    A comparative analysis of the stress-strain state of a femur model with a revision stem following an extended trochanteric osteotomy depending on the length of the stem

    by V.A. Filipenko, S.YE. Bondarenko, Ye.V. Olinkevich, O.P. Marushchak, M.YU. Karpinsky, O.V. Yaresko

    Background. Removal of a stable femoral component of a prosthesis is one of the most challenging problems in revision hip arthroplasty. An extended trochanteric osteotomy (ETO) provides adequate access to the femoral canal; however, once performed, the question arises as to the choice of length for the revision stem, which must cover the lower edge of the osteotomy without creating excessive stress concentrations in the bone and the fixation elements. The purpose was to conduct a comparative analysis of stress values in a femur model with a revision stem following an ETO, depending on the length of the stem. Materials and methods. A basic finite-element model of the femur was developed with a revision endoprosthesis implanted following an extended proximal osteotomy. Models were created for three variants of the endoprosthesis stem length: 1, 3 and 5 cm below the lower edge of the osteotomy. The bone flap was fixed with a 1.5-mm diameter cerclage wire at two levels, with two turns at each level. The model was loaded with a force of 1100 N applied to the femoral head and a force of 468 N from the hip abductors. Results. The length of the prosthesis stem has virtually no effect on the stress distribution in the bony elements of the models: at the distal end of the diaphysis and in the bone flap, the differences between the models are minimal. The most significant changes are observed in the area of the lower edge of the osteotomy, where, as the stem length increases from 1 to 5 cm, the stress level decreases from 18.9 to 13.0 MPa. Furthermore, a stem that overlaps the lower edge of the osteotomy by 5 cm results in the lowest stress levels in the endoprosthesis neck (148.9 MPa) and the cerclage wire (443.9 MPa); however, the stresses at its distal end increase 15-fold — to 217.7 MPa, which is, nevertheless, 2.5 times lower than the tensile strength of surgical steel. Conclusions. Covering the lower osteotomy zone with a revision stem by 5 cm following the removal of a stable femoral component using an ETO reduces the load on the cerclage wire and decreases stress concentration in the area of the lower edge of the osteotomy. This choice of stem length ensures component stability and offers advantages over the use of shorter revision stems, particularly in complex revision arthroplasty cases.

  • Open Access

    Biomechanical justification of the technology of extra-articular osteosynthesis in tibial defects under the influence of compressive load

    by O.A. Burianov, V.р. Kvasha, Yu.O. Yarmoliuk, M.S. Pasenko, M.YU. Karpinsky, O.V. Yaresko

    Background. Long segmental defects of the tibia can occur as a result of high-energy trauma, radical removal of contaminated bone fragments in an open fracture, resection of a bone tumor, or during treatment of infected areas at the site of nonunion. Full-scale combat operations significantly affected the statistical indicators of tibial defects. Gunshot and mine-explosive injuries, which are characterized by high kinetic energy, have led to an increase in the proportion of primary defects in the long bones of the lower extremities (according to preliminary data, about 11–17 %). Among methods currently used for repairing bone tissue defects, there are the distraction osteogenesis technique, or bone transport, and the Masquelet technique, each of which has its own disadvantages and advantages. Objective of the study: to investigate the stress-strain state of a tibial model with a defect in its middle third, with different options for extra-articular osteosynthesis under the influence of compressive loading. Materials and methods. A defect of 5 cm long was modeled in the middle third of the tibia. Stabilization of the tibia with an external fixation device (EFD) was studied with three options for inserting rods with a diameter of 8 mm at angles of 30, 60, and 90°. A 10-node tetrahedron with quadratic approximation was chosen as the finite element. All materials used in the models were assigned appropriate mechanical properties, such as Young’s modulus and Poisson’s ratio. Results. The stress level reaches a maximum around rods 5 and 3 — 48.0 and 40.6 MPa, respectively. Around frontal screws 1 and 7, in the proximal and distal pairs, respectively, the stress level is significantly lower — 29.8 and 31.9 MPa. The maximum stress level is determined on the rods in the pairs closest to the defect zone, namely in the pair 3 and 4 (320.9 and 272.2 MPa, respectively), 5 and 6 (276.6 and 256.6 MPa). The high stress level on the rods located near the defect zone is also transmitted to the EFD rings to which these rods are attached. Thus, the highest stress level of 243.4 MPa was determined in the lower-middle ring and 239.6 MPa — in the upper-middle one. In the upper and lower rings, stresses are 1.5–2 times lower and are determined at 166.8 and 127.7 MPa, respectively. On the rods that connect the EFD rings to each other, the picture is the opposite. The minimum stress level was determined on the middle rods — 152.3 MPa, the maximum stress level of 340.5 MPa is reached in the rods of the upper section. The stress in the rods of the lower section is 170.9 MPa, half the upper ones, but slightly higher than in the rods of the middle section. Conclusions. Under conditions of vertical compressive load, the most favorable option for minimi­zing stresses in bone tissue is the use of an EFD with insertion of the fixing rods at an angle of 30°. With an increase in the angle between the rods to 60 and 90°, there is a decrease in stresses in the EFD rings; however, this does not compensate for an increase in stresses in the bone tissue and fixing elements. The maximum stress values in all elements of an EFD remain significantly lower than the tensile strength of surgical steel, which indicates a sufficient safety margin of the structure.

  • Open Access

    Stress-strain state of the bone-fixator system with a tibial defect under the influence of bending load (sagittal plane)

    by O.A. Burianov, V.р. Kvasha, M.S. Pasenko, М.а. Zahovenko, M.YU. Karpinsky, O.V. Yaresko

    Background. Segmental defects of the tibia (critical defect: more than 2 cm long and loss of more than 50 % of bone mass) are divided into primary (due to high-energy trauma) and secon­dary, as a result of radical resection of necrotic and infected bone fragments, resection of bone tumors, etc. Within the framework of biomechanical studies of modern fixators, great attention is paid to the development of structural parameters that influence the stability of the construct, such as rigidity, maximum stress values at the control points of the system and performance of the pin-bone interface. The purpose of the study was to investigate the stress-strain state of a model of the lower leg with a tibial defect with different options for its extra-articular osteosynthesis under the influence of a bending load acting in the sagittal plane. Materials and methods. A defect 5 cm long was modeled in the middle third of the tibia. Stabilization of the tibia with an external fixation device was studied with three options for inserting rods with a diameter of 8 mm at angles of 30, 60, and 90°. Results. Under the influence of bending load in the sagittal plane, insertion of fixing rods at an angle of 30° creates a maximum stress in the bone tissue of 13.4 and 9.4 MPa around distal pair of rods, around proximal one — of 8.4 and 6.6 MPa, respectively; at an angle of 60°, compared to the previous model, it causes an increase in the level of stresses in the bone tissue almost around all fixing rods. Change in the distribution of stresses on the fixing rods inserted at an angle of 90°: on rods 1 and 4, the stress level decreases to 48.4 and 28.0 MPa, respectively, which are the lowest indicators for all previous models. Conclusions. With a bending load acting on the limb in the sagittal plane, the most favorable option for minimizing stresses in the bone tissue is the installation of the external fixation device with the fixing rods inserted at an angle of 30°.

  • Open Access

    Experimental study on the stability of osteosynthesis for a fracture of the suprahumeral process and the scapular spine with a bone tissue defect using bone plates

    by O.V. Dolhopolov, S.O. Bezruchenko, R.V. Saliuk, V.L. Suvorov, O.D. Karpinska, M.YU. Karpinsky

    Background. The frequency of scapular fractures in military personnel who were in the combat zone is approximately 20 times higher than among the civilian population. The probable cause of fixation failures is insufficient stability of the structure, especially in cases of bone tissue defect. One of the possible ways to increase the strength of osteosynthesis is the use of two plates located in an orthogonal plane. The purpose was to study in an experiment the stabilizing properties of different variants of osteosynthesis for fragments of a fracture of the suprahumeral process and the scapular spine with a bone tissue defect using bone plates. Materials and methods. The study was performed on anatomical models of the scapula made of high-density polyurethane. To reproduce the fracture, a simulated defect of the suprahumeral process and the scapular spine with a length of 20 mm was created. Two variants of osteosynthesis were studied — with one and two plates (5 samples each). The amount of movement of the scapular fragments under the influence of loading in two planes, vertical and horizontal, was determined. The loading was increased from 0 to 50 N in increments of 10 N. Results. Osteosynthesis of the suprahumeral process of the scapula with one plate provides stable fixation of the fragments only in the vertical plane, when the loading acts perpendicular to the plane of the bone plate. In this case, the displacement of the process is possible only if the metal plate is deformed. Under the influence of the load in the horizontal plane, the largest displacements are noted, since the force acts parallel to the plane of the plate, and the resistance to it is provided exclusively by the fixing screws. Thus, the disadvantage of osteosynthesis with one plate is its effectiveness only in counteracting loads in the vertical plane. The imposition of two plates on the upper and front surfaces of the humeral process ensures stability of the structure both under vertical and horizontal loads. The small difference in the displacement values between these options is due to the geometric features of the plates: the lateral plate had a smaller thickness compared to the upper one, which reduced its resistance to horizontal loads. Conclusions. The stability of the model of fixation for a fracture of the humeral process and the spine of the scapula with a bone tissue defect significantly depends on the configuration of osteosynthesis and the direction of the applied load. Fixation with one plate on the upper surface of the clavicle provides relatively effective resistance to vertical loads, however, with horizontal loading, a significant increase in the movement of fragments is observed, which indicates insufficient rigidity of the structure in this plane. In contrast, fixation with two plates provides significantly smaller movements of the suprahumeral process under loads in both planes, which indicates increased rigidity and stability of the structure.

  • Open Access

    THE INFLUENCE OF HIP ABDUCTORS ON ENSURING POSTURAL BALANCE IN DYSPLASTIC COXARTHROSIS

    by O.E. Oliynik, E.O. Oliynik-Aldushyna, M.YU. Karpinsky, O.D. Karpinska

    Introduction. Dysplastic coxarthrosis disrupts the integrity of the musculoskeletal chain, leading to the development of pathological adaptive responses in patients. Studying the force of muscle contractions in the hip joint region allows the development of clinical and biomechanical models of the patient, facilitates investigation of load-compensation mechanisms, and helps identify potential strategies for influencing adaptive and recovery processes during physical rehabilitation. Aim: to perform mathematical modeling of the contraction force of the hip abductor muscles under conditions of reduced muscle strength and decreased total femoral offset in patients with dysplastic coxarthrosis. Materials and Methods. A mathematical model of hip joint muscle function was developed, taking into account the absolute strength of the muscles, the lever arm length, and the angles of action of the hip abductor muscles. To simulate reduced muscle strength, values that were 25% and 50% lower than the normal level were used. Calculations were performed under conditions of reduced muscle lever arm length (femoral offset) by 5 mm, 10 mm, and 15 mm, and for patient body weights of 70 kg, 100 kg, and 120 kg. Results. A discrepancy between the lever arm length of the hip abductor muscles in a healthy joint and a reduced total femoral offset significantly worsens the mechanical conditions for muscle function. However, a reduction in the total femoral offset of up to 5 mm does not critically affect the efficiency of the hip abductor muscles. The key factor that negatively influences the maintenance of postural balance in dysplastic coxarthrosis is dysfunction of the hip abductor muscles. This condition should be identified and, when possible, corrected prior to surgical intervention during the preoperative preparation for hip arthroplasty through physiotherapeutic interventions. Excess body weight further complicates the function of the hip abductor muscles and, in the presence of muscular insufficiency, has a critical impact on the maintenance of postural balance. As a result, compensatory mechanisms regulating translational balance are activated, which may subsequently lead to pathological changes in the lumbar spine–pelvis–thigh system and contribute to unfavorable early outcomes following hip arthroplasty. Prediction of these changes using a clinical–biomechanical model at the preoperative stage, including timely diagnosis and correction of the identified disorders, allows the physical therapist to develop a controlled rehabilitation program after surgery. Such a program may incorporate monitoring of load distribution both within the entire lumbar spine–pelvis–thigh complex and within its individual components. Conclusions. The most significant factors negatively affecting the function of the hip abductor mechanism are a reduction of the total femoral offset by more than 5 mm, excess body weight, and a preoperative decrease in the strength of muscles responsible for maintaining postural balance. Functional insufficiency of the hip abductor muscles represents the most critical factor impairing postural stability. Therefore, this factor should not only be considered during hip arthroplasty planning but should also be actively addressed during the preoperative stage. Excess body weight further complicates the function of the hip abductor mechanism and, when combined with muscular insufficiency, critically impairs the maintenance of postural balance.

  • Open Access

    Comparative analysis of the stress-strain state of human pelvis models with endoprostheses of different designs after acetabular resection

    by S.YE. Bondarenko, D.B. Vatamanitsa, O.A. Haluzynskyi, M.YU. Karpinsky, O.V. Yaresko, S.V. Burburska

    Background. The widespread introduction of computer planning and 3D printing technologies has opened a new era in the reconstruction of pelvic defects, which allows to ensure maximum anatomical compliance, especially in defects in several segments of the pelvis. Optimization of the implant fit to the bone edges reduces the risk of instability and overloads at the contact points, which improves the long-term stability of the structure. The purpose was to determine the features of stress distribution in human pelvis models with endoprostheses of different designs after resection of the hip socket due to oncological diseases. Materials and methods. A basic finite element model of the human pelvic girdle with femurs was developed, on which 3 options for arthroplasty of the left hip joint were created in conditions of a post-resection segmental defect of the pelvic bones, which violates the integrity of the anterior pelvic ring: 1 — replacement using an endoprosthesis without replacing the defect; 2 — arthroplasty using an endoprosthesis with restoration of the integrity of the pelvic ring; 3 — a model without defects of the pelvic bones with a standard hip joint replacement. The models were loaded with a vertical distributed force of 540 N. The action of m.gluteus medius was simulated with a force of 1150 N and m.gluteus minimus had rigid fixation. Results. When using an endoprosthesis of the hip socket without restoring the integrity of the pelvic ring, the maximum stress level was determined in the superior iliac spine and did not exceed 21.6 MPa. The most stressed element of this type of endoprosthesis is the screws in the iliac flange — 182.3 MPa. At the same time, the stress in the iliac flange itself was observed at a rather low level of 29.0 MPa. The reason for this stress distribution is the cantilevered version of the cup attachment. When using an endoprosthesis that restores the integrity of the pelvic ring, a significant increase in the stress level was observed: in the lesser sciatic notch under the iliac flange of the endoprosthesis — to 79.6 MPa and to 69.0 MPa in the greater sciatic notch. The stress level in the right (intact) pubic bone increased almost 8 times — 33.5 MPa, which is a consequence of the fact that it is the second fixation point of the endoprosthesis. The maximum stress level was determined for the screws in the contralateral pubic bone — 113.4 MPa. But due to the presence of the second attachment point (on the pubic bone), the stresses in the iliac flange screws do not exceed 86.8 MPa. Conclusions. The use of the endoprosthesis without restoring the integrity of the pelvic ring leads to a significant decrease in stresses in the bone elements on the prosthetic side, although it is accompanied by an increase in stresses on the iliac flange screws. Arthroplasty with restoration of the pelvic ring causes a significant increase in stresses in the prosthesis fixation zones, especially in the area of the intact pubic bone, which becomes the second supporting link of the structure. An increase in stresses in the elements of the endoprosthesis and the bone model is associated with the high rigidity and mass of titanium components. According to the criteria of minimizing stresses in the bones and in the endoprosthesis, the option without restoration of the pelvic ring is more favorable.

  • Open Access

    Mathematical modeling of the stress-strain state of the lumbar motion segments in the case of intervertebral disc herniations under different loads

    by A.I. Popov, O.V. Perfiliev, M.YU. Karpinsky, O.V. Yaresko

    Background. The study deals with the mathematical modeling of the stress-strain state of the lumbar motion segments in the case of intervertebral disc herniations under different loads. Objective: to develop and analyze a mathematical model of the stress-strain state of the lumbar motion segments in the case of intervertebral disc herniations under different loads, to determine the patterns of stress and deformation distribution in the fibrous ring and the nucleus pulposus. Materials and methods. A basic mathematical finite element model of the human lumbar spine was developed, which contained the lumbar vertebrae, the sacrum, intervertebral discs and cartilages in the facet joints. Intervertebral discs were modeled from two elements — the annulus fibrosus and the nucleus pulposus. The stress-strain state after discectomy was studied: 1 — discs without damage (normal): 2 — damage to the L4-L5 disc; 3 — damage to the L5-S1 disc; 4 — combined damage to the L4-L5 and L5-S1 discs. The stress-strain state of the models was studied under the influence of a vertical compressive load of 350 N, as well as under the influence of an additional load of 250 N, which simulates the presence of a bulletproof vest, and 500 N, which simulates the full equipment of a fighter. On the caudal surface of the L5 disc, the model had a rigid fixation. Results. Defects in the annulus fibrosus of the intervertebral disc lead to a local increase in stresses in the nucleus pulposus of the damaged segment, regardless of the magnitude of the external load, localization or number of affected discs. Stresses in the nucleus pulposus may exceed physiological values by ≥ 20 times, which explains the mechanism of disc herniation. This allows us to highlight several key aspects. Localized defects in the annulus fibrosus cause critical increases in stresses in the nucleus pulposus, which is the main mechanism of herniation. Accurate mathematical modeling allows us to quantitatively assess the risks and effectively plan the choice of surgical intervention, including decompression and stabilization of segments. Further studies combining clinical observations and numerical modeling are necessary to clarify the mechanisms of load distribution in pathological conditions of the spine and to increase the safety of surgical techniques. Conclusions. Defects of the annulus fibrosus of the intervertebral disc lead to local changes in the stress-strain state, limited to the damaged segments. Even with increased load, the nature of stress distribution between the vertebrae remains stable and does not depend on the localization of the defects. Damage to the annulus fibrosus causes a moderate increase in stresses in the annulus (10–20 % depending on the area) and a significant increase in stresses in the nucleus pulposus — up to 20 times compared to physiological values. In multiple injuries of the intervertebral discs, the intersegmental effect remains minimal, and stresses are concentrated mainly in the area of the immediate defect.

  • Open Access

    Short-segment stabilization techniques for burst fractures of the thoracolumbar junction: a finite element study under lateral flexion

    by Oleksii S. Nekhlopochyn, Vadim V. Verbov, Ievgen V. Cheshuk, Milan V. Vorodi, Michael Yu. Karpinsky, Oleksandr V. Yaresko

    Introduction: Burst fractures of the thoracolumbar junction (TLJ, T10–L2) are common spinal injuries associated with a high risk of neurological complications. Transpedicular fixation is one of the most effective treatment methods; however, the optimal choice of fixation configuration remains unresolved. This study aims to analyze the stress-strain state of various short-segment transpedicular fixation configurations for Th12 vertebra burst fractures under lateral flexion loading. Materials and methods: A finite element model of the Th9–L5 spinal segment with a simulated Th12 burst fracture was created. Four fixation configurations were considered: M1 – short screws in Th11 and L1 (without intermediate screws), M2 – long screws in Th11 and L1 (without intermediate screws), M3 – short screws in Th11 and L1 with intermediate screws in Th12, and M4 – long screws in Th11 and L1 with intermediate screws in Th12. The models were analyzed using CosmosM software, assessing equivalent von Mises stress at 18 control points. Loads simulated physiological lateral trunk bending. Results: Models with long screws (M2, M4) demonstrated lower maximum stresses in connecting rods (315.5–321.0 MPa) compared to short screws (324.8–324.9 MPa). The inclusion of intermediate screws (M3, M4) significantly reduced stress in the fractured Th12 vertebra (by up to 28%), in adjacent vertebral endplates (by 18–25%), and at screw entry points into vertebral arches (up to 28%). The lowest fixation screw stresses were observed in the model with long and intermediate screws (up to 38% lower compared to the baseline model M1). However, intermediate screws minimally influenced stresses in the connecting rods (up to 1.2%). Conclusions: The optimal short-segment transpedicular fixation configuration is the use of long screws in adjacent vertebrae combined with intermediate fixation in the fractured vertebra (M4). This approach provides optimal load distribution, reduces the risk of construct failure, and preserves mobility of adjacent segments. Long screws improve overall system stiffness, while intermediate screws effectively stabilize the damaged segment and significantly unload critical areas of the construct and adjacent anatomical structures.


  • Open Access

    Stress-strain state of a thoracolumbar spine model with a Th12 type A1 vertebral fracture under short-segment pedicle fixation: analysis of compressive loading

    by O.S. Nekhlopochyn, V.V. Verbov, Ye.V. Cheshuk, M.YU. Karpinsky, O.V. Yaresko

    Background. Fractures of the thoracolumbar junction (Th11-L2) are among the most common spinal injuries and frequently lead to post-traumatic deformities and neurological complications. The most widespread surgical treatment is short-segment pedicle fixation; however, questions remain regarding the necessity of including the fractured vertebra in the construct and the optimal screw length. Objective: to evaluate the stress-strain state of the thoracolumbar spine with a Th12 vertebral body fracture of type A1 according to the AO Spine classification, and to determine the influence of the main pedicle screw length and the presence of intermediate screws in the fractured vertebra during short-segment fixation. Materials and methods. A three-dimensional finite element model of the thoracolumbar spine (Th9-L5) was constructed based on computed tomography data. A type A1 Th12 vertebral body fracture (AO Spine classification) was simulated. Four short-segment pedicle fixation configurations were analyzed: short screws without intermediate screws; long screws without intermediate screws; short screws with intermediate screws in the Th12 vertebral body; long screws with intermediate screws in the Th12 vertebral body. An axial compressive load of 350 N was applied. Stress distribution was analyzed using the finite element method accor­ding to the von Mises criterion. Results. The distribution of stresses in the vertebral bodies showed only minor variations (2–3 %) across the models. The basic four-screw construct provided sufficient unloading of the fractured vertebra. Adding intermediate screws reduced stress in the main screws, particularly at Th11, but doubled stress levels in the supporting rods. The use of long bicortical screws exerted a moderate unloading effect on the bony structures but increased stress within the screws themselves, especially at L1. Conclusions. In cases of type A1 compression fractures requiring surgical management, short-segment four-screw fixation ensures adequate spinal stability while minimizing the mechanical load on the fractured vertebra. The use of long screws and additional intermediate screws is more appropriate for severe injuries, whereas in simple compression fractures such modifications do not offer significant biomechanical advantages but increase surgical invasiveness.

  • Open Access

    Experimental study of the stability of osteosynthesis of the clavicle with bone plates in case of a fracture of its suprahumeral end with a bone tissue defect

    by O.V. Dolhopolov, S.O. Bezruchenko, V.V. Zinchenko, V.L. Suvorov, O.D. Karpinska, M.YU. Karpinsky

    Background. Combat injuries of the suprahumeral region with clavicle fractures differ significantly from peacetime injuries. The most common approach to the treatment of clavicle nonunion is open reduction with fixation with a plate located on the upper surface of the bone, in combination with bone grafting. However, according to long-term studies, the frequency of nonunion remains at the level of 3.1–10.5 %. Objective: to study the stabilizing possibilities of the options for osteosynthesis of clavicle fragments in case of a fracture at the border of the diaphysis and the suprahumeral end with a bone tissue defect. Materials and ­methods. The stabilizing possibilities of osteosynthesis of the clavicle with bone plates were studied in case of a fracture at the border of the diaphysis and the suprahumeral end of the clavicle with a 2 cm defect, which was filled with a graft of the appropriate size and fixed with screws. Two options for osteosynthesis of the clavicle were considered: with one plate and two plates, 5 samples in each group. There was determined the value of fragment movement under the influence of bending load in two planes — vertical and horizontal. The load was increased from 0 to 50 N in steps of 10 N. Results. Osteosynthesis of the clavicle with one plate provides stable fixation of fragments only in the vertical plane, when the load acts on its suprahumeral end perpendicular to the plane of the bone plate. In this case, in order to displace the suprahumeral end, the clavicle is forced to deform a metal bone plate, which has significant strength properties. Under the influence of a load in the horizontal plane, the highest rates of movement of the suprahumeral end of the clavicle were observed. This is due to the fact that the load acts parallel to the bone plate and the resistance to the load is provided only by its fixing screws, which turns out to be insufficient. Therefore, the disadvantage of osteosynthesis with one bone plate is that it effectively counteracts loads only in one plane. Osteosynthesis of the clavicle with two bone plates located in mutually perpendicular planes ensures stability of its suprahumeral end under the influence of both vertical and horizontal loads. A small difference in the rates of movement of the suprahumeral end of the clavicle between the groups tested under the influence of vertical and horizontal loads was caused only by the factor of the geometric parameters of the plates. Conclusions. Osteosynthesis of the clavicle with one plate provides stability of its suprahumeral end only in the vertical plane. Under the influence of large loads acting in the horizontal plane, the displacement of the suprahumeral end of the clavicle can be equal to its diameter in cross section. Osteosynthesis of the clavicle with two plates located in mutually perpendicular planes provides stability of its suprahumeral end regardless of the direction of the load.