock (n = 4). Simultaneous electrograms during VF were recorded from a Medtronic Transvene lead with the following configurations: (1) a narrow spaced (12 mm) dedicated bipole used clinically for sensing; (2) a unipolar electrogram from the right ventricular coil; and (3) a widely spaced (18.3 mm) integrated bipole using the distal tip and the coil. Intraclass correlation coefficients (ICCs) were determined to examine the reproducibility of these VF characteristics among VF episodes in each patient. Recordings from both bipolar configurations had ICCs from 0.40 to 0.55, whereas unipolar recordings ICCs were below 0.40. Reproducibility was similar for dedicated and integrated recordings. Conclusions: Frequency characteristics of repeated episodes of VF induced in the same subjects show fair‐to‐good but not excellent reproducibility. Bipolar recordings were far more reproducible than unipolar recordings, but both bipolar configurations had similar reproducibility. These findings have implications for both the pathophysiology of induced VF and the design of VF detection algorithms.