Stress-strain state of the bone-fixator system with a tibial defect under the influence of bending load (sagittal plane)
Open Access
- 10 May 2026
- journal article
- Published by Publishing House Zaslavsky in EMERGENCY MEDICINE
- Vol. 22 (3) , 268-275
Abstract
Background. Segmental defects of the tibia (critical defect: more than 2 cm long and loss of more than 50 % of bone mass) are divided into primary (due to high-energy trauma) and secondary, as a result of radical resection of necrotic and infected bone fragments, resection of bone tumors, etc. Within the framework of biomechanical studies of modern fixators, great attention is paid to the development of structural parameters that influence the stability of the construct, such as rigidity, maximum stress values at the control points of the system and performance of the pin-bone interface. The purpose of the study was to investigate the stress-strain state of a model of the lower leg with a tibial defect with different options for its extra-articular osteosynthesis under the influence of a bending load acting in the sagittal plane. Materials and methods. A defect 5 cm long was modeled in the middle third of the tibia. Stabilization of the tibia with an external fixation device was studied with three options for inserting rods with a diameter of 8 mm at angles of 30, 60, and 90°. Results. Under the influence of bending load in the sagittal plane, insertion of fixing rods at an angle of 30° creates a maximum stress in the bone tissue of 13.4 and 9.4 MPa around distal pair of rods, around proximal one — of 8.4 and 6.6 MPa, respectively; at an angle of 60°, compared to the previous model, it causes an increase in the level of stresses in the bone tissue almost around all fixing rods. Change in the distribution of stresses on the fixing rods inserted at an angle of 90°: on rods 1 and 4, the stress level decreases to 48.4 and 28.0 MPa, respectively, which are the lowest indicators for all previous models. Conclusions. With a bending load acting on the limb in the sagittal plane, the most favorable option for minimizing stresses in the bone tissue is the installation of the external fixation device with the fixing rods inserted at an angle of 30°.Keywords
This publication has 15 references indexed in Scilit:
- Promoting bone generation through the accordion technique in critical-sized bone defects: a reviewInternational Journal of Surgery, 2025
- Pin Site–Related Outcomes After Temporary Staging External Fixator Pin Placement Using the Self-Drilling Pin Insertion TechniqueJournal of Orthopaedic Trauma, 2025
- The effectiveness of resistance to torsional loads of various options for osteosynthesis of bone fragments of the tibia for fractures in the upper third of the diaphysis (mathematical modeling)ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS, 2023
- Ilizarov bone transport using an intramedullary cable transportation system in the treatment of tibial bone defectsInjury, 2021
- A novel low-profile external skeletal fixator for type IIIB open tibial fractures: A biomechanical and clinical pilot studyJournal of the Chinese Medical Association, 2021
- Thermal effects of various drill materials during implant site preparation—Ceramic vs. stainless steel drills: A comparative in vitro study in a standardised bovine bone modelClinical Oral Implants Research, 2020
- Surgical Drill Bit Design and Thermomechanical Damage in Bone Drilling: A ReviewAnnals of Biomedical Engineering, 2020
- Classification of Bone Defects: An Extension of the Orthopaedic Trauma Association Open Fracture ClassificationJournal of Orthopaedic Trauma, 2020
- External fixation of the lower extremities: Biomechanical perspective and recent innovationsInjury, 2019
- Analysis of the External Fixator Pin-Bone InterfaceClinical Orthopaedics and Related Research, 1993