Surpass evolve flow diverter in intracranial aneurysms: results from a single-center cohort with extended follow-up
Authors:
Open Access
- 7 July 2026
- journal article
- research article
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 168 (1)
Abstract
Background The Surpass Evolve (SE) is a second-generation flow diverter (FD) designed to improve procedural performance compared with earlier devices. This study aimed to evaluate the angiographic efficacy, safety, and clinical outcomes of SE in a single-center cohort with extended follow-up, comparing it to earlier-generation FDs. Methods We conducted a single-center comparative cohort study including 120 patients with unruptured intracranial aneurysms treated between 2014 and 2023. The prospective SE cohort (n = 67) was compared to a retrospective control cohort (n = 53; Surpass Streamline [SS] and Pipeline Embolization Device [PED]). Primary outcomes were complete aneurysm occlusion, major stroke, in-stent thrombosis, aneurysm enlargement, and unfavorable functional outcome. Secondary analyses included a composite safety endpoint and procedural parameters. Propensity score matching (PSM) was additionally performed to adjust for baseline imbalances, while multivariate Cox regression was used in the entire cohort to maximize statistical power. Results Complete occlusion was achieved in 79.1% of the SE cohort, with major stroke and in-stent thrombosis occurring in 1.5% each, and aneurysm enlargement in 3.0%. At last follow-up, 98.5% of SE patients had favorable functional outcomes (mRS 0–2). Compared with controls, the SE cohort had significantly fewer major strokes (1.5% vs. 13.2%, p = 0.029) and lower aneurysm enlargement (3.0% vs. 22.6%, p = 0.002). These findings remained consistent in the PSM-matched cohort, particularly regarding the prevention of aneurysm enlargement (p = 0.012). Procedural time was shorter (p = 0.001), and balloon angioplasty was less frequent (p = 0.023). SE use was independently associated with reduced aneurysm enlargement (adjusted OR, 0.14; p = 0.019). Cox analysis showed SS had lower occlusion probability (HR, 0.58; p = 0.047) than SE, while PED was similar. Conclusions In this single-center comparative cohort, SE demonstrated a favorable safety and efficacy profile, with lower rates of major stroke and aneurysm enlargement and improved procedural efficiency compared with earlier-generation devices.Keywords
This publication has 18 references indexed in Scilit:
- Efficacy and safety of surpass evolve flow diverters: A systematic review and meta-analysisClinical Neurology and Neurosurgery, 2025
- Endovascular Parent Vessel Occlusion Versus Flow Diversion in the Treatment of Large and Giant Aneurysms: A Randomized ComparisonWorld Neurosurgery, 2024
- Evaluation of the Significance of Persistent Remnant Filling and Enlargement After Flow Diversion for Intracranial AneurysmsWorld Neurosurgery, 2024
- Treatment of intracranial aneurysms using the new Surpass Evolve flow diverter: Safety outcomes and six-month imaging follow-upJournal Of Neuroradiology, 2022
- Treatment Outcomes After Single-Device Flow Diversion for Large or Giant AneurysmsWorld Neurosurgery, 2021
- Early clinical experience of using the Surpass Evolve flow diverter in the treatment of intracranial aneurysmsNeuroradiology, 2021
- Initial Experience with Surpass Evolve Flow Diverter in the Treatment of Intracranial AneurysmsClinical Neuroradiology, 2020
- First clinical experience with the new Surpass Evolve flow diverter: technical and clinical considerationsJournal of NeuroInterventional Surgery, 2020
- Predictors of Complications, Functional Outcome, and Morbidity in a Large Cohort Treated With Flow DiversionNeurosurgery, 2019
- Prospective study on embolization of intracranial aneurysms with the pipeline device: the PREMIER study 1 year resultsJournal of NeuroInterventional Surgery, 2019