In vivo determination of root canal length: a preliminary report using the Tri Auto ZX apex‐locating handpiece
Authors:
- 1 July 2002
- journal article
- clinical trial
- Published by Wiley in International Endodontic Journal
- Vol. 35 (7) , 590-593
Abstract
Aim The aim of this study was to assess the clinical perfomance of a cordless handpiece with a built‐in apex locator – the Tri Auto ZX – designed for root canal preparation with nickel‐titanium rotary files. Methodology Twenty‐five human maxillary incisor and canine teeth scheduled for extraction with mature apices were selected for the study. Informed written consent was obtained from each patient before treatment. After administration of local anaesthesia, the teeth were isolated and the pulp cavities accessed. The Tri Auto ZX along with a size 15 K‐file was used in its electronic apex locating function based on the manufacturer's recommendations. A periapical radiograph with the file at the electronically determined constriction was taken, the file removed and the measurement registered as the electronic length (EL). To test the auto reverse function, a size 20 ProFile .04 taper NiTi rotary instrument was mounted in the handpiece. The point for the auto apical reverse function was preset on the panel at the 0.5 mm level. After the file was introduced into the canal and reached the predetermined level, the file automatically stopped and rotated in the opposite direction. A reference point was marked and this measurement was registered as the auto reverse length (ARL). All measurements were made twice by two different investigators. Teeth were then extracted and immersed in a 20% formalin solution for 48 h. After fixation, a size 15 file was inserted into the canal to measure the actual root canal length from the same reference point obtained with the Tri Auto ZX to the apical foramen, as seen in the stereo microscope. When the file tip was visible at the anatomical end of the canal it was withdrawn 0.5 mm and this measurement was registered as the actual length (AL). All measurements were expressed in mm and the measuring accuracy was set to 0.5 mm. The significance of the mean differences between EL and ARL and between EL and AL measurements at the 5% confidence level was evaluated. Results EL measurements were coincident to ARL in all instances. EL and ARL were coincident to AL in 10 (40%) canals, in the remaining 15 canals (60%) the AL measurements were longer than EL and ARL (+0.5 mm) in 14 instances and shorter (–0.5 mm) in one case. Overall, the AL was longer than the EL or ARL, the mean difference being –0.23 mm ± 0.32 (P < 0.05). Conclusions It was concluded that the Tri Auto ZX was useful and reliable. The Tri Auto ZX measurements protected against overpreparation.Keywords
This publication has 14 references indexed in Scilit:
- Apical extent of rotary canal instrumentation with an apexlocating handpiece in vitroOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 1998
- A new engine-driven canal preparation system with electronic canal measuring capabilityJournal of Endodontics, 1997
- Electronic length measurement using small and large files in enlarged canalsInternational Endodontic Journal, 1996
- Determination of location of root perforations by electronic apex locatorsOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 1996
- New electronic canal measuring device based on the ratio methodJournal of Endodontics, 1994
- An in vivo evaluation of Endex electronic apex locatorJournal of Endodontics, 1993
- Accuracy of an electronic apex locator under controlled clinical conditionsDental Traumatology, 1985
- A clinical evaluation of electronic root canal measurementOral Surgery, Oral Medicine, Oral Pathology, 1974
- Biologic aspects of endodonticsOral Surgery, Oral Medicine, Oral Pathology, 1973
- Microscopic investigation of root apexesThe Journal of the American Dental Association, 1955